Philips IntelliVue MX800 Mo...
Philips IntelliVue MX800 Monitor w/ X2 M3001A+M3015A CO2 Module Leads Dock~39386
Item specifics
- Used
- Model
- MX800
MPN- 865240
Product details
Philips IntelliVue MX800 Patient Monitoring Platform w/ X2, MMS, Hemodynamic/CO₂ Module & Dock
Country of Manufacture: Germany
CE Marked: Yes
Short Description
Philips IntelliVue MX800 modular patient monitoring platform with X2 companion monitor, M3001A MMS module, M3015A Hemodynamic / CO₂ module, universal docking station, OEM Philips interface cable, hospital‑grade power cord, and a complete set of new OEM‑compatible patient accessories.
The system powers on, initializes, displays waveforms, responds to touchscreen commands, communicates with the X2, and supports adult, pediatric, neonatal, and comfort profiles with multiple configurable screen layouts and monitoring modes.
System Components
Philips IntelliVue MX800 Main Monitor
- REF: 865240
- Serial Number: DE50840081
- Date of Manufacture: 2015‑03
- Software Revision: K.21.42
- Installed Options: H10, A08, C06, C09
- Power Requirements: 100–240V AC, 50/60 Hz
Philips IntelliVue X2 Companion Monitor
- Model: M3002A
- REF: 865039
- Serial Number: DE654U3392
- Date of Manufacture: 2017‑10‑17
- Software Revision: M.04.05
- Installed Options: C00, C01, C13, C15, C20
- Battery Installed: Philips / MED4607 Li‑Ion
- Battery Status: Holding charge; overnight conditioning recommended
Philips M3001A MMS Module
- REF: 862442
- Serial Number: DE6520H7A0
- Date of Manufacture: 2018‑01‑08
- Installed Options: A03, C06
- Supported Parameters: ECG/Resp, NIBP, Masimo SpO₂, Temperature
Philips M3015A Hemodynamic / CO₂ Module
- REF: 862393
- Serial Number: DE43550787
- Date of Manufacture: 2012‑01
- Installed Option: C06
- Supported Parameters:IBP, Temperature, Microstream CO₂
Philips Universal Docking Station
- REF: 8040A
- Option: A03
- Features: Integrated interface connection with rear pole clamp assembly
Additional Included Components
- Philips OEM Charger‑to‑Monitor Interface Cable — REF M3081‑61602
- Hospital‑grade power cord
Quick Condition Overview
Functional Status: Tested & Working Cosmetic Condition: Excellent to Very Good Overall Display Quality: Bright LCD displays with responsive controls Parameters Available: ECG/Resp, NIBP, Masimo SpO₂, Temperature, IBP, CO₂ Profiles Available: Adult, Pediatric, Neonatal/Baby, Comfort Testing Limitation: CO₂ not fully tested due to unavailable sampling lines
Condition Summary
MX800 Main Monitor
- Excellent overall cosmetic condition
- No dents, cracks, or structural damage
- Rear cable/cover compartment intact
- Bright polychrome LCD display
- Highly responsive touchscreen
- One small scratch noted on display surface (cosmetic only)
- Rear ports and interfaces intact
Rear Connectivity
- USB ports (A–D)
- LAN port
- Alarm interface
- RS232 interface
- DVI/video‑style output
- Philips docking/module interfaces
- AC power input
Software / Menu Functions
System provides access to: Adult, Pediatric, Neonatal/Baby, Comfort profiles; Dynamic Waves; Multiple lead layouts; Big Numbers; Horizon; Tele overview; Patient overview; Demographics; Cardiac Output menus; Hemodynamic calculations; Pressure calculations; Venous pressure; Converter/calculator utilities; Multiple customizable screen layouts and waveform modes. No printer installed; compatible Philips printer modules may be added.
X2 Companion Monitor
- Excellent cosmetic condition
- Bright display; responsive soft keys
- Handle intact
- Clean connectors and ports
- Battery installed and holding charge
- No cracks or structural defects
M3001A MMS Module
- Excellent cosmetic condition
- Connectors and ports intact
- Recognized properly by MX800
- ECG/Resp, NIBP, Masimo SpO₂, and Temperature tested successfully
M3015A Hemodynamic / CO₂ Module
- Excellent cosmetic condition
- Connectors and release latch intact
- IBP and Temperature menus recognized
- CO₂ menu accessible
- CO₂ not fully tested due to unavailable sampling lines
Universal Docking Station
- Excellent overall condition
- Pole clamp installed
- Integrated connection interface intact
- No cracks or structural damage
Functionality & Testing Summary
- MX800 powers on and initializes successfully
- Touchscreen responsive
- X2 communication verified
- MMS module recognized
- Hemodynamic/CO₂ module recognized
- ECG waveforms displayed
- NIBP tested with sample readings
- Masimo‑compatible SpO₂ tested
- Temperature parameter functioning
- IBP menu accessible
- CO₂ menu accessible
- Multiple monitoring profiles accessible
- Multiple screen layouts and waveform modes accessible
Important Configuration Note
This platform supports either:
- The X2 Companion Monitor configuration, or
- The MMS + Hemodynamic Module configuration
Only one primary monitoring configuration can be active at a time.
The included patient accessories may be used with:
- The X2 while docked, or
- The MMS module when connected to the MX800
Included New / OEM‑Compatible Accessories
(Manufactured by Sino‑K, China)
5‑Lead ECG Cable — REF SG51245
Reusable Masimo‑Compatible SpO₂ Sensor — REF SP9325B
Adult NIBP Cuff — REF SE1711‑11
NIBP Hose — REF SH0910S
Reusable Temperature Probe — REF ST4305
IBP Adapter Cable — REF SB04111
Philips OEM Interface Cable — REF M3081‑61602
Hospital‑grade power cord
What Is Included
- Philips IntelliVue MX800 Monitor
- Philips IntelliVue X2 Companion Monitor
- Installed Li‑Ion X2 Battery
- Philips M3001A MMS Module
- Philips M3015A Hemodynamic / CO₂ Module
- Philips Universal Docking Station with Pole Clamp
- Philips OEM Interface Cable
- New OEM‑Compatible Patient Accessory Set
- Hospital‑Grade Power Cord
- Items shown in images
What Is Not Included
- Rolling cart / stand
- CO₂ sampling lines
- IBP transducers
- Additional cuffs (large adult, XL, pediatric, neonatal)
- Disposable sensors or consumables
- Pediatric/neonatal reusable sensors
- Additional parameter modules or racks
- Printer / recorder module
- User manual
- PM/service records
- Any items not specifically listed or shown
Buyer Advisory Note
No PM/service records are available. System has been tested for power‑on functionality, touchscreen response, module recognition, waveform display, and core parameter operation. CO₂ functionality was not fully verified due to unavailable sampling accessories. Buyer is responsible for confirming compatibility, calibration, and clinical requirements prior to patient use. Review all images carefully for cosmetic and configuration details.
Stock ID: 39386 (P.O. 2025) (WH104 SCC14)