Philips IntelliVue MP50 Neo...
Philips IntelliVue MP50 Neo/Peds Patient Monitor W/ M3001A Module & Leads ~38874
Item specifics
- Used
- Model
- MP50
MPN- M8004A
Product details
Manufacturer | Philips Healthcare |
Item: | Philips IntelliVue MP50 Neonatal / Pediatric Patient Monitor W/ M3001A Module & Leads |
Model/Cat # | MP50 / M8004A |
Serial No. | DE82065971 |
Made In: | Germany |
Date of Manufacture: | April 2009 |
Voltage: 100–240V | 50/60Hz | 1.8–1.0A
Short description:
Fully functional Philips IntelliVue MP50 Neonatal / Pediatric Monitoring System with masimo and Nellcor SpO₂ capability, multiparameter module installed, dual side module bay configuration, integrated recorder, NICU-ready clinical profiles, bright touchscreen display, and multiple new CE-marked reusable accessories included.
Device Information:
Installed Options: H20, A04, C01, C02, C04, C09, C15, C20, C60
Software Version: L.01.17
Profiles Available: NICU | Neonatal | Pediatric | Adult | NICU Visitor | Custom Clinical Modes
Display: Touchscreen Color LCD (Highly responsive)
Battery: Non-battery variant – battery slots present but this variant does not support battery installation
Multiparameter Module (Included – Rear Slot)
Model: Philips M3001A Option: A03C06 Serial No.: DE717K4393
DOM: 07/2007 CE: 0366
Parameters Enabled via Module:
• ECG / Respiration • SpO₂ (Masimo SET) • NIBP • Temperature • IBP / Pressure
Left Side Integrated Module Housing:
Currently Installed Modules:
• Philips M1106B – Pressure Module
SN: DE805F0444 | DOM: March 2003
• Philips M1020B SpO₂ Module – Nellcor Type
Ref: M1020-50011 | SN: DE62005938 | DOM: Aug 2010
Condition (Modules):
No dents or cracks, front soft keys intact, connectors clean, lower release latch clips intact, rear connectors good.
Right-Side Recorder / Printer Module:
Model: HP M1116B Recorder Module
SN: 330-882-0407
Module intact, buttons responsive. Printer paper not installed → not fully tested.
Condition Summary:
• Touchscreen bright, clear, and highly responsive
• Minor cosmetic scratch on the inferior front bezel – does not affect visibility or function
• Rear casing, chassis, handle intact with no cracks or structural damage
• Front keypad & trim knob responsive
• Monitor boots correctly to IntelliVue Neonatal Platform
• Module housing secure and clean
• Normal cosmetic surface signs from prior professional use
Functionality / Testing Summary:
• Passed power-on and functional startup self-test
• Recognizes all installed modules
• Neonatal / Pediatric / Adult monitoring screens functional
• Supported Screen Views Include: Big Numbers | 3 Wave | 4 Wave | Trends | Horizon Trend | OxyCRG | Split Screen | NICU Visitor Mode
• Alarm configuration operational
• Recorder powers but untested due to missing paper
• Clinical tools available: ST Map, 12-Lead Capability, Calculations, Reporting, Data Trending, Interface Tools, Patient Demographics & Networking Features
Included Accessories:
(All new, Sino-K Medical, CE Marked, Latex-Free)
✔ Temperature Probe – Skin Type (Ref: ST1305)
✔ ECG Lead Set – 5 Lead Snap AHA (Ref: SG5124S)
✔ SpO₂ Direct Sensor – Masimo Type (Ref: SP9325B – Adult)
✔ SpO₂ Direct Sensor – Nellcor Type (Ref: SP9325A – Adult)
✔ IBP Adapter Cable – MEDEX / Abbott Type (Ref: SB0411)
✔ NIBP Adapter Hose – Adult Single Tube (Ref: SH0910S)
✔ Reusable Adult Cuff 27–35 cm (Ref: SC2711-11)
✔ Power Cord
What Is Not Included:
✖ Pediatric / Neonatal cuffs & SPO₂ sensors (adult only included – buyer may substitute as needed)
✖ Printer Paper
✖ CO₂ / EtCO₂ Module
✖ Hemodynamic Extension Modules
✖ Rolling Stand / Trolley
✖ Consumables / Disposables / ECG electrodes
✖ User Manual
Buyer Advisory Note:
Included SpO₂ sensors and NIBP cuffs are adult size and suitable for adult / pediatric use but not neonatal. System supports neonatal monitoring, but appropriate neonatal accessories should be sourced by the clinical user. Printer is present but untested due to missing paper.
Shipping Note:
Securely packaged with professional medical equipment packing. International buyers welcome.
*Items shown in photos are the items that will ship. If it is not shown in the photos, it is not included*
Stock ID : 38874 {P.O 4014} (R1 C6)
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition: USED, please refer to images for cosmetic condition.
- 1. Overall Condition: As seen in images - Very Good
- 2. Physical Condition: Please review images before bidding - Very Good
- 3. Working Condition: Has been tested at our end & functionality has been shown in the images......Will receive item as pictured…………(Offered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)
