2017 Philips IntelliVue MX800 Monitoring Platform X2 FMS Rack BIS CO SPO2 ~40233
Item specifics
Product details
Philips IntelliVue MX800 Physiological Monitoring Platform w/ X2, FMS, BIS & CO
Item Overview
Pre-owned Philips IntelliVue MX800 physiological monitoring platform with IntelliVue X2, Philips FMS module rack, dual pressure modules, cardiac output, VueLink, Nellcor OxiMax SpO₂, BIS, and recorder module. Includes FMS interface cable and patient accessories. System powers on, communicates with the FMS rack, recognizes installed modules, and was tested as described below.
Device Information
Philips IntelliVue MX800 — REF 865240 • S/N DE50863415 • DOM 2017-09-25 • Software L.01.17
Options H30 • A08 • C01 • C03 • C06 • C09 • C13 • C15 • C19 • C20 • C21 • C50 • C51 • M06 • M20 • Profiles Adult • Pediatric • Baby
Philips IntelliVue X2 — Model M3002A • S/N DE037B4400 • Software H.21.61 • Options C00 • C01 • C13 • C15 • C20 • Battery Installed
Philips FMS Module Rack — Model M8048A • REF 862461 • S/N DE439E5161 • DOM 2017-08-08 • Includes Cable Caddy & Rear Pole Clamp
FMS Interface Cable — P/N 4535643474781 • Model M3081-61626
Installed Modules
M1006B Pressure #1 — S/N DE805G38822 • DOM 11/2003
M1006B Pressure #2 — S/N DE805A10664 • DOM 12/2000
M1012A Cardiac Output — S/N 3121A07500
M1032A VueLink — S/N 4503G54126 • DOM 12/2010
Nellcor OxiMax SpO₂ — Installed and recognized by system
M1034A BIS — S/N DE11015617 • DOM 01/2010
M1116B Recorder — REF M1116B • S/N 4227A49014 • DOM 2006-07
Testing & Condition
- System Recognition — MX800 communicates with FMS rack and recognizes installed modules
- ECG/Respiration — Tested and responsive
- NIBP — Tested and responsive
- SpO₂ — Tested and responsive
- Temperature — Tested and responsive
- IBP/Pressure — Recognized; not independently tested
- Cardiac Output — Recognized; not independently tested
- VueLink — Recognized; not independently tested
- BIS — Recognized; not independently tested
- Recorder — Recognized; not independently tested
- MX800 Display — Bright and clean; no significant scratches noted, although very fine surface marks may be present
- MX800 Housing — Very good overall condition with normal scratches/scuffs from prior use; no major dents or housing cracks noted
- Rear Cable Cover — Intact; connection ports appear in good condition
- X2 Monitor — Powers on and communicates with the system; LCD and controls are in good overall condition with normal cosmetic wear
- X2 Handle — Slightly loose
- X2 Battery — Installed and held charge during testing; actual health/runtime unknown. Overnight charging recommended before evaluation
- FMS Rack & Modules — Good overall cosmetic condition with normal prior-use wear; cable caddy and rear pole clamp intact
The system provides selectable Adult, Pediatric and Baby profiles, and the display can be changed among available screen configurations including Standard, 4 Waves, Horizon, Big Numbers and Multiple Leads. Date/time settings are accessible and can be adjusted as required.
Included
1× Philips IntelliVue MX800 Monitor
1× Philips IntelliVue X2 (M3002A)
1× Philips M8048A / 862461 FMS Module Rack
2× Philips M1006B Pressure Modules
1× Philips M1012A Cardiac Output Module
1× Philips M1032A VueLink Module
1× Nellcor OxiMax SpO₂ Module
1× Philips M1034A BIS Module
1× Philips M1116B Recorder Module
1× FMS Cable Caddy
1× Rear Pole Clamp
1× FMS-to-MX800 Interface Cable – P/N 4535643474781 / Model M3081-61626
1× Power Cord
1× ECG Cable with Patient Leads
1× NIBP Hose with Reusable Adult Cuff
1× Reusable SpO₂ Sensor
1× Skin Temperature Probe
1× IBP Interface Cable (transducer not included)
Not Included
IBP Transducers • Cardiac Output Accessories • BIS Sensors/Interfaces • VueLink Device Interfaces • Additional Modules • Additional Leads • Disposable Sensors/Consumables • Rolling Cart/Stand • User/Service Manuals • PM/Calibration Records • Any Additional Accessories Not Shown or Specifically Listed
Buyer Advisory
Testing was limited to ECG/Resp, NIBP, SpO₂, and Temperature functions. IBP/Pressure, Cardiac Output, VueLink, BIS, and Recorder functions were recognized but not independently verified. No comprehensive biomedical inspection, calibration, or clinical performance testing was performed. Battery health/runtime and PM history are unknown. Buyer/facility should perform appropriate inspection, calibration verification, preventive maintenance, and complete functional testing before clinical use.