For orders, please call: 952-232-5970

$0Checkout 0 Item(s)

MENU

    

2014 Philips IntelliVue MX4...

2014 Philips IntelliVue MX450 Monitor w/ M3001A+M3012A Modules & New Leads~39628

Item specifics

Condition
Used
Seller Notes
“Pre‑owned Philips IntelliVue MX450 bedside patient monitor equipped with M3001A Multi‑Measurement Module and M3012A Hemodynamic Module, supporting ECG, respiration, NIBP, Masimo SpO₂, invasive pressure."
Model
MX450
MPN
866062

More details


$1,099.20

39628

1 item in stock

Warning: Last item in stock!

Add to cart

Place an offer

Product details

Manufacturer

Philips Medizin Systeme Böblingen GmbH

Item:

Philips IntelliVue MX450 Patient Monitor w/ M3001A MMS & M3012A Hemodynamic Module & Leads

Model/Cat #        

MX450 | Ref 866062

Serial No.        

DE35107079

Made In:             

Germany

Date of Manufacture:  

May 2014

Voltage:                   100–240V AC    50 / 60 Hz

Short description:

Philips IntelliVue MX450 bedside patient monitor equipped with M3001A Multi-Measurement Module and M3012A Hemodynamic Module. The system supports comprehensive patient monitoring including ECG, respiration, NIBP, Masimo SpO₂, invasive pressure, and temperature measurements. The monitor powers on, boots normally, and the touchscreen interface responds properly. The system includes new compatible patient monitoring accessories and remains in very good cosmetic and working condition.

Multi-Measurement Module (MMS)

 

  • Model: M3001A    
  • Option: A03C06    
  • Serial Number: DE907T3407    
  • Date of Manufacture: September 2009
  • Reference Number: 862442

 

Parameters Installed:

ECG, RESP, NIBP, TEMP, IBP      SpO₂ Type: Masimo

Hemodynamic Module

 

  • Model: M3012A     
  • Serial Number: DE34710102
  • Date of Manufacture: July 2006     
  • Option: C05
  • Parameters:     PRESS ×2    TEMP ×2     CO Enabled

 

Connectivity / Hardware: LAN    DVI   USB
Printer: Not Installed
BATTERY : NOT INSTALLED

 

System Software / Options

System Model: 866062   
Software Revision: M04.05-19

Installed Options:
H10, A04, C01, C13, C15, C17, C18, C19, C20, C21, C44, C45, C50, C51, C54, C06

 

Condition Summary:

Display Condition
The LCD display is bright and clear with good contrast. The touchscreen interface responds properly and the screen surface appears clean with no significant scratches observed.

Exterior Housing
The monitor housing is clean with minor cosmetic wear consistent with normal hospital use. No cracks or structural damage were observed.

Modules & Connectors
Both installed modules are properly seated and recognized by the system. Latches, module rails, and connectors are intact and appear in good condition.

Functionality / Testing Summary:

Power & Boot
The unit powers on and completes the boot sequence normally without system errors.

Navigation & Operation
Touchscreen navigation works properly. System menus, monitoring settings, and patient profiles are accessible.

Monitoring Performance
Physiological waveforms are visible and stable. NIBP measurement was verified. SpO₂, ECG, and temperature parameters were checked with compatible accessories and respond normally.

The hemodynamic module supports invasive pressure monitoring; however, IBP functionality was not fully tested during evaluation.

Profiles & Screen Layout Options

PACU Adult, SpO₂ + NIBP, Comfort, Pediatrics, Neonate profiles are available.
Display layouts include multi-wave configurations (4-wave + NIBP, 3-wave + NIBP), dynamic waveform display, SpO₂ + NIBP view, telemetry screen, split screen mode, vital signs view, horizontal layout, overlapping waveforms, large numerics, multi-lead ECG view, and bedside care display.

Included Accessories:

 

  • Philips IntelliVue MX450 Patient Monitor
  • M3001A Multi-Measurement Module
  • M3012A Hemodynamic Module

 

New Compatible Accessories (Sino-K):

 

  • NIBP Cuff SC2711-11 (35–27 cm)
  • NIBP Hose SHT09105
  • ECG Cable SG5124S
  • SpO₂ Sensor SP9325B
  • Temperature Probe ST1305
  • IBP Adapter Cable SB0411
  • AC Power Cord

 

What Is Not Included:

 

  • Original Philips accessories
  • User manual
  • Patient accessories not listed above
  • Rolling stand or mounting hardware

 

Buyer Advisory Note:
This device is intended for professional medical use. Calibration, configuration, and preventive maintenance may be required prior to clinical deployment depending on facility protocols.

Shipping Note:
The monitor and modules will be securely packaged using protective materials to ensure safe transit.

*Items shown in photos are the items that will ship.  If it is not shown in the photos, it is not included*

Stock ID : 39628 {P.O 3034} (R3 C11)

Comments:

Kindly enlarge the images and see them with zooming.

Concern or query: Ask a Question

Condition: USED, please refer to images for cosmetic condition.

  1. 1.    Overall Condition: As seen in images - Very Good
  2. 2.    Physical Condition: Please review images before bidding - Very Good
  3. 3.    Working Condition: The unit powers on and completes the boot sequence normally without system errors........Will receive item as pictured…………(Offered AS IS)
  4. 4.    As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
  5. 5.    Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)