For orders, please call: 952-232-5970

$0Checkout 0 Item(s)

MENU

    

Philips IntelliVue MX800 Mo...

Philips IntelliVue MX800 Monitor w/ X2 Monitor M3012A Module, Dock & Leads~39945

Item specifics

Condition
Used
Seller Notes
“Pre‑owned Philips IntelliVue MX800 patient monitor (DOM Mar 2015, Germany) with X2 companion module (DOM May 2016, Nellcor SpO₂, battery installed), M3012A Extension (DOM Jun 2010), and M8040A universal dock."
Model
MX800
MPN
865240

More details


$2,736.80

39945

1 item in stock

Warning: Last item in stock!

Add to cart

Place an offer

Product details

Manufacturer & Item Information

  • Manufacturer: Philips Medizin Systeme

  • Item: 2015 Philips IntelliVue MX800 Patient Monitor w/ X2 Companion Monitor, M3012A Extension Module, Universal Dock & Leads

  • Model / Cat #: MX800 / 865240

  • Serial Number: DE50840056

  • Country of Manufacture: Germany

  • Date of Manufacture: March 2015

  • Power Requirements: 100–240 VAC, 50–60 Hz, 1.9–0.9 A

 

Short Description

This listing includes a Philips IntelliVue MX800 Patient Monitoring System paired with a Philips X2 Companion Module and M3012A Extension Module. The system provides a flexible, integrated monitoring platform suitable for bedside and transport applications, offering stable module communication, responsive touchscreen performance, and smooth data transfer.

The monitor powers on normally, recognizes all installed modules, and supports ECG, SpO₂ (Nellcor), NIBP, IBP, and Temperature monitoring. Compatible reusable accessories are included.

Installed Modules

Philips X2 Companion Module

  • Model: M3002A

  • Software Revision: L.01.06

  • Serial Number: DE575M5817

  • DOM: May 2016

  • Options: C00, C01, C13, C15, C20

  • Parameters: ECG, NIBP, SpO₂ (Nellcor), Temperature, IBP

  • Battery: Ref MED4607 — Battery is holding charge

  • Note: Handle cover is missing

Philips IntelliVue M3012A Extension Module

  • REF: 862111

  • Serial Number: DE83735668

  • DOM: June 2010

  • Parameters: 2× IBP, 2× Temperature

  • Universal Dock / Interface Rack

  • REF: M8040A

  • Lot: 1921

  • Option: A03

  • Included: Cable and pole clamp

 

Software & Connectivity

  • Software Version: SW Rev K.21.42

  • Rear Ports: USB, LAN/Ethernet, RS‑232, Video Out, Expansion Bays, Power Input

 

Condition Summary

Cosmetic Condition

  • Housing free of dents or cracks

  • LCD bright and fully touch‑responsive

  • Deep scratches present on display (see photos)

  • Hard keys, knobs, alarm button, and touchscreen all functional

Functional Testing

  • Unit powers on normally

  • Date correct (time adjustable)

  • Alarms functional

  • Waveforms display correctly

  • User profiles switch properly

  • All modules recognized

 

What’s Included

  • 2015 Philips IntelliVue MX800 Monitor

  • Philips X2 Companion Module

  • Philips IntelliVue M3012A Extension Module

  • Philips IntelliVue Charging / Interface Rack (M8040A)

  • ECG Cable — REF SG51245 (5‑Lead, Philips‑compatible)

  • Reusable SpO₂ Sensor — REF SP9325A (Nellcor‑compatible)

  • Adult Reusable NIBP Cuff — REF SE2711‑11 (35 × 27 cm)

  • Single‑Tube NIBP Hose — REF SH0910S

  • Reusable Skin Temperature Probe — REF ST1305

  • IBP Adapter Cable — REF SB0411 (Medex Abbott compatible)

  • Philips OEM Charger‑to‑Monitor Interface Cable

  • Hospital‑Grade Power Cord

 

What’s Not Included

  • External stand or mounting hardware

  • Disposable items / consumables

  • Additional batteries (beyond installed units; endurance not guaranteed)

  • Printer paper or recording supplies

  • User manuals or calibration documentation

 

Important Note

Only the items shown in the listing photographs are included. If it is not shown, it is not included.

Inventory Reference

Stock ID: 39945 (P.O 2025) (WH104 SC1)

Buyer Information

Please review all listing photographs carefully, as they form an essential part of the item description. For any questions, feel free to contact us prior to purchase.

 

Condition & Testing

Condition: Used

  • Cosmetic condition is accurately shown in the listing photographs.

  • Unit has been inspected and tested as described in this listing.

  • Only the functionality specifically stated in this listing has been verified.

  • Item is sold AS‑IS and may require inspection, calibration, maintenance, or certification prior to clinical use.

  • A qualified biomedical technician should evaluate the equipment before patient use.

Completeness

Only the items shown in the listing photographs and specifically described are included. Accessories, manuals, software, mounting hardware, and consumables not listed are not included.