For orders, please call: 952-232-5970

$0Checkout 0 Item(s)

MENU

    

SpaceLabs 94266 Touchscreen...

SpaceLabs 94266 Touchscreen Patient Monitor System w/ Modules, CPU & Cart ~39450

Item specifics

Condition
Used
Seller Notes
“Pre‑owned SpaceLabs 94266 touchscreen patient monitoring system (Germany, 2014) with SL2700 CPU, GCX rolling cart, and multiple installed modules (MMS, CO₂, BIS, printer, accessory rack) plus brand‑new CE‑marked SINO‑K accessories."
Model
94266
MPN
See Below

More details


$736.00

39450

1 item in stock

Warning: Last item in stock!

Add to cart

Place an offer

Product details

SpaceLabs 94266 Touchscreen Patient Monitoring System w/ Modules, GCX Cart & New Accessories

System Overview

Pre‑owned SpaceLabs 94266 touchscreen bedside monitoring system with SL2700 CPU, multi‑parameter capability, CO₂, BIS, integrated recorder, and GCX rolling cart. Unit powers on, passes self‑test, and boots directly into the monitoring interface with Adult & Pediatric modes.

 

Monitor & Installed Modules

Monitor

  • Model: SpaceLabs 94266

  • S/N: PRO04320233

  • Software: V2.03.17

Installed Modules

  • 91496 Multi‑Parameter Module

    • ECG, IBP 1–2, Masimo SpO₂, Temp, Adult/Ped NIBP

    • Software: V2.04.00

  • 91517 UltraView SL CO₂ Module

    • S/N 1517‑003436 • Software V1.00.11

  • 90449 Printer Module

    • S/N 449‑2204426 • Software V3.21.05CO

  • 91482 BISx Module

    • S/N 1482‑001395 • Software V1.0013

  • 91387 SL2700 CPU / Module Rack

    • Option 271Q06 • S/N 1387‑1011869

  • 90499 Accessory Module Rack

    • S/N 499‑008783

Power Supplies

  • SpaceLabs AC Adapter P/N 119‑0480‑00

  • Skynet AC Adapter SNP‑A087‑3 / P/N 010‑1840‑00

  • (2) Hospital‑grade power cords

 

Included Brand‑New SINO‑K Accessories (CE Marked)

  • Temperature Probe (ST1311)

  • IBP Adapter Cable – BD Type (SB0216)

  • Masimo‑Compatible SpO₂ Sensor (SP9327B)

  • 5‑Lead ECG Cable (SG126S)

  • Adult NIBP Cuff 25–35 cm (SC1711‑11)

  • Adult Single‑Tube NIBP Hose (SH1010S)

 

Condition Summary

Cosmetic

  • Very good pre‑owned condition

  • Bright, responsive touchscreen

  • No cracks or dead spots

  • Modules clean; connectors intact

  • CPU & accessory racks secure

  • GCX cart stable; utility basket included

  • All SINO‑K accessories unused

Functional

  • Powers on, passes self‑test

  • Boots to monitoring interface

  • Touchscreen fully responsive

  • Adult & Pediatric modes

  • Alarm, trend, recorder menus accessible

  • Navigation via touchscreen, keyboard, mouse

Verified Parameters

  • ECG

  • RESP

  • NIBP (Adult/Ped)

  • Masimo SpO₂

  • Temperature

  • IBP (1–2)

  • BIS (recognized)

  • CO₂ (recognized)

Modules Recognized

  • BIS: prompts “Connect BIS Cable”

  • CO₂: recognized

  • Printer: “Out of Paper”

Not Fully Tested

  • IBP monitoring

  • CO₂ monitoring

  • BIS monitoring

  • Printer output

 

Included

  • SpaceLabs 94266 Touchscreen Monitor

  • 91496 Multi‑Parameter Module

  • 91517 CO₂ Module

  • 90449 Printer Module

  • 91482 BISx Module

  • 91387 SL2700 CPU / Module Rack

  • 90499 Accessory Module Rack

  • GCX Poly‑Mount Rolling Cart

  • Utility Basket

  • Fixed Monitor Mount

  • DVI, Serial, Ethernet Cables

  • SpaceLabs & Skynet Power Supplies

  • (2) Hospital‑Grade Power Cords

  • All New SINO‑K Accessories Listed Above

 

Not Included

  • CO₂ Sensor / Sampling Lines

  • BIS Cable / Sensors

  • Disposable ECG Electrodes

  • Disposable NIBP Components

  • IBP Transducers / Pressure Kits

  • Extra Temp Probes

  • Pediatric Accessories

  • User/Service Manuals

  • Software Licenses

  • PM Records / Calibration Certificate

  • Keyboard & Mouse

  • Any items not shown

 

Buyer Advisory

Basic operational testing performed (ECG, SpO₂, Temp, touchscreen, module recognition). CO₂, BIS, IBP, and printer output not fully tested due to missing accessories/simulators. A biomedical inspection, calibration, and PM are recommended prior to clinical use.

 

Shipping

Professionally packed with components secured individually. Freight shipping may be required depending on destination.

Stock ID: 39450 (P.O. 2025) (WH104) 

Purchase Terms & Buyer Protections

Condition & Use Notice

Condition: Overall, cosmetic, and functional condition are described in the listing above; please review all images carefully.
Functionality: Sold as described in the listing, or untested if stated. Biomed evaluation is recommended where applicable.
Included: Only items shown in photographs or specifically stated in the listing are included.
Buyer Responsibility: Buyer is responsible for verifying compatibility, suitability, and obtaining inspection, calibration, maintenance, or service as appropriate prior to use.