For orders, please call: 952-232-5970

$0Checkout 0 Item(s)

MENU

    

SpaceLabs UltraView SL 9426...

SpaceLabs UltraView SL 94267 Monitor w/ Modules, Cart, Printer & NEW Leads~39973

Item specifics

Condition
Used
Seller Notes
“Pre‑owned SpaceLabs UltraView SL modular patient monitoring system with 94267 monitor, 91387 CPU/rack, 90499 accessory rack, 90496 command module, 91517 CO₂ module, 91482 BIS module, 90449 printer, GCX rolling cart, Dell keyboard/mouse."
Model
SL 94267
MPN
See Below

More details


$915.20

39973

1 item in stock

Warning: Last item in stock!

Add to cart

Place an offer

Product details

SpaceLabs UltraView SL Modular Patient Monitoring System

w/ 94267 Monitor, 91496 Command Module, 91517 CO₂ Module, 91482 BISx Module, 90449 Printer, GCX Cart & NEW CE‑Marked Accessories

New SINO‑K Patient Accessories (Brand New, CE‑Marked)

Brand new, unused, CE‑marked reusable accessories manufactured by SINO‑K Medical Technologies, China:

  • Temperature Probe — REF ST1311
  • SpO₂ Sensor (Nellcor Compatible, Direct Type) — REF SP9327A
  • 5‑Lead ECG Cable (One‑Piece) — REF SG126S
  • Adult NIBP Cuff (25–35 cm) — REF SC1711‑11
  • Adult Single‑Tube NIBP Hose — REF SH1010S

Condition: Brand New • Certification: CE Marked

NEW Computer Peripherals

  • Dell Wired Keyboard
  • Dell Wired Optical Mouse Condition: New, functional

SpaceLabs Modules (Used – Good Condition)

91496 Multi‑Parameter Command Module

Option 1AFRU • SN: 1496‑10330 • SW: V2.02.04 Parameters: ECG, Nellcor SpO₂, Temperature, Adult/Pediatric NIBP Condition: Good; no dents/cracks; ports intact; pull handle intact

91517 UltraView SL CO₂ Module

SN: 1517‑001003 • SW: V1.00.11 Good condition; ports intact; no dents/cracks CO₂ sensor & sampling lines not included

90449 Printer Module

SN: 449‑2204440 • SW: V3.21.05CO Printer functional; displays “Out of Paper”; pull handle intact; paper not included

91482 BISx Module

SN: 1482‑001386 • SW: V1.0013 Recognized by system; displays “Connect BIS Cable”

91387 UltraView SL CPU / Module Rack

Option 271Q06 • SN: 1387‑006945 Good condition; multiple connectivity ports; no dents/cracks

90499 Accessory Module Rack

SN: 499‑008780 Good condition; ports intact; no dents/cracks

SpaceLabs 94267 Patient Monitor

SN: PSC‑14420026B Appears non‑touch; all navigation performed using mouse Screen intact; no cracks or lens damage Connectivity: VGA • DVI • Serial

Power Supplies

SpaceLabs AC Adapter

P/N 119‑0480‑00 • SN 4606013 Input: 100–240V~, 50/60Hz, 3–1.5A • Output: 20V ⎓ 4.5A

Skynet AC Adapter

Model SNP‑A087‑3 • SpaceLabs P/N 010‑1840‑00 • SN 143600096 Input: 100–240V~, 50/60Hz, 3–1.5A • Output: 12V ⎓ 6A

Included: 2 × Hospital‑grade power cords

Mounting & Cables

GCX Poly‑Mount Rolling Cart • Utility basket • Fixed‑tight monitor mount • Pull handle Included cables: VGA • Serial • Ethernet

General Information

  • SpaceLabs Equipment Origin: Germany (CE Marked)
  • SINO‑K Accessories Origin: China
  • Condition: Mixed (Brand New SINO‑K + Used SpaceLabs)
  • Reusable • Non‑Sterile

Cosmetic Condition

System in good pre‑owned condition. Monitor bright with excellent color reproduction; glass intact; no cracks or dead areas. Navigation performed via mouse (touch capability uncertain). Modules clean; no major dents or cracks. CPU/module rack and accessory rack securely mounted. GCX rolling stand solid and stable; utility basket included. Keyboard and mouse are new. All SINO‑K accessories are brand new / unused.

Installed Monitoring Parameters

ECG • RESP • Adult/Pediatric NIBP • SpO₂ (Nellcor Compatible) • Temperature • BIS • CO₂

Functional Testing Performed

Verified: ✔ Power‑on self‑test • ✔ ECG • ✔ SpO₂ • ✔ Temperature • ✔ Keyboard • ✔ Mouse
Not Fully Tested (Missing Accessories): IBP • CO₂ • BIS
Printer: Recognized • Displays “Out of Paper” • No additional faults observed

What Is NOT Included

CO₂ Sensor • CO₂ Sampling Lines • BIS Cable • BIS Sensors • Disposable ECG Electrodes • Disposable NIBP Components • IBP Transducers • IBP Pressure Kits • Additional Temperature Probes • Pediatric Accessories • User Manual • Service Manual • Software Licenses • PM Records • Calibration Certificate • Any accessories not specifically listed

Buyer Advisory

Previously owned medical monitoring system. Basic operational testing completed as described. Several monitoring functions require additional accessories not included. Buyer responsible for installation, calibration, verification, and ensuring compatibility with intended application. Reusable accessories supplied non‑sterile.

Shipping Note

System will be professionally packaged with multi‑layer protective materials. Monitor, racks, and cart may be partially disassembled to reduce shipping risk. Reassembly is straightforward.

Stock ID: 39973 (P.O. 2023) (WH 000) 

Purchase Terms & Buyer Protections

Condition & Use Notice

Condition: Overall, cosmetic, and functional condition are described in the listing above; please review all images carefully.
Functionality: Sold as described in the listing, or untested if stated. Biomed evaluation is recommended where applicable.
Included: Only items shown in photographs or specifically stated in the listing are included.
Buyer Responsibility: Buyer is responsible for verifying compatibility, suitability, and obtaining inspection, calibration, maintenance, or service as appropriate prior to use.