For orders, please call: 952-232-5970

$0Checkout 0 Item(s)

MENU

    

GE Transport Pro Monitor + ...

GE Transport Pro Monitor + TRAM 451M Masimo Module | ECG NIBP SpO2 Temp ~ 39980

Item specifics

Condition
Used
Seller Notes
“Pre‑owned GE Transport Pro patient monitor (Mexico, DOM Jul 2007, REF 2020155‑002) with TRAM 451M Masimo module supporting ECG, Resp, NIBP, SpO₂, Temp, IBP, and Defib Sync. Condition: good overall, bright LCD, minor wear."
Model
Transport Pro
MPN
2020155-002

More details


$782.40

39980

1 item in stock

Warning: Last item in stock!

Add to cart

Place an offer

Product details

GE Transport Pro Patient Monitor – TRAM 451M Masimo – Adult ICU Configuration

Device Information

  • Manufacturer: GE Healthcare

  • Model: Transport Pro Patient Monitor

  • REF: 2020155-002

  • Serial Number: SCS07321476GA

  • Configuration: Adult ICU

  • Country of Assembly: Mexico

TRAM Patient Module

  • Model: TRAM 451M

  • GE Part Number: 2006171-003

  • Module Housing REF: 2011432-002 Rev. G

  • Serial Number: RT407296766GA

  • Date of Manufacture: July 2007

  • SpO₂ Technology: Masimo SET®

  • Installed Parameters: ECG, Respiration, NIBP, Masimo SpO₂, Temperature, IBP (ART1), Defib Sync

  • Software: TRAM Version 12A.3E.3 (13OCT05)

Software Information

  • Main Software Revision: 2.18 (18APR07)

  • Boot Software: 2.1 (04APR07)

Short Description

Complete GE Transport Pro portable patient monitor with TRAM 451M Masimo multi‑parameter module, interface cable, OEM GE AC power adapter, power cord, and a full set of brand‑new CE‑marked compatible accessories. Unit powers on, passes self‑test, and enters monitoring mode normally. ECG, SpO₂, NIBP, and Temperature were verified during testing.

Condition Summary

Cosmetic Condition

  • Bright, clear LCD with no dead pixels or pressure marks

  • Minor cosmetic wear from normal use

  • Keypad and trim knob fully functional

  • Integrated desk stand and bed hanger present

  • Rear module housing intact but shows cosmetic stress cracks around the TRAM opening (non‑impacting)

Functional Condition

  • Normal power‑on and successful self‑test

  • Boots directly into monitoring mode

  • ECG, SpO₂, NIBP, Temperature tested and functional

  • IBP port present but untested

  • TRAM module communicates properly

  • No operational faults observed

Included Components

  • GE Transport Pro Patient Monitor

  • GE TRAM 451M Masimo Patient Module

  • GE Monitor‑to‑TRAM interface cable

  • OEM GE AC power adapter

  • Power cord

Brand‑New CE‑Marked Compatible Accessories 

  • Reusable Temperature Probe (ST1304)

  • IBP Adapter Cable – Abbott Type (SB0407)

  • Adult Reusable Masimo‑Compatible SpO₂ Sensor (SP9310W)

  • 5‑Lead One‑Piece ECG Cable (ST5112S)

  • Adult Double‑Tube NIBP Hose (SH3931G)

  • Adult Reusable NIBP Cuff 25–35 cm (SC1721‑3232)

Not Included 

  • IBP transducer

  • Disposable ECG electrodes

  • Disposable temperature probe covers

  • User manual

  • Any accessories not listed above

Battery Information

  • Two installed battery packs detected

  • Both report “Unknown / No Comm” in diagnostics

  • Battery performance not verified

  • Batteries included as-is and should be considered for replacement

Quick Condition Snapshot

  • ✔ Good used condition

  • ✔ Bright LCD, no pixel defects

  • ✔ Adult ICU configuration

  • ✔ Passes self-test

  • ✔ ECG / Masimo SpO₂ / NIBP / Temp tested

  • ✔ TRAM 451M communication verified

  • ✔ New CE‑marked accessories included

  • ✔ OEM AC adapter included

  • ⚠ IBP not tested

  • ⚠ Cosmetic stress cracks on rear housing

  • ⚠ Batteries show communication errors

Buyer Advisory

This unit was removed from a working clinical environment and tested as described. Testing was limited to ECG, SpO₂, NIBP, Temperature, system startup, and TRAM communication. IBP was not tested due to lack of a transducer. Cosmetic stress cracks do not affect operation. Batteries are included as installed components only and are not guaranteed. Buyer is responsible for verifying compatibility, calibration, and certification prior to clinical use.

Stock ID: 39980 (P.O. 2019) (OH C1) 

Purchase Terms & Buyer Protections

Condition & Use Notice

Condition: Overall, cosmetic, and functional condition are described in the listing above; please review all images carefully.
Functionality: Sold as described in the listing, or untested if stated. Biomed evaluation is recommended where applicable.
Included: Only items shown in photographs or specifically stated in the listing are included.
Buyer Responsibility: Buyer is responsible for verifying compatibility, suitability, and obtaining inspection, calibration, maintenance, or service as appropriate prior to use.