Philips MP50 Intellivue Mon...
Philips MP50 Intellivue Monitor W/ MMS, Press, Temp, REC Module & Leads ~ 38791
Item specifics
- Used
- Model
- MP50
MPN- M8004A
Product details
Manufacturer | Philips Healthcare |
Item: | 2009 Philips MP50 Intellivue Monitor W/ MMS, Press, Temp, REC Module & NEW Leads |
Model/Cat # | MP50 / M8004A |
Serial No. | DE82072847 |
Made In: | Germany |
Date of Manufacture: | 2009–11 |
Voltage: 100-240V 50-60Hz 1.8-1.0A
Short description:
This is a fully functional Philips IntelliVue MP50 (M8004A) patient monitoring system with a complete set of critical-care measurement modules installed: ECG/Resp, NIBP, SpO₂ (OxiMax), Temperature, IBP×2, and Recorder. The system includes an MMS module, invasive pressure module, temperature module, and recorder module, all tested and recognized by the host monitor. Touchscreen display is bright, clean, and highly responsive. Suitable for Adult, Pediatric, and Neonatal monitoring environments.
Software Revision: G.01.79
Installed Options: H10, A06, C01, C02, C15, C20
Variant: Non-battery (AC-only) model
Display: Philips IntelliVue E-Color LCD Touchscreen
Module Capacity:
- 1 MMS bay w/ Multiple hemodynamic extension modules
- Side-slot capacity for 4 additional compatible modules (CO₂, BIS, Pressure, Recorder, Temperature, etc.)
1. MMS Module (Multi-Measurement Server)
- REF: M3001A
- Serial Number: DE512A19931
- Functions Installed: ECG / Respiration SpO₂ (Nellcor / OxiMax) NIBP Temperature IBP ×2
- Condition: Excellent; latch intact and functioning.
2. Invasive Pressure Module (IBP Module)
- Model: M1006B
- REF: 862777
- erial Number: DE40U85970
- Channels: Dual invasive pressure (P1/P2)
- Condition: Clean connector, rotates smoothly.
3. Temperature Module
- REF: M1029A
- Serial Number: DE409B6662
- Functions: Single temperature channel
- Condition: Excellent; port firm and clean.
4. Recorder Module
- REF: M1116B
- Serial Number: 4227A61541
- Date: 2008–06
- Function: Paper recording of ECG, waves, NBP, trends
- Condition: Door and latch intact.
- Very good overall cosmetic condition—no cracks or dents, only minor scuffs from normal use.
- E-Color LCD touchscreen is bright and responsive with no dead pixels.
- Trim knob works smoothly; all soft keys respond.
- Handle intact and secure.
- Modules seat firmly; side slots clean.
- Hemodynamic extension frame intact with available space for 4 additional compatible modules.
- Monitor powers on normally and passes full self-test.
- All installed modules recognized and active: ECG / Respiration, SpO₂ (Nellcor / OxiMax), NIBP (Auto/Manual), Temp, IBP,, P1 / P2, Recorder (paper not included)
- Profile Modes: Adult, Pediatric, Neonatal
- Screen / View Modes: Standard, Large Numerics, Invasive Line, Swan-Ganz / Hemodynamic, All-Lead ECG, Patient Overview, X2 Transport compatible view, Privacy mode
- Networking, trends, alarm management, and touchscreen configuration all working correctly.
- The device has been fully tested at our location and functions very well.
Included:
- Philips IntelliVue MP50 Monitor (M8004A)
- MMS Module – M3001A
- IBP Module – M1006B
- Temperature Module – M1029A
- Recorder Module – M1116B
- ST1305 Reusable Temperature Probe
- SG5124S ECG Trunk Cable + 5-Lead Set
- SP9325S Adult Direct-Connect SpO₂ Sensor (Nellcor type)
- SH0910S NIBP Hose
- SC2711-11 Adult Reusable NIBP Cuff
- SB0411 IBP Adapter Cable (Medex/Abbott style)
- Power Cord (Included)
- CO₂ module (not included)
- BIS module (not included)
- Additional hemodynamic or specialty modules beyond those listed
- Recorder paper
- Rolling stand or bedrail mounts
- User manual
- Battery (this is a non-battery variant)
*Items shown in photos are the items that will ship. If it is not shown in the photos, it is not included*
Stock ID : 38791 (P.O 4014) (R1 C7)
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition: USED, please refer to images for cosmetic condition.
- 1. Overall Condition: As seen in images - Very Good
- 2. Physical Condition: Please review images before bidding - Very Good
- 3. Working Condition: Has been tested at our end & is in good functionality as shown in the images.....Will receive item as pictured ……………(offered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”