HP/Agilent Viridia 24C Anesthesia Monitor W/ 8-Slot Rack, Modules & Leads ~38856
Item specifics
- Used
- Model
- 24C
MPN- M1204A
Product details
Manufacturer | Hewlett Packard / Agilent |
Item: | HP / Agilent Viridia 24C Anesthesia Monitor M1204A w/ 8-Slot Rack, Modules, Cables & Accessories |
Model/Cat # | 24C | M1204A | M1205A |
Serial No. | 3812A32094 |
Made In: | Germany |
Date of Manufacture: | U/K |
Voltage: 100–240 VAC | 50–60 Hz | 150 VA
Short description:
HP / Agilent Viridia 24C Anesthesia Monitor (M1204A / M1205A) with Agilent 8‑Slot Rack – Powers on, passes self‑test, bright display, and modules detected (NBP, ECG/RESP, Temp, SpO₂, IBP). Includes new accessories: ECG cable, temp probe, NIBP cuff/hose, IBP adapter, SpO₂ sensor + OEM extension cable, rack interface cable, and power cord. Good cosmetic condition with minor wear; sold As‑Is, no printer/EtCO₂/BIS modules or transducers.
Device Information:
- Options Installed: 021 041 ABA H01
- Preventive Maintenance: Last sticker indicates 02/2019
- Display: Polychrome color display – bright, clear, and responsive
- Housing Condition: Very good overall; no cracks or dents; normal scratches / scuffs only
Physical Features:
- Desk-top base stand with rear storage tray
- Dual side cable caddies
- All front soft keys intact and responsive
- Brand: Agilent
- Model: M1041A (8-bay rack)
- Serial Number: 3805G63926
- DOM: 10/2000
- Capacity: 8 parameters slots
- Condition: Good overall; cosmetic scuffs/scratches; latch mechanisms intact
- Module interface cable cover missing (cosmetic only)
- EEPROM: M1204-10423
System SW / HW Components Detected:
• System Board: M1204-60101
• FE-IF: M1204-60101
• CDSPC_FLAT: M1074-60100- Software Revision: E.00.06
- Language: English
Modules & Supported Parameters:
1. NBP Module – AGILENT M1008B S/N DE911E2843 – DOM 03/2002
2. ECG / RESP Module – HP M1002A S/N 293-780-9575 – Option ABA
3. Temperature Module – HP M1029A S/N 373-183-1109 – DOM 08/1997
4. SpO₂ / Pleth Module – HP M1020B S/N 3343G19951 – SpO₂/Pleth enabled
5. IBP / Pressure Module – AGILENT M1006B S/N DE805B3026 – DOM 06/2001
6. One Philips Dummy Module Installed
Note on Module Rack Slots:
Module rack appears responsive overall; however, the last two bays with the dummy module may be less responsive/not synchronizing ideally. They can be repurposed for other supported modules such as CO2, printer, BIS, additional invasive pressures, vent modules, etc.
Condition:
- Monitor body, rack, and modules in good physical and functional condition
- Screen bright and sharp
- Cosmetic condition: used – may show minor handling wear
- No cracks, structural damage, or missing buttons
- Dummy module present
- Two rear cosmetic cable cover pieces missing on rack
Functionality Summary:
- Monitor powers on and passes self-test
- Boots to main screen normally
- Displays patient monitoring screens correctly
- Operator menus function correctly
- NBP inflates and measures (verified)
- ECG shows waveform when leads applied
- Temperature and RESP parameters enable normally
- IBP not fully tested due to lack of transducer set (disposable not included)
- SpO₂ displayed “No Transducer / Equipment Malfunction” when sensor not attached – expected behavior without sensor
All below (except where noted) are new, CE 0123 certified, manufactured by Shenzhen Sino-K Medical Technology, China:
- ECG Cable with 5-Lead Patient Lead Wire Set
- REF ST5124S,snap lead wire connectors
- Reusable Skin Temperature Probe | REF ST1305
- Adult NIBP Single Tube Hose Adapter | REF SH0910S
- IBP Adapter Cable – Medex / Abbott Type | REF SB0411
- Reusable Adult NIBP Cuff | Size 35 × 27 cm | REF SC2711-11
- Reusable SpO₂ Sensor – Nellcor Type | REF SP9119B
- OEM Philips SpO₂ Extension Cable | REF M1900B [ Note: Cable sheath has an insulation tear near the sensor connector and has been taped (blue).]
- Monitor to Module Rack Interface Cable
- Hospital-grade power cord
Not Included:
- No printer module
- No EtCO₂ module
- No BIS
- No invasive transducers
- No disposables or consumables other than listed
- No OEM manual
Buyer Notes:
*Items shown in photos are the items that will ship. If it is not shown in the photos, it is not included*
Stock ID : 38856 {P.O 4015} (WH104)
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition: USED, please refer to images for cosmetic condition.
- 1. Overall Condition: As seen in images - Very Good
- 2. Physical Condition: Please review images before bidding - Very Good
- 3. Working Condition: Has been tested at our end & functionality has been shown in the images......Will receive item as pictured…………(Offered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)