Philips IntelliVue MX800 Patient Monitor w/ X2, M3012A CO & 865297 Battery Extension

Item Overview

Pre‑owned Philips IntelliVue MX800 Patient Monitor with IntelliVue X2, M3012A Hemodynamic/Cardiac Output Extension, Philips 865297 Battery Extension, installed batteries, and new compatible non‑OEM patient accessories. System powers on, recognizes attached components, and was functionally tested as described below.


Device Information

Philips IntelliVue MX800

REF: 865240
S/N: DE50839925
DOM: 03/2015
Software: K.21.42
Options: H10 • A08 • C06 • C09

Philips IntelliVue X2

Model: M3002A
S/N: DE95039519
Software: G.01.80
Options: C01 • C12 • C13 • C15 • C20

Philips M3012A Hemodynamic Extension

Product No.: M3012A
S/N: DE34708856
DOM: 03/2006
Option: C05
Configuration: Hemodynamic Monitoring • Cardiac Output Capability

Philips 865297 Battery Extension

REF: 865297
S/N: DE4361612
DOM: 03/2021
Protection: IP32
Installed Battery


Testing & Condition

  • System Recognition — MX800 recognizes X2, M3012A, and Battery Extension
  • ECG/Respiration — Tested and responsive
  • NIBP — Tested and responsive
  • SpO₂ — Tested and responsive
  • Temperature — Tested and responsive
  • IBP / Cardiac Output — Not independently tested
  • MX800 Display — Bright and responsive; multiple cosmetic scratches present
  • Controls & Alarms — Responsive during testing
  • MX800 Housing — Good overall condition with normal prior‑use wear
  • Rear Blue Cover — Missing
  • X2 Condition — Powers on and communicates normally; display has a scratch and slight housing crack near battery‑release area
  • M3012A & 865297 — Very good cosmetic condition
  • Batteries — Held charge during testing; runtime unknown

Included

Philips Equipment

1× Philips IntelliVue MX800 (REF 865240)
1× Philips IntelliVue X2 (M3002A)
1× Philips M3012A Hemodynamic/Cardiac Output Extension
1× Philips 865297 Battery Extension
Installed Batteries
1× Power Cord

New Compatible Non‑OEM Accessories

1× ECG Cable (REF SG5124S)
1× SpO₂ Sensor (REF SP9325)
1× Temperature Probe (REF ST1305)
1× Adult NIBP Cuff (REF SG1711‑11)
1× NIBP Adapter (REF SB04111)
1× NIBP Hose (REF SH0910S)


Not Included

Universal Dock • FMS Rack • Philips Remote Control • IBP Transducers • Cardiac Output Accessories • CO₂ Sampling Lines • Disposable Sensors • Rolling Cart/Stand • User Manual • PM Records • Additional Accessories


Buyer Advisory

Testing was limited to the functions described above. IBP and cardiac output functions were not independently verified. MX800 has multiple cosmetic display scratches and is missing the rear blue cable cover. X2 has a display scratch and slight housing crack near the battery‑release area. Installed batteries held charge during testing; battery health and runtime are unknown. Buyer/facility should perform inspection, calibration verification, and complete functional testing before clinical use.

Stock ID: 40718 (P.O. 2025) (19E) - SHIPPING READY

Purchase Terms & Buyer Protections

Condition & Use Notice

Condition: Overall, cosmetic, and functional condition are described in the listing above; please review all images carefully.
Functionality: Sold as described in the listing, or untested if stated. Biomed evaluation is recommended where applicable.
Included: Only items shown in photographs or specifically stated in the listing are included.
Buyer Responsibility: Buyer is responsible for verifying compatibility, suitability, and obtaining inspection, calibration, maintenance, or service as appropriate prior to use.