Philips IntelliVue MX800 Pa...
Philips IntelliVue MX800 Patient Monitor w/ X2, FMS Rack, Modules, Leads ~ 39406
Item specifics
Product details
Philips IntelliVue MX800 Patient Monitoring Platform — Professional Device Profile
System Identification
- Manufacturer: Philips Medical Systems
- Main Monitor: IntelliVue MX800
- Model / REF: 865240
- Serial Number: DE50839947
- Date of Manufacture: 03/2015
- Software Revision: K.21.42
- Installed Options: H10, A08, C06, C09
- Country of Manufacture: Germany
- CE Marked: Yes
System Configuration
Complete modular MX800 bedside monitoring platform including touchscreen MX800 main display, Philips FMS 8‑Bay rack, X2 companion monitor/module, IntelliBridge EC10, single‑parameter modules, recorder/printer module, Philips interface cable, and OEM‑compatible patient‑ready accessories.
Short Description
Philips IntelliVue MX800 modular patient monitoring system paired with X2 companion monitor/module, FMS 8‑Bay rack, IntelliBridge EC10, IBP modules, temperature module, cardiac output module, BIS module, recorder/printer module, and included interface/patient cables. System powers on normally, recognizes installed modules, and all major components are in very good overall condition. MX800 LCD is bright and responsive with light surface scratches visible on inspection.
Quick Condition Overview
- Functional Status: Tested & Working
- Cosmetic Condition: Very Good Overall
- Module Recognition: All installed modules recognized
- LCD Condition: Bright, responsive; light surface scratches
- Completeness:MX800 platform with X2, FMS rack, modules, cables, and leads
Detailed Condition Summary
Main Monitor Housing
No cracks, dents, or broken plastics. Rear blue cable cover intact. Handle/mounting area secure.
LCD & Touchscreen
Bright, responsive touchscreen. Light surface scratches present; no deep marks, cracks, or dead pixels.
Controls & Navigation
Hard keys, alarm button, rotary knob, and touchscreen navigation all tested and functioning properly.
FMS 8‑Bay Rack
REF: 862461
S/N: DE439D1767
DOM: 03/2015 Rack in excellent structural condition with intact ports, functional connectors, cord caddy, and pole clamp.
X2 Companion Monitor / Module
Model: M3002A
REF: 865039
S/N: DE575M4980
DOM: 04/2016
Software: L.01.06
Installed Options: C00, C01, C13, C15, C20 Good cosmetic condition; LCD responsive. Battery installed and holding charge (long‑term health not evaluated).
Single‑Parameter Modules
All modules in very good condition with intact ports and release latches. Minor signs of normal clinical use only.
Functionality & Testing Summary
- MX800 powers on normally; date/time adjustable
- Alarms functional; waveforms display correctly
- Profiles verified: Adult, Pediatric, Neonatal/Baby, Comfort
- Screen layouts verified: Dynamic Waves, 8/6/4 Waves, Multiple Lead, Overlap Waves, Horizon, Big Numbers, Monitor at Desk, Visitor Clock
- Parameters recognized: ECG/Resp, NIBP, Masimo SpO₂, Temperature, IBP, CO₂, Cardiac Output, BIS
- Rear ports intact: USB, LAN, RS232, Alarm Port, Video Out, Expansion Bays, Power Input
Module‑Specific Testing
M1006B IBP Modules ×2
S/N DE805F0446 (DOM 03/2003)
S/N DE805G5910 (DOM 12/2003) Both recognized; IBP ports intact.
M1029A Temperature Module
REF M1029A, S/N 3805G71802, DOM 11/2003 Recognized; port intact.
M1012A Cardiac Output Module
REF 862279, S/N 3805G25321, DOM 09/2003 Recognized; advanced CO testing not performed.
M1034B BIS Module
S/N DE11007038, DOM 02/2006 Recognized; advanced BIS testing not performed.
M1116B Recorder / Printer Module
S/N 4227A49024, DOM 07/2006 Paper installed; module recognized (print test not performed).
IntelliBridge EC10
REF 865115, S/N DE31719889, DOM 03/2015 Ports intact; recognized by system.
Included Components
- Philips IntelliVue MX800 Main Monitor — REF 865240
- Philips FMS 8‑Bay Rack — REF 862461
- Philips X2 Companion Monitor / Module — M3002A / REF 865039
- Philips IntelliBridge EC10 — REF 865115
- Philips M1006B IBP Modules ×2
- Philips M1029A Temperature Module
- Philips M1012A Cardiac Output Module
- Philips M1034B BIS Module
- Philips M1116B Recorder / Printer Module
- Philips M3081‑61603 Interface Cable
- 5‑Lead ECG Cable — REF SG51245
- Reusable Masimo‑Compatible SpO₂ Sensor — REF SP9325A
- Adult NIBP Cuff — REF SE1711‑11
- NIBP Hose — REF SH0910S
- Reusable Temperature Probe — REF ST4305
- IBP Adapter Cable — REF SB04111
- Hospital‑Grade Power Cord
Not Included
Rolling cart/stand, IBP transducers, CO₂ sampling lines, CO cables/transducers, BIS sensors/cables, additional cuffs, disposable sensors, pediatric/neonatal accessories, extra modules, user manuals, PM/service records, calibration documentation.
Buyer Advisory
This is used hospital‑surplus equipment and may show minor cosmetic wear such as light scratches or label residue. MX800 LCD has visible surface scratches. Some modules were partially untested due to unavailable disposables or specialty accessories. Buyer should verify compatibility with their clinical environment prior to purchase.
Shipping Information
System will be professionally packed for safe transport. Due to size and modular configuration, freight or oversized shipping may be required depending on destination.
Stock ID: 39406 (P.O. 2025) (WH104 SC3)