For orders, please call: 952-232-5970

$0Checkout 0 Item(s)

MENU

    

2017 Covidien Nellcor SpO2 ...

2017 Covidien Nellcor SpO2 Patient Monitor 10005941 w/ Sensor DOC-10 Cable~39703

Item specifics

Condition
Used
Seller Notes
“Covidien Nellcor Bedside SpO₂ Patient Monitoring System — Pre‑owned unit in excellent cosmetic and functional condition. Powers on, passes self‑test, and provides accurate SpO₂ and pulse rate readings with stable waveform."
Model
10005941
MPN
10005941

More details


$455.20

39703

1 item in stock

Warning: Last item in stock!

Add to cart

Place an offer

Product details

Manufacturer

Covidien (Nellcor)

Item:

2017 Covidien Nellcor SpO2 Patient Monitor REF 10005941 w/ Sensor DOC-10 Cable

Model/Cat #        

10005941 

Serial No.        

MBB1700002

Made In:             

Korea

Date of Manufacture:  

2017-01-18


 Power:                    100–240V ~ 50/60Hz, 45VA 

Short Description:

Covidien Nellcor bedside SpO₂ patient monitoring system in excellent cosmetic and functional condition. Unit powers on, passes self-test, and accurately measures SpO₂ and pulse rate. Includes DOC-10 adapter cable and reusable adult finger sensor.

Software Version: 1.20.02 
Ingress Protection: IPX2

 

 

 

Condition:

Overall Cosmetic Condition: Device is in great pre-owned condition with no dents or structural damage. Minor surface scratches and scuffs may be present consistent with normal handling.

Display Condition: LCD is bright, clear, and free of scratches or visible defects. All on-screen elements render properly.

Housing & Structure: Outer housing is solid with intact handle. No cracks noted on the main unit. Edges and panels remain well aligned.

Ports & Connectivity: Right lateral side USB port is present and intact. Rear communication/connection port is clean and structurally sound.

Adapter Cable Condition: DOC-10 SpO₂ adapter cable shows a minor crack near the connector housing. Connection remains secure and functional; however, this is noted for transparency and long-term consideration.

 

Functionality Summary:

Power & Startup: Device powers on without delay, completes self-test, and reaches monitoring interface successfully.

Monitoring Performance: Tested with included adapter cable and sensor. Device accurately measured SpO₂ and pulse rate on operator with stable waveform and readings.

Controls & Navigation: Soft keys, rotary knob, and menu navigation are fully responsive. Patient mode, options menu, and system settings are accessible and functional.

Battery Status: Battery is installed and holds charge. Battery health is unknown due to storage conditions; recommend full overnight charging prior to clinical use.

What Is Included:

 

  • Hospital-grade power cord
  • Nellcor DOC-10 SpO₂ adapter cable
  • Reusable adult finger SpO₂ sensor (SINO-K Medical)

 

What Is NOT Included:
  • User manual
  • Original packaging
  • Pediatric or neonatal sensors
  • Disposable or consumable accessories
  • Rolling stand or mounting accessories
Battery Advisory:
Device has been tested for basic operational functionality only. Minor crack on adapter connector housing does not affect immediate use but may impact long-term durability. No biomedical certification or calibration report available.
 
Shipping Note:
Unit will be securely packaged and shipped with included accessories. Ready for immediate setup and testing upon arrival.
 
*Items shown in photos are the items that will ship.  If it is not shown in the photos, it is not included*
 
Stock ID : 39703 {P.O 3035} (OFH C3)

 

Comments:

Kindly enlarge the images and see them with zooming.

Concern or query: Ask a Question

Condition: USED, please refer to images for cosmetic condition.

  1. 1.    Overall Condition: As seen in images : Very Good
  2. 2.    Physical Condition: Please review images before bidding : Very Good
  3. 3.    Working Condition: Has been tested at our end & is in good functinality....Will receive item as pictured…………(Offered AS IS)
  4. 4.    As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
  5. 5.    Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)