For orders, please call: 952-232-5970

$0Checkout 0 Item(s)

MENU

    

2015 Philips IntelliVue MX8...

2015 Philips IntelliVue MX800 865240 X2 M3012A Hemodynamic Module & Leads ~40717

Item specifics

Condition
Used
Seller Notes
“Pre-owned Philips IntelliVue MX800 Patient Monitor with X2 Companion Monitor, M3012A Hemodynamic Module, 865297 Battery Extender/Module Rack, installed batteries, and new compatible patient accessories."
Model
MX800
MPN
865240

More details


$2,208.00

40717

1 item in stock

Warning: Last item in stock!

Add to cart

Place an offer

Product details

Philips IntelliVue MX800 Patient Monitor w/ X2, M3012A & 865297 Battery Extender

Item Overview

Pre-owned Philips IntelliVue MX800 Patient Monitor with X2 Companion Monitor, M3012A Hemodynamic Module, 865297 Module Rack/Battery Extender, installed batteries, and a set of new compatible non-OEM patient accessories. System powers on, recognizes the attached modules, and was functionally tested as described below.

Device Information

Philips IntelliVue MX800: REF 865240 • S/N DE50840087 • DOM 03/2015 • Software K.21.42 • Options H10, A08, C06, C09 • 100–240 VAC, 50–60 Hz, 1.9 A • Made in Germany

Philips X2 M3002A: REF 865039 • S/N DE83605121 • DOM 08/2009 • Options C00, C01, C13, C15, C20 • Battery REF 989803148701

Philips M3012A Hemodynamic Module: REF 862111 • S/N DE45275188 • DOM 07/2016 • Dual IBP / Dual Temperature

Philips Module Rack/Battery Extender: REF 865297 • S/N DE43611599 • DOM 01/2021 • Installed battery

Testing & Condition

  • Power/Modules: Powers on and recognizes attached modules
  • ECG/Respiration: Tested and responsive
  • NIBP: Tested and responsive
  • SpO₂: Tested and responsive
  • Temperature: Tested and responsive
  • IBP: Untested
  • Display: Bright and clear; two deep scratches on LCD
  • Touchscreen/Controls: Responsive; alarms and controls functioned during testing
  • Date/Time: Correct and adjustable
  • Housing: Fair-to-good overall condition with normal prior-use wear; rear blue cover missing
  • Remote Holder: Attached to right side with Velcro
  • X2: Handle and ports intact
  • Batteries: Installed and held charge during testing; health/runtime unknown

Included

Philips Equipment:
1× MX800 Monitor REF 865240 • 1× X2 M3002A • 1× M3012A Hemodynamic Module • 1× 865297 Module Rack/Battery Extender • Installed batteries • Power cord

New Compatible Non-OEM Accessories:
ECG Cable REF SG5124S • SpO₂ Sensor REF SP9325E • Temperature Probe REF ST1305 • Adult NIBP Cuff REF SE1711-11 • NIBP Adapter REF SB0411 • NIBP Hose REF SH0910S

Not Included

Universal Dock • FMS 8-Bay Rack • Philips Remote Control • IBP Transducers • CO₂ Sampling Lines • Disposable Sensors • Rolling Cart/Stand • User Manual • PM Records • Other accessories not shown

Buyer Advisory

Testing was limited to the functions described above; IBP was not tested. Installed batteries held charge, but battery health/runtime is unknown. MX800 has two deep scratches on the LCD and the rear blue cover is missing. Buyer/facility should complete appropriate inspection, calibration verification, and functional testing before clinical use.

Stock ID: 40717 (P.O. 2025) (19E) - SHIPPING READY

Purchase Terms & Buyer Protections

Condition & Use Notice

Condition: Overall, cosmetic, and functional condition are described in the listing above; please review all images carefully.
Functionality: Sold as described in the listing, or untested if stated. Biomed evaluation is recommended where applicable.
Included: Only items shown in photographs or specifically stated in the listing are included.
Buyer Responsibility: Buyer is responsible for verifying compatibility, suitability, and obtaining inspection, calibration, maintenance, or service as appropriate prior to use.