GE Patient Data Module PDM ...
GE Patient Data Module PDM 2016793‑002R | SPO2 ECG NIBP IBP Temp CO ~ 39476
Item specifics
Product details
DEVICE PROFILE
GE Patient Data Module (PDM) Manufacturer: GE Medical Systems Information Technologies REF: 2016793‑002R (Remanufactured Nellcor PDM) Quantity Available: 7 Units (Sold Individually)
INSTALLED PARAMETERS
- ECG
- Temperature / Cardiac Output
- IBP: P1/P3 & P2/P4
- Nellcor OxiMax SpO₂
- NIBP
- Defibrillation Sync
Additional Features: DINAMAP Compatible • Marquette 12SL Compatible • EKPro™ Arrhythmia Analysis • IPX1 Rated
INVENTORY DETAILS
| Qty | REF | Serial Number | Remanufacture Date |
|---|---|---|---|
| 1 | 2016793‑002R | SA312512308GR | 2012‑12 |
| 1 | 2016793‑002R | SA308429397GR | 2008‑10 |
| 1 | 2016793‑002R | SA310496332GR | 2010‑12 |
| 1 | 2016793‑002R | SA311163857GR | 2011‑04 |
| 1 | 2016793‑002R | SA312479747GR | 2012‑11 |
| 1 | 2016793‑002R | SA311090820GR | 2011‑03 |
| 1 | 2016793‑002R | SA312111629GR | 2012‑03 |
GE Patient Data Module (PDM) with integrated Nellcor OxiMax SpO₂. Supports ECG, Temp/CO, four‑channel IBP, NIBP, and Defib Sync. Seven units available, sold individually. All modules share similar cosmetic condition.
CONDITION SUMMARY
Cosmetic Condition
- Good reusable condition
- Normal scratches/scuffs from prior clinical use
- Some units may show minor cosmetic stress cracks
- Parameter ports clean and intact
- Module release latch functional
- Battery compartment empty
- Rear battery cover missing on all units (cosmetic only)
Functional Condition
- Removed from a working clinical environment
- Not tested by us (no compatible GE monitor available)
- Believed functional based on prior use
- Sold as used medical equipment
INCLUDED
- One (1) GE Patient Data Module (sold individually)
NOT INCLUDED
Battery pack • Rear battery cover • ECG cable • SpO₂ sensor • Temp probe • NIBP hose/cuff • IBP cables/transducers • Defib Sync cable • User manual • Consumables • Any items not listed
QUICK CONDITION SNAPSHOT
✔ Good used condition ✔ 7 units available ✔ Supports ECG, Temp/CO, IBP P1/P3/P2/P4, Nellcor OxiMax SpO₂, NIBP, Defib Sync ✔ Ports clean; latch functional ⚠ Minor cosmetic wear ⚠ Some units with cosmetic stress cracks ⚠ Battery pack & rear cover not included ⚠ Untested (no compatible monitor)
BUYER ADVISORY
Modules were removed from a functioning clinical environment but not tested by us. Expect normal cosmetic wear. No accessories, cables, sensors, or battery components are included. Professional testing, inspection, and calibration are recommended prior to clinical use.
SHIPPING NOTE
Each module is professionally packed with anti‑static protection and secure cushioning for safe transit.
Stock ID: 39476 (P.O. ?) (OH C3)
Purchase Terms & Buyer Protections
Condition & Use Notice
Condition: Overall, cosmetic, and functional condition are described in the listing above; please review all images carefully.
Functionality: Sold as described in the listing, or untested if stated. Biomed evaluation is recommended where applicable.
Included: Only items shown in photographs or specifically stated in the listing are included.
Buyer Responsibility: Buyer is responsible for verifying compatibility, suitability, and obtaining inspection, calibration, maintenance, or service as appropriate prior to use.