Philips IntelliVue MP50 Mon...
Philips IntelliVue MP50 Monitor W/ MMS, IBP, Temp, Recorder Module & Leads~38385
Item specifics
- Used
- Model
- MP50
MPN- M8004A
Product details
Manufacturer | Philips Healthcare |
Item: | Philips IntelliVue MP50 Monitor W/ MMS, IBP, Temp, Recorder Module & Leads |
Model/Cat # | MP50 / M8004A |
Serial No. | DEA2060095 |
Made In: | Germany |
Date of Manufacture: | 10-2008 |
Voltage: 100-240V 50-60Hz 1.8-1.0A
Short description:
Philips IntelliVue MP50 touchscreen critical-care monitor configured with MMS module, temperature/pressure module, invasive pressure module, and recorder module installed. The monitor powers on normally, LCD is bright and scratch-free, touchscreen is responsive, and all installed modules are recognized by the system.
Software Version: F.01.43
Installed Options: H10, A06, C01, C02, C05, C15, C20
Battery Configuration: Two battery slots present; no batteries installed (Buyer is advised to install new batteries if battery operation is required)
Network: LAN port present Ports: Two auxiliary serial ports, one video output port
Patient Profiles: ICU Adult / Adult / Pediatric / Neonatal / NIBP-SpO₂ / Comfort Care
Display Modes & Screen Options:
Telemetry + 1 Wave, Telemetry Screen, 4-Wave (2 ECG + MVP Trend), 4-Wave (1 ECG), 4-Wave Split Trend, 3-Wave MVP Trend, 3-Wave, Basic Screen, 1-Wave Screen, 6-Wave (2 ECG + NBP Trend), Big Numerics, Horizon, Trend, Multi-Lead ECG, Patient Overview, Comfort Care
CONDITION:
- LCD: Bright, clear, and scratch-free
- Touchscreen: Fully responsive
- Front Bezel: Intact; no dense cracks
- Side Controls: Fully functional
- Rear Handle: Intact and secure
- Housing: Minor cosmetic wear consistent with prior clinical use
- Overall Condition: Very good cosmetic and functional condition
- Device boots and navigates menus correctly
- All installed modules are recognized by the system
- System-wide measurement capability includes: ECG / RESP SpO₂ (Nellcor) NIBP Temperature Invasive Pressure Recorder
- IBP not pressure-tested due to lack of disposable transducers
- Device has been tested for basic operation and appears to be working well
MODULE CONFIGURATION (INSTALLED):
MMS Module
- Model: M3001A Reference Number: 862442 Option: A01C06 Serial Number: DE9070527 Date of Manufacture: 04 / 2013
- Parameters: ECG/RESP, NIBP, SpO₂ (Nellcor), Pressure, Temperature
- Condition: Good; connectors intact; minor cosmetic wear only
Temperature / Pressure Module
- Model: M1029A Option: ABA Serial Number: 3805G64212 Date of Manufacture: 11 / 2002
- Condition: No dents or cracks; light cosmetic wear; recognized by system
IBP / Pressure Module
- Model: M1006B Serial Number: DE8057052 Date of Manufacture: 09 / 2009 CE: 0366
- Condition: Good cosmetic condition; no cracks; recognized by system
Recorder / Printer Module
- Model: M1116B Serial Number: 3809A74457 Date of Manufacture: 05 / 1999 Option: 2012114P1ABA
- Condition: Recognized by system; minor scratches and scuffs
- Note: Printer paper not included
MODULE & SLOT CAPACITY:
- Side module bay: Currently populated with recorder, pressure, and temperature modules
- Posterior bay: Supports MMS and hemodynamic extension modules
- Additional supported modules (not included): CO₂, BIS, ventilator, and other specialty extension modules (subject to software compatibility)
Included:
Equipment
- Philips IntelliVue MP50 Critical Care Monitor
- MMS Module
- Temperature / Pressure Module
- IBP / Pressure Module
- Recorder / Printer Module
- Power Cord
- ST1305 Reusable Temperature Probe
- SG5124S ECG Trunk Cable + 5-Lead Set (Adult)
- SP9325A Adult Direct-Connect SpO₂ Sensor (Nellcor type)
- SH0910S NIBP Hose
- SC2711-11 Adult Reusable NIBP Cuff
- SB0411 IBP Adapter Cable (Medex / Abbott style)
- CO₂ module
- BIS module
- Ventilator or other specialty modules
- Additional hemodynamic modules beyond those listed
- Printer paper
- Rolling stand or bedrail mounts
- User manual
- Pediatric or neonatal sensors or cuffs
- Device is pre-owned and not patient-ready
- Calibration, certification, and clinical validation are the responsibility of the buyer
- IBP not pressure-tested due to lack of disposable transducers
- Batteries not included; install new batteries if portable operation is required
- Please review all images carefully for cosmetic details and module configuration
*Items shown in photos are the items that will ship. If it is not shown in the photos, it is not included*
Stock ID : 38385 (P.O 5007) (WH104)
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition: USED, please refer to images for cosmetic condition.
- 1. Overall Condition: As seen in images - Very Good
- 2. Physical Condition: Please review images before bidding - Very Good
- 3. Working Condition: Has been tested at our end & is in good functionality as shown in the images.....Will receive item as pictured ……………(offered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)