Philips/Agilent VARIDIA 24C...
Philips/Agilent VARIDIA 24C/26 Anesthesia Monitor W/ M1041A Rack+7 Modules~38868
Item specifics
- Used
- Model
- 24C
MPN- M1204A
Product details
Manufacturer | HP / Philips / Agilent |
Item: | Philips / Agilent VARIDIA 24C/26 Anesthesia Monitor System w/ M1041A Rack + 7 Modules & Leads |
Model/Cat # | 24C | M1204A | M1205A |
Serial No. | 4006A7294 |
Made In: | Germany |
Date of Manufacture: | U/K |
Voltage: 100–240V | 50–60Hz | 150 VA
Short description:
Pre-owned HP/Philips/Agilent VARIDIA 24C/26 Anesthesia Monitoring System with M1205A color display, M1041A 8-slot module rack, and 7 installed modules (ECG, NIBP, SpO₂, Temp, 2× Pressure, CO₂). System powers on, boots properly, and verifies ECG, SpO₂, NIBP, and Temp functions; pressure modules recognized but not fully tested, CO₂ module included but not supported by current software. Includes pole clamp, power cord, and a mix of new/used accessories.
Monitor Information & Condition:
- Display Type: Polychromatic Color Display (Non-Touch)
- Installed software / options reported:
- H35, B.0, SDN, M1235A DTM, M1022A BAM, M1012B CO
- Color display operational
- Front soft keys responsive
- Housing structurally intact without cracks
- Screen has noticeable cosmetic scratching
- General surface wear consistent with prior professional use
- Handle intact and secure
System supports and operates:
- Adult / Pediatric / Neonatal profiles
- Procedure modes and trends
- Adjustable screen formats
- Date / time setup and configuration
Note: CO₂ software is not installed; therefore the included CO₂ module is not recognized by the system.
- Manufacturer: Agilent
- Model: M1041A – 8B Module Rack / Server
- SN# DE805A1647
- Date of Manufacture: 06/2002
- CE 0366
- Made in Germany
- Philips Part No. 5061-8363 Pole Clamp (Capacity 6.5 kg / 14 lbs)
- 8-slot capacity
- Side handles intact
- Good structural integrity
1️⃣ NIBP Module Model: M1008B Serial: DE911G2215D DOM: 03/2003
2️⃣ ECG Module Model: M1001B Serial: 3218G10131
3️⃣ SpO₂ / Pleth Module Model: M1020A Serial: 3504A42138 Option: ABA
4️⃣ Pressure Module Model: M1006A Serial: 3006A823373 Option: ABA
Note: Zero soft pad cover degenerated
5️⃣ Pressure Module Manufacturer: Agilent Model: M1006B Serial: DE805B3025 DOM: 06/2001
6️⃣ Temperature Module Model: M1029A Serial: 3731A31039 Option: ABA DOM: 08/1997
7️⃣ CO₂ Module Model: M1016A Serial: 3022A00229 Option: ABA
Module Functionality Notes:
- ✔ ECG – tested and working
- ✔ NIBP – tested and working
- ✔ SpO₂ – tested and working
- ✔ Temperature – tested and working
- ✔ Pressure modules – recognized by the system (not fully pressure-tested)
- ❌ CO₂ module not recognized due to absence of installed CO₂ software; functionality unknown
Cosmetic Condition:
- Monitor casing structurally intact without cracks or dents
- Screen has notable surface scratching
- Modules in overall good cosmetic and functional condition
- General professional-use cosmetic wear present
- Hospital deinstalled working equipment
Functionality Summary:
- The system powers on, boots properly, recognizes modules, and performs patient monitoring functions.
- Verified working clinical parameters: ECG, SpO₂, NIBP, Temperature
- Pressure modules are acknowledged but not fully clinically verified.
- CO₂ module is included but not supported by current system software; capability unverified.
(Mix of new and used; most are new unless stated)
- Adult NIBP Adapter Hose – Single Tube REF: SH0910S – New
- Reusable Temperature Probe – Skin Type REF: ST1305 – New
- ECG Cable with 5-Lead Wire Set REF: ST5124S – New
- IBP Adapter Cable – MEDEX / Abbott Transducer Type REF: SB0411 – New
- Reusable Adult NIBP Cuff Size: 27–35 cm REF: SC2711-11 – New
- Reusable SpO₂ Sensor – Nellcor Type REF: SP91198 – New
- Philips OEM SpO₂ Extension Cable Model: M1900B – Used
- Monitor-to-Module Rack Interface Cable – OEM Used
- Hospital-Grade Power Cord
Accessory Manufacturer Note:
Most new accessories are manufactured by SINO-K Medical, CE 0123, latex-free.
Not Included:
Buyer Notes:
Buyer is responsible for verifying clinical compatibility, calibration needs, and compliance prior to patient use. CO₂ capability cannot be guaranteed due to software limitation.
*Items shown in photos are the items that will ship. If it is not shown in the photos, it is not included*
Stock ID : 38868 {P.O 4015} (WH104)
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition: USED, please refer to images for cosmetic condition.
- 1. Overall Condition: As seen in images - Very Good
- 2. Physical Condition: Please review images before bidding - Good
- 3. Working Condition: Has been tested at our end & functionality has been shown in the images......Will receive item as pictured…………(Offered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)