For orders, please call: 952-232-5970

$0Checkout 0 Item(s)

MENU

    

2015 Covidien BIS Aspect Mo...

2015 Covidien BIS Aspect Monitor (185-0151) W/ BISx4 Module + IF Cables ~ 39093

Item specifics

Condition
Used
Seller Notes
“Pre-owned Covidien / Aspect BIS Monitoring System with BISx4 (BISLOC) 4-channel module (Ref. 185-1016-AMS), patient interface cable (PIC-4GR106686), and device interface cable (P/N 10115253). Unit powers on."
Model
185-0151
MPN
185-0151

More details


$598.40

39093

1 item in stock

Warning: Last item in stock!

Add to cart

Place an offer

Product details

Manufacturer

Covidien LLC

Item:

2015 Covidien BIS Aspect Monitor W/ BISx4 Module, Patient Interface Cable, Device Interface Cable | Ref 185-0151

Model/Cat #        

185-0151

Serial No.        

VT38299

Made In:             

USA

Date of Manufacture:  

2015

Voltage:                  100–240V | 50–60Hz | 0.7A            


Short description:

Covidien / Aspect BIS Aspect Monitoring System paired with a BISx4 (BISLOC) 4-channel module, supplied with patient interface cable and device interface cable. The system powers on, runs BISx internal diagnostics, passes self-test, and displays the expected “Connect sensor or cable” message when no disposable sensor is attached. LCD is bright, calibrated, and responsive. Suitable for desk use, pole mounting, or rolling stand integration (stand not included). CE Mark: 0123

Module Information:

 

 

 

 

  • Module Model / Ref #: 185-1016– AMS    
  • Module Type: BISx4 / BISLOC 4-Channel Module
  • Module Serial Number: B449236
  • Module DOM: 2021
  • CE Mark: 0123

Software Information:

Monitor Software Versions

  • Platform: 2.03
  • Application: 3.22
  • Splash Screen: 2.01
  • Boot Script: 2.00
  • Demo Data 1: 2.00
  • Demo Data 2: 2.00
  • Monitor: 3.22

System Revisions

  • Host Protocol Revision: 1.12
  • BISx Protocol Revision: 1.05
  • Hardware Revision: 4.00

Cables & Interfaces

  • Patient Interface Cable | Ref PIC-4GR106686

    • Length: approx. 4 ft

    • No cuts, tears, or exposed wiring

    • Sensor connector in good condition

  • Device Interface Cable | P/N 10115253

    • Length: approx. 10 ft

    • No cuts or tears observed

    • Connector pins clean and intact

Condition Summary:

  • Overall Cosmetic Condition: Good
  • LCD is bright, but has some dirt spots
  • Minor scuffs and surface marks consistent with normal clinical use
  • Front panel buttons are intact
  • Housing has a crack at front; see images
  • Rear mounting area / clamp interface present and intact
  • Labels, serials, and regulatory markings clearly legible

Functionality Summary:

  • Unit powers on and initializes correctly
  • Internal self-test completed and passed
  • BISx module recognized and tested successfully
  • Menu navigation smooth and responsive
  • Touchscreen fully responsive
  • Correct BISx Sensor connection prompt displayed
  • Unit operates normally on AC power
  • No error message displayed
  • Patient monitoring not fully tested due to absence of disposable BIS sensors
What's Included:
  • (1) Covidien / Aspect BIS Aspect Monitor (Ref. 185-0151)
  • (1) BISx4 / BISLOC 4-Channel Module (Ref. 185-1016-AMS)
  • (1) Patient Interface Cable (PIC-4GR106686)
  • (1) Device Interface Cable (P/N 10115253)
  • (1) Power cord

What's Not Included:

  • No BIS disposable sensors
  • No consumables
  • No user manual
  • No rolling stand, pole stand, or desk stand (unit is compatible but stand is not included)
  • No additional accessories not shown
Buyer Advisory Note:
Disposable BIS sensors are required for clinical use and are not included
Buyer is responsible for confirming compatibility with their intended BIS sensor setup
Testing performed includes power-on, self-test, module recognition, and menu operation only

Shipping Note:
Unit will be professionally packaged
Shipped via ground service by default
Partial disassembly may be performed to ensure safe transit


*Items shown in photos are the items that will ship.  If it is not shown in the photos, it is not included*

 

Stock ID : 39093 (P.O 2022) (R3 C15)

 

Comments:

Kindly enlarge the images and see them with zooming.

Concern or query: Ask a Question

Condition: USED, please refer to images for cosmetic condition.

  1. 1.    Overall Condition: As seen in images - Good
  2. 2.    Physical Condition: Please review images before bidding - Good
  3. 3.    Working Condition: Has been tested at our end & is in good functionality....Will receive item as pictured ……………(Offered AS IS)
  4. 4.    As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”