Philips IntelliVue MP70 M80...
Philips IntelliVue MP70 M8007A FMS MMS BIS CO IBP Nellcor SpO2 Monitor ~40800
Item specifics
Product details
Philips IntelliVue MP70 Cardiac Monitoring Platform w/ FMS, MMS, BIS, CO, IBP & Nellcor SpO₂
Item Overview
Pre-owned Philips IntelliVue MP70 Cardiac Physiological Monitoring Platform featuring an MP70 touchscreen monitor, eight-slot Flexible Module Server (FMS), M3001A Multi-Measurement Server (MMS), recorder, BIS, cardiac output, temperature, dual pressure modules, and Covidien/Nellcor OxiMax SpO₂ module.
Supports ECG/RESP, NIBP, SpO₂, temperature, IBP, cardiac output, and BIS monitoring.
All installed modules are recognized by the system. Selected monitoring functions tested.
Stock ID: 40800
Device Information
Philips IntelliVue MP70 Monitor
Model: M8007A | S/N: DE35023608 | DOM: 09/2004
Software: K.21.61 | Configuration P/N: S-M4046-1601A
Options: H40, A08, C01, C02, C05, C07, C15, C20
Connectivity: Rear portal and additional MMS connection
Philips Multi-Measurement Server (MMS)
Model: M3001A | REF: 862442 | S/N: DE9070C5BP
DOM: 04/2013 | Options: A01, C06
Parameters: ECG/RESP, NIBP, Nellcor FAST SpO₂, temperature, pressure
Installed Modules — Model / Serial Number / DOM
Recorder: M1116B | 4227A49035 | 07/2006
BIS: M1034A | DE11005778 | 08/2005
HP Cardiac Output: M1012A | 3120A07506 | Made in USA
Temperature: M1029A | 3805G95418 | 03/2008
Pressure Module 1: M1006B | DE805A0356 | 12/2000
Pressure Module 2: M1006B | DE805A0366 | 12/2000
Covidien/Nellcor OxiMax SpO₂: REF 10076644 | 561314A741 | 2013
Condition & Inspection
Monitor: Very good cosmetic condition with no noticeable dents or cracks. Bright, clear LCD without noticeable scratches. Touchscreen calibrated and responsive. Navigation knob, controls, rear connectors, and mounting provisions intact.
FMS & Modules: Eight-slot FMS, MMS, and mounting assembly in good used condition. Module housings and mounting plates intact. All installed modules recognized and displayed.
Cosmetic Note: BIS module has a different-color replacement faceplate instead of its original yellow faceplate.
Functional Testing
Tested / Verified
Monitor powers on; touchscreen and controls responsive.
FMS/MMS communication and all module recognition verified.
ECG waveform display, NIBP, SpO₂, and temperature checked.
Nellcor FAST SpO₂ through MMS checked and working.
Covidien/Nellcor OxiMax SpO₂ module checked and working.
Recorder operational; paper not included.
Monitoring profiles, layouts, and equipment menus accessible.
Not Functionally Verified: Cardiac output, IBP measurements, BIS measurements, and other advanced functions not specifically tested.
Included
Equipment: Philips MP70 M8007A Monitor; Eight-Slot FMS; M3001A MMS; M1116B Recorder; M1034A BIS; M1012A HP Cardiac Output; M1029A Temperature; M1006B Pressure Modules (Qty. 2); Covidien/Nellcor OxiMax SpO₂ Module.
New Patient Cables & Accessories — Non-OEM Compatible
SG51245: ECG Patient Cable
SB0411: IBP Adapter Cable, Medex/Abbott
SP9325E: Reusable Nellcor OxiMax SpO₂ Sensor
ST1305: Reusable Skin Temperature Probe
SH0910S: Adult Single-Tube NIBP Hose
SC21-11-1: Reusable Adult NIBP Cuff
All patient cables and sensors are new, individually packaged as pictured. One set included.
Additional Accessories: Philips M3081-61603 FMS Interface Cable (REF 453563402731; Made in Romania); new hospital-grade AC power cord; FMS mounting assembly, lower cable/accessory holder, and rear pole clamp.
SpO₂ Configuration: Nellcor FAST through MMS and Nellcor OxiMax through Covidien module; both checked and working. Included SP9325E sensor is OxiMax type.
Mounting: FMS includes MMS mounting assembly, lower cable holder, and rear pole clamp for attachment to a suitable mounting pole. Stand/pole not included.
Not Included
Stand/mounting pole; Nellcor FAST SpO₂ sensor; cardiac output cables/transducers; IBP transducers; BIS cable/sensor; recorder paper; CO₂ or additional modules; consumables, disposables, or accessories not listed.
The actual items pictured and described are the units supplied.
Buyer Advisory
Pre-owned professional medical equipment. All installed modules recognized; selected monitoring functions tested. Cardiac output, IBP, BIS, and other advanced functions unverified. Professional biomedical inspection, calibration, and electrical safety testing recommended before clinical use.
Stock ID: 40800 (P.O. 2026) (WH) (SHPPING READY)