2009 Neoprobe GDS 2300 Gamm...

2009 Neoprobe GDS 2300 Gamma Detection System Console Bluetooth Enabled ~ 39282

Item specifics

Condition
Used
Seller Notes
“Pre‑owned Neoprobe GDS Model 2300 Gamma Detection System console with hospital‑grade power cord, Bluetooth interface, and intact housing. Unit powers on, completes startup self‑test, and displays properly."
Model
2300
MPN
2300

More details


$363.20

39282

1 item in stock

Warning: Last item in stock!

Add to cart

Place an offer

Product details

Manufacturer

Neoprobe Corp 

Item:

2009 Neoprobe GDS 2300 Gamma Detection System Console Bluetooth Enabled

Model/Cat #        

GDS 2300

Serial No.        

094265439 

Made In:             

USA

Date of Manufacture:  

2009

Voltage:                   100–240V | 50–60Hz | 26W Fuse: T1.6A/250V

Short Description:

Neoprobe GDS Model 2300 Gamma Detection System console. Sale is for console with hospital-grade power cord only. No probe available for testing.

Condition Summary:

  • Cosmetic Condition: Unit is in very good overall cosmetic condition. Housing is clean with only minor signs of use. No dense cracks or major damage observed.
  • Front Panel: Display window is intact with visible illumination. All buttons and control knob are present and appear intact. Labels remain clear.
  • Rear Panel: Ports and connectors are intact. Cooling vents are clean. Unit shows Bluetooth labeling/interface, indicating Bluetooth-equipped configuration.
  • Structure: Base and housing are structurally sound.
Functionality / Testing Summary:
  • Power-On: Unit powers on successfully.
  • Self-Test: Completes the startup sequence without interruption.
  • Display: Screen, indicators, and segments illuminate properly.
  • Startup Message: Unit reaches display reading “nO Linc” (No Link) — consistent with no probe connected.
  • Isotope Modes: Startup screen indicates selectable isotope modes (e.g., Indium, Cobalt, etc.), typical for this system.
  • Controls: Buttons and rotary knob appear responsive during navigation.
  • Testing Limitation: No probe available — no further functional or clinical testing performed.
What Is Included:
  • 2009 Neoprobe GDS 2300 Gamma Detection System Console
  • Hospital-grade power cord
What Is Not Included:
  • Probe
  • Rolling cart
  • Probe storage case(s)
  • User manual
  • PM / calibration records
  • Any additional accessories
Buyer Advisory Note:
Unit was tested to power on and complete its startup sequence only. The “nO Linc” message indicates no probe/link detected. Buyer will need to supply a compatible probe and perform any required calibration and validation prior to use.

Shipping Note:
Unit will be securely packed. Rolling cart is not included.

*Items shown in photos are the items that will ship.  If it is not shown in the photos, it is not included*

Stock ID : 39282 (P.O 2022) (SC 7) 

Comments:

Kindly enlarge the images and see them with zooming.

Concern or query: Ask a Question

Condition: USED, please refer to images for cosmetic condition.

  1. 1.    Overall Condition:- As seen in images  - Very Good
  2. 2.    Physical Condition:  Please review images before bidding : Very Good
  3. 3.    Working Condition: Unit was tested to power on and complete its startup sequence only. The “nO Linc” message indicates no probe/link detected....will receive item as pictured ……………(offered AS IS)
  4. 4.    As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
  5. 5.    Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)