Seller Notes
“GE Dash 4000 Patient Monitor (Ref 2035598-203), DOM 2007, USA-made. Unit powers on with bright, clear LCD and responds to ECG, SpO₂ (Masimo), NIBP, IBP ×2, and Temp/CO inputs during cable testing."
Model
Dash 4000
MPN
2035598-203

More details


$98.40

38305

1 item in stock

Warning: Last item in stock!

Add to cart

Place an offer

Product details

Manufacturer

GE Medical Systems

Item:

GE Dash 4000 Patient Monitor – Masimo SPO2 / TEMP / NIBP / IBP / ECG

Model/Cat #        

Dash 4000 / Ref 2035598-203

Serial No.        

SD007241901GA

Made In:             

USA

Date of Manufacture:  

2007-06

Voltage:                  100–240 V AC • 50/60 Hz • 75 W

                   

Short description:

GE Dash 3000/4000/5000 patient monitor (P/N 2035598-203), tested with multiple cables and parameters. Unit powers on, LCD is bright, parameters respond, and all installed hardware appears functional. However, the trim knob is unresponsive, preventing full navigation of the menu system. Because of the trim knob failure and unknown software configuration, the unit is being sold AS-IS / For Parts Use Only.

Installed Hardware Ports (per rear I/O panel):

 

  • ECG (3/5-lead)
  • SpO₂ – Masimo SET
  • NIBP – DINAMAP technology
  • IBP x2 (Invasive BP #1 and #2)
  • Temperature / CO
  • CO₂ (hardware cavity present; software activation unknown)

 

Battery Bays:

 

  • Two battery slots (empty)
  • Both battery doors intact

 

Printer Bay:

 

  • Left-side recorder/printer slot empty (printer NOT installed)
  • Right-side compartment closed and intact

 

Condition:
  • Monitor powers on; screen is bright, clear, and scratch-free
  • Navigation impossible due to non-working trim knob
  • Housing in overall good shape: no dents or cracks, only normal scuffs/scratches
  • Printer bay empty
  • Battery slots empty
  • Rear ports clean and pins intact
  • Side plastics intact with expected wear
  • No missing trim pieces
  • Hardware detected for ECG, SpO₂ (Masimo), NIBP, two IBP channels, Temp/CO, and CO₂
  • CO₂ software activation not confirmed
  • System software level unidentified
  • Cosmetic Grade: Good Used Condition
  • Functional Grade: For Parts / Repair Only
Functionality Summary:
  • Unit powers on normally
  • Display fully functional
  • Tested with leads and cables — ECG, SpO₂, IBP, NIBP all responded
  • Trim knob does NOT respond, menus cannot be navigated → major limitation
  • Printer not installed
  • CO₂ status unknown (hardware port present; software may or may not be enabled)
  • Batteries not included; unable to test battery operation
  • Due to trim knob failure and unknown software, unit is AS-IS / No Warranty

Included:
  • GE Dash 3000/4000/5000 Patient Monitor
  • Empty battery doors (installed and intact)
Not Included:
  • No batteries
  • No power adapter
  • No recorder/printer
  • No ECG/SpO₂/IBP cables or sensors
  • No NIBP cuff/tubing
  • No CO₂ Sensor 
  • No rolling stand
  • No user manual
  • No accessories, disposables, or consumables

 

 

*Items shown in photos are the items that will ship.  If it is not shown in the photos, it is not included*

 

Stock ID : 38305 (P.O 4018) (WH104 SCC15

 

Comments:

Kindly enlarge the images and see them with zooming.

Concern or query: Ask a Question

Condition: Parts Only, please refer to images for cosmetic condition.

  1. 1.    Overall Condition: As seen in images : AS-IS
  2. 2.    Physical Condition: Please review images before bidding : Very Good
  3. 3.    Working Condition: Has been tested at our end | Because of the trim knob failure and unknown software configuration, the unit is being sold AS-IS / For Parts Use Only.......Will receive item as pictured…………(Offered AS IS)
  4. 4.    As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
  5. 5.    Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)