2015 Philips IntelliVue MX8...
2015 Philips IntelliVue MX800 Monitor w/ X2, M3012A Module, Dock & Leads ~ 39858
Item specifics
- Used
- Model
- MX800
MPN- 865240
Product details
Philips IntelliVue MX800 Patient Monitoring System w/ X2, M3012A Module & Dock
Short Description
The Philips IntelliVue MX800 bedside monitoring system is paired with an IntelliVue X2 portable companion monitor, an M3012A hemodynamic module, a universal docking station, Philips remote control, and a complete set of new OEM‑compatible patient accessories. The system was fully tested at our facility and demonstrated responsive touchscreen performance, waveform display, parameter recognition, profile switching, and seamless communication between the MX800 and X2.
Quick Condition Overview
Functional Status: Tested & Working
Cosmetic Condition: Very Good Overall
Display Status: Bright LCDs; responsive touchscreens
System Configuration: MX800 + X2 + M3012A + Dock + Remote
Completeness: Monitor system, docking station, remote, battery, power cord, and new OEM‑compatible accessories
System Components
Philips IntelliVue MX800 Main Monitor
- Model / REF: 865240
- Serial Number: DE50840091
- Manufacture Date:2015‑03
- Software Revision: K.21.42
- Installed Options: H10, A08, C06, C09
- Power Requirements: 100–240V AC, 50/60 Hz
- Country of Manufacture: Germany
- CE Marked: Yes
Philips IntelliVue X2 Companion Monitor
- Model: M3002A
- REF: 865039
- Serial Number: DE575N7545
- Manufacture Date: 2016‑09‑22
- Software Revision: L.01.21
- Installed Options: C00, C01, C13, C15, C20
- Supported Parameters: ECG/Resp, NIBP, Masimo SpO₂, Temperature
Installed X2 Battery
- Model:Philips M4607A
- REF: 989803148701
- Specs: 10.8V | 1080mAh | 11.7Wh | Li‑Ion
- Status: Holding charge; overnight conditioning recommended
Philips M3012A Hemodynamic Module
- Model / REF: 86211
- Serial Number: DE34713459
- Manufacture Date: 2007‑02
- Option: C05
- Capabilities: Dual IBP, dual temperature, cardiac output (CO)
- Note: Full IBP/CO testing not performed due to unavailable transducers
Philips Universal Docking Station
- REF: 8040A
- Option: A03
- Lot Number: 1921
- Includes integrated interface cable and pole/wall clamp assembly
Philips Remote Control
- REF: 865244
- Serial Number: DE12553997
- Manufacture Date: 2016‑05
- Coiled remote tested and functioning normally
Condition Summary
MX800 Monitor
- Very good cosmetic condition
- No cracks or structural defects
- Bright LCD; highly responsive touchscreen
- Light surface scratches present (cosmetic only)
X2 Companion Monitor
- Very good condition
- Bright display and responsive controls
- Clean connectors; intact handle
- Communicates properly with MX800
Docking Station & M3012A Module
- Very good overall condition
- Connectors and ports intact
- Dock includes rear clamp hardware
Cosmetics
- Normal clinical wear (minor scuffs, surface marks)
- Presents clean and professionally
Functionality / Testing Summary
System Testing
- MX800 powers on normally
- Touchscreen responsive
- Waveforms and parameters displayed correctly
- Profile switching functional
- Communication between MX800 and X2 confirmed
Waveform / Parameter Activity Observed
- ECG waveform
- Pleth waveform
- NIBP activity
- SpO₂ recognition
- Alarm activity
- Adult / Pediatric / Neonatal profiles
Display Modes Observed
Dynamic Waves, 8 Waves, 6 Waves, 4 Waves, Multiple Lead, Overlap 3 Waves, Overlap 2 Waves, 2 Large Waves, Horizon, Big Numbers, Visitor Clock, Monitor at Desk, Adult/Pediatric/Baby Profiles.
Rear Connectivity Ports on MX800
USB, RS232, alarm port, LAN/Ethernet, video output, expansion/module bays
Included New / OEM‑Compatible Accessories
5‑Lead ECG Cable – REF SG51245
Reusable Masimo‑Compatible SpO₂ Sensor – REF SP9325A
Adult NIBP Cuff – REF SE1711‑11
NIBP Hose – REF SH0910S
Reusable Temperature Probe – REF ST4305
IBP Adapter Cable – REF SB04111
Hospital‑grade power cord
Accessories are OEM‑compatible, manufactured by Sino‑K (China).
What Is Included
- Philips IntelliVue MX800 monitor
- Philips IntelliVue X2 companion monitor-Module
- Philips M3012A hemodynamic module
- Philips universal docking station
- Philips remote control
- Installed X2 battery
- New OEM‑compatible accessories listed above
- Hospital‑grade power cord
- Items shown in images
What Is Not Included
- Rolling cart / stand
- IBP transducers
- Additional cuffs (large adult, pediatric, neonatal)
- Disposable sensors or consumables
- Additional reusable sensors
- Additional parameter modules
- Additional module racks
- User manual / documentation
- PM or service records
- Any accessories not explicitly listed
Buyer Advisory Note
No preventive maintenance records are available. System was tested for general operational functionality, including touchscreen response, waveform display, parameter recognition, accessory detection, and communication between MX800 and X2. Buyer is responsible for verifying configuration, compatibility, and clinical requirements prior to deployment.
Stock ID: 39858 (P.O. 2025) (WH104 SCC13)