For orders, please call: 952-232-5970

$0Checkout 0 Item(s)

MENU

    

2012 Philips Intellivue MP3...

2012 Philips Intellivue MP30 Patient Monitor W/ M3001A Module & NEW Leads ~39918

Item specifics

Condition
Used
Seller Notes
“Pre‑owned Philips IntelliVue MP30 patient monitor (DOM Aug 2012, Germany) with M3001A MMS module (DOM Oct 2017), tested and fully functional. Parameters supported: ECG, IBP, Temp, SpO₂ (Masimo), NBP. Printer installed.'
Model
MP30
MPN
862135

More details


$464.80

39918

1 item in stock

Warning: Last item in stock!

Add to cart

Place an offer

Product details

Manufacturer

Philips Healthcare

Item:

2012 Philips MP30 Intellivue Patient Monitor W/ M3001A MMS Module & NEW Leads

Model/Cat #        

MP30 / M8002A 

Serial No.        

DE728A6978

Made In:             

Germany

Date of Manufacture:  

2012-08

Voltage:                  100-240V 50-60Hz 1.8-1.0A


Short Description:

This is a pre-owned Philips Intellivue MP30 (M8002A) Patient Monitor W/ MMS Module & Leads. Tested and fully functional with ECG, IBP, Temperature, SpO₂ (Masimo), and NBP parameters. Includes M3001A MMS module & NEW patient leads. Display is bright and responsive with minor surface scratches; overall cosmetic wear is minimal. Stand, user manual, IBP, and CO₂ accessories are not included. 

Specifications & Condition: 

Software Version: L.01.06
Battery: 1X Installed & charging
Parameters: IBP, Temperature, ECG, SpO2 (Masimo) & NBP
Options: H30, A03, C01, C02, C15, C20
Printer: Installed | Paper NOT included
LCD: Bright & responsive | Has some scratches  
Handle: Intact
Trim Knob: Working
Softpads: Working
Dents or cracks:Cracks noted on the casing; see images
Scratches or scuffs: Yes
Logo Emblem: Intact but chipped at the corner 
Connectivity & ports: LAN port available

Philips M3001A MMS Module:

 

  • Ref: 862442
  • SN# DE6520H050
  • DOM: 2017-10-04
  • Options: A03 | C06 | C12
  • Module has been tested and is functioning properly

 

Included:

 

  • 2012 Philips Intellivue MP30 (M8002A) Patient Monitor
  • Philips M3001A MMS Module | SN# DE6520H050
  • ECG Cable W/ Leads Ref SH5124S (New)
  • Reusable SpO2 Sensor Masimo Ref S09325B (New)
  • NBP Hose Ref SH0910S (New)
  • NBP Cuff Adult Ref SC2711-11 (New)
  • IBP Cable Ref SB0412 (New)
  • Temperature Probe Ref ST1305 (NEW) 
  • Power Cord
Not Included:
  • Stand
  • User Manual
  • CO₂ Cable/Transducers

 

 

*Items shown in photos are the items that will ship.  If it is not shown in the photos, it is not included*

 

Stock ID : 39918 (P.O 4014) (WH104 SCC18)

 

Comments:

Kindly enlarge the images and see them with zooming.

Concern or query: Ask a Question

Condition: USED, please refer to images for cosmetic condition.

  1. 1.    Overall Condition: As seen in images - Good
  2. 2.    Physical Condition: Please review images before bidding - Good
  3. 3.    Working Condition: Has been tested at our end & is in good functionality as shown in the images.....Will receive item as pictured……………(Offered AS IS)
  4. 4.    As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
  5. 5.    Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)