Philips C5-2 Convex Ultrasound Probe W/ Cartridge Connector | For Parts ~ 39214
Product details
Manufacturer | Philips |
Item: | Philips C5-2 Convex Ultrasound Probe W/ Cartridge Connector – Half Sector Failure – For Parts/Repair |
Model/Cat # | C5-2 | 453561465281 |
Serial No. | B020ZV |
Made In: | USA |
Date of Manufacture: | N/A |
Short Description:
Philips C5-2 convex array ultrasound probe tested on a compatible ultrasound platform. Probe initializes and produces partial imaging; however, significant sector dropout is present. Being sold strictly for parts or repair.
Condition Summary:
Probe Housing & Lens:
Probe head and handle are in good cosmetic condition. No cracks observed. Acoustic lens is smooth and intact.
Cable:
Approximately 8 ft cable. No cuts, tears, or exposed wiring observed. Strain relief is intact.
Connector:
Cartridge-style connector. Crack noted on connector housing. Pins appear intact; however, structural compromise may affect signal transmission.
Functionality / Testing Summary:
Air Scan:
Image is generated; however, complete loss of signal across approximately 50% of the sector (right side) is observed, indicating major element/channel failure.
Phantom Scan:
Findings are consistent with air scan — persistent right-side dropout, confirming the issue is not environmental but internal to the probe.
Body Scan (Abdominal – RUQ):
Probe demonstrates penetration and tissue visualization on the left side only. The right half of the imaging field remains absent, significantly limiting diagnostic usability.
Vascular Scan (Color Doppler – Carotid):
Color Doppler function is responsive on the active portion of the array. However, flow mapping is restricted to the left half, with complete signal absence on the right.
Professional Functional Assessment:
The probe is recognized by the system and partially functional; however, it exhibits a uniform half-sector dropout across all imaging modes. This pattern is highly suggestive of:
- Array element failure (group/channel failure) and/or
- Connector-related signal loss due to observed housing damage
The defect is consistent, reproducible, and independent of scanning conditions.
Unit does not meet clinical performance standards
Not suitable for patient use
Intended strictly for parts, repair, or technical evaluation
- Philips C5-2 Ultrasound Transducer Probe
- Ultrasound system
- Storage case
- Consumables or accessories
Comments
Please enlarge and zoom in on all images for accurate visual inspection. All photos form part of the item description.
Questions / Concerns
If you have any questions or require clarification, please use the “Ask a Question” option before bidding.
Condition: Parts / Repair
- Overall Condition: As shown in the images - AS IS
- Physical Condition: Please carefully review all images before buying -Fair
- Working Condition:Array element failure (group/channel failure).....Item will be received exactly as pictured and is offered AS IS.
Completeness:
The item includes only what is shown in the pictures. Nothing more, nothing less. Please review images and description carefully before purchasing.