Philips IntelliVue MX800 Patient Monitoring System – Fully Configured & Tested
Overview
This listing is for a Philips IntelliVue MX800 Patient Monitoring Platform configured with an IntelliVue X2 companion monitor, M3001A Multi‑Measurement Server (MMS), M3015A Hemodynamic/CO₂ extension module, universal docking station, coiled remote, OEM Philips interface cable, hospital‑grade power cord, and a complete set of new OEM‑compatible accessories. The system supports adult, pediatric, and neonatal monitoring profiles and has been fully tested for core functionality.
System Components
Philips IntelliVue MX800 Monitor
- REF 865240 | S/N DE50863405
- Date of Manufacture: 2017‑09‑25
- Software Revision: L.01.17
- Installed Options: J20, A00, C01, C03/C05, C06, C09, C13, C14, C19, C20, C21, C50, C51, M06, M20
- Bright, clear, scratch‑free touchscreen display
Philips IntelliVue X2 Companion Monitor (M3002A)
- REF 865039 | S/N DE654U3739
- Date of Manufacture: 2017‑10‑19
- Software Revision: L.01.19
- Installed Options: C00, C01, C13, C15, C20
- Battery included (MED4607 Li‑Ion, holding charge; overnight charge recommended)
Philips M3001A MMS Module
- S/N DE6520GNW4
- Installed Options: A03 / C06
- Parameters: ECG/Resp, NIBP, Masimo SpO₂, Temperature
Philips M3015A Hemodynamic / CO₂ Module
- REF 862393 | S/N DE43547738
- Date of Manufacture: 2015‑12
- Parameters: IBP, Temperature, CO₂
Additional Components
- Philips Universal Docking Station (REF 8040A, Option A03)
- Philips Coiled Remote (REF 865244)
- Philips OEM X2‑to‑MX800 Monitor Interface Cable (REF M3081‑61626)
- Hospital‑grade power cord
Cosmetic Condition
- MX800: Excellent overall condition; no cracks, dents, or structural defects
- X2: Excellent condition with minor surface wear from normal use
- Displays: Both MX800 and X2 screens are bright, clear, and responsive
Functional Condition
System powers on normally and recognizes all connected modules
Core parameters tested: ECG, NIBP, SpO₂, Temperature
X2 operates correctly in both standalone and companion modes
MMS module fully functional with included accessories
Hemodynamic/CO₂ module functional for IBP and Temperature
CO₂ not fully tested (sampling lines not included)
IBP adapter cable included; IBP transducers not included
Connectivity
Rear panel includes LAN, Alarm, RS232, MIB/RS232, USB A–D, DVI‑style video output, Philips docking interface ports, and AC power input (100–240V AC, 50/60 Hz).
Included New OEM‑Compatible Accessories
5‑Lead ECG Cable – REF SG51245
Reusable Masimo‑Compatible SpO₂ Sensor – REF SP9325A
Adult NIBP Cuff – REF SE1711‑11
NIBP Hose – REF SH0910S
Reusable Temperature Probe – REF ST4305
IBP Adapter Cable – REF SB04111
Philips OEM charger‑to‑monitor interface cable
Hospital‑grade power cord
What Is Included
- Philips IntelliVue MX800 Monitor
- Philips IntelliVue X2 Companion Monitor
- Philips M3001A MMS Module
- Philips M3015A Hemodynamic/CO₂ Module
- Philips Universal Docking Station
- Philips Coiled Remote
- Philips OEM Interface Cable
- New OEM‑compatible accessory set
- Hospital‑grade power cord
What Is Not Included
- Rolling cart
- CO₂ sampling lines
- IBP transducers
- Additional cuffs (large, XL, pediatric, neonatal)
- Disposable sensors or consumables
- Pediatric/neonatal reusable sensors
- Additional modules or racks
- User manual
- Any items not specifically listed or shown
Important Configuration Note
This platform supports either:
- The X2 Companion Monitor configuration, or
- The MMS + Hemodynamic Co2 Module configuration
Only one primary monitoring configuration can be active at a time.
The included patient accessories may be used with:
- The X2 while docked, or
- The MMS module when connected to the MX800, the hemodynamic Co2 Module can work both configuration
Buyer Advisory Note
This MX800 system is in excellent cosmetic condition and has been tested for core monitoring functions. CO₂ and full IBP testing were not completed due to missing consumables. As with all clinical monitoring equipment, the buyer should have the system inspected, configured, calibrated, and approved by qualified biomedical personnel prior to clinical use.
Shipping Note
This multi‑component monitoring system will be professionally packaged for secure shipment from Medicka Medical, Minnesota.
Stock ID: 39382 (P.O. 2025) (WH104)