Philips MP30 Intellivue Pat...
Philips MP30 Intellivue Patient Monitor W/ M3001A+ M3012A Module & Leads ~ 39181
Item specifics
- Used
- Model
- MP30
MPN- 862135
Product details
Manufacturer | Philips Healthcare |
Item: | Philips MP30 Intellivue Patient Monitor W/ M3001A+ M3012A Module & Leads |
Model/Cat # | MP30 / M8002A / 862135 |
Serial No. | DE72851703 |
Made In: | Germany |
Date of Manufacture: | 2008-05 |
Voltage: 100-240V 50-60Hz 1.8-1.0A
Short description:
This is a pre-owned Philips Intellivue MP30 (M8002A) Patient Monitor W/ MMS + Hemodynamic Modules & NEW Leads. Tested and fully functional with ECG, SpO₂ (Nellcor Oximax),NBP, CO2, 2x Press & 2x Temp parameters. Display is bright and responsive with minor surface scratches; overall cosmetic wear is minimal. Stand, user manual are not included. CE# 0366.
Specifications & Condition:
Software Version: M.03.03-3
Battery: Non-battery variant
Parameters: ECG, SpO2 (Nellcor Oximax), NBP, 2X IBP, 2X TEMP & CO2
Options: H40, A04, C01, C02, C15, C20
Printer: Not Installed
LCD: Responsive & bright | A couple of scratches noted
Handle: Intact
Trim Knob: Working
Softpads: Working
Dents or cracks: None noted
Scratches or scuffs: Minor cosmetic wear present
Logo Emblem: Intact
Connectivity & ports: LAN port available
Philips M3001A MMS Module:
- Ref: 862442
- SN# DE9070AVLT
- DOM: 2012-03
- Options: A04
- Module has been tested and is functioning properly
Philips M3012A Hemodynamic Module:
- Ref: 862111
- SN# DE83725589
- DOM: 2008-11
- Options: C05
- Module has been tested and is functioning properly
Included:
- 2008 Philips Intellivue MP30 (M8002A) Patient Monitor
- Philips M3001A MMS Module
- Philips M3012A Hemodynamic Module
- SpO2 Sensor Ref SP9325E (New)
- ECG Cable W/ Leads Ref SG5124S (New)
- NBP Hose Ref SH0910S (New)
- NBP Cuff Adult Ref SC2711-11 (New)
- IBP Cable Ref SB0411
- Power Cord
- Stand
- User Manual
- CO₂ Cable/Transducers
*Items shown in photos are the items that will ship. If it is not shown in the photos, it is not included*
Stock ID : 39181 (P.O 4014) (WH104 SCC6)
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition: USED, please refer to images for cosmetic condition.
- 1. Overall Condition: As seen in images - Very Good
- 2. Physical Condition: Please review images before bidding - Very Good
- 3. Working Condition: Has been tested at our end & is in good functionality as shown in the images.....Will receive item as pictured…………(Ofered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)