For orders, please call: 952-232-5970

$0Checkout 0 Item(s)

MENU

    

GE Dash 4000 Patient Monito...

GE Dash 4000 Patient Monitor, EKG Masimo SpO₂, NIBP, Temp, Dual IBP, Print~38721

Item specifics

Condition
Used
Seller Notes
“Pre-owned GE Dash 4000 Patient Monitor (REF 2035598-203, S/N SD007514451GA), manufactured Dec 2007, tested and fully functional for ECG, NIBP (DINAMAP® SuperSTAT), Masimo SET SpO₂, dual IBP, Temp, and Respiration."
Model
Dash 4000
MPN
2035598-203

More details


$583.20

38721

1 item in stock

Warning: Last item in stock!

Add to cart

Place an offer

Product details

Manufacturer

GE Medical Systems

Item:

 GE Dash 4000 Patient Monitor (ECG, Masimo SpO₂, NIBP, Temp, Dual IBP, Printer) W/ 2x Batteries & NEW Leads

Model/Cat #        

Dash 4000 / Ref 2035598-203

Serial No.        

SD007514451GA

Made In:             

USA

Date of Manufacture:  

12-2007

Voltage:                  100-240V 50-60Hz 2.0-1.0A

                   

Short description:

The GE Dash 4000 is a high-acuity, OR/ICU-grade patient monitor designed for critical care and transport use. This unit powers on normally, loads the clinical interface, and all installed parameters—ECG, SpO₂ (Masimo SET), NIBP, 2× IBP, Temperature, and Respiration—are active and functional. The thermal printer is installed, tested, and prints correctly.

CE Mark: CE 0459
NBP Technology: DINAMAP® SuperSTAT
SpO₂ Technology: Nellcor OxiMax®
Printer: Installed and fully functional

Software Configuration:

 

  • Admit Menu Type: Standard
  • Patient Monitor Type: Operating Room
  • Enabled Options: 2× BP, CO₂, 12SL, ACI-TIPI, Hi-Res Trends, Network, Cardio-Pulmonary, Cardiac
  • NBP: DINAMAP® SuperSTAT
Installed Parameters:
 
The monitor detects and supports the following clinical parameters:
  • ECG
  • NIBP
  • SpO₂ (Masimo SET)
  • 2× IBP (ART1, ART2)
  • Temperature (TP1)
  • Respiration (RR) – parameter present and functional; RR display was set to OFF during photos
  • Alarms
CO₂ hardware is not installed despite the software option being available.

 

 

Condition & Functionality:

Overall Condition: Good used condition with normal wear
LCD: Clear, bright, free of pixel defects
Casing:

  • Front: clean
  • Rear bezel: has several stress cracks (cosmetic; does not affect function)
  • Ports: Clean, intact, no damage
  • Handle: Solid and secure
  • Printer: Installed & working
  • CO₂: Not installed

Functional Testing:

  • Boots normally and completes self-test
  • ECG waveform stable
  • NIBP cycles and reads correctly
  • SpO₂ responds with new Masimo sensor
  • IBP ×2 channels active; IBP adapter cable included
  • Temperature channel active
  • Respiration (RR) available and functional
  • Alarms respond and adjust
  • Printer tested successfully

Cosmetic Rating: 7.5-8/10

Battery Status:

Both battery bays show NO COMM:

  • No recognized communication
  • Charge level unknown
  • Time-to-empty and time-to-full unknown
  • Battery quality unknown

Conclusion:

✔ Both batteries are dead / non-functional
✔ Replacement strongly recommended
✔ Unit operates normally on AC power

Included:
  • (1) GE Dash 4000 Patient Monitor (P/N 2035598-203)
  • (1) New NIBP Hose (REF SH3931D)
  • (1) New Adult NIBP Cuff 25–35 cm (REF SC1721-3232)
  • (1) New ECG Cable, 5-Lead SNAP AHA (REF SG5112S)
  • (1) New Masimo SET Reusable SpO₂ Sensor (REF SP9119W)
  • (1) New Reusable SpO₂ Adapter Cable – Masimo type
  • (1) New Reusable Temperature Probe – Skin Type (REF ST1304)
  • (1) USA Power Cord
  • (1) Device Stand Base Plate
  • (1) IBP Transducer Cable (no disposable pressure transducers included)
All included leads and patient-side accessories are NEW.
 
Not Included:
  • CO₂ hardware / sampling lines
  • Disposable IBP transducers
  • Printer paper rolls beyond test print
  • Additional accessories
  • Printed user manual
Shipping Note:
Weight: approx. 20 lbs
Dimensions: 18″ × 18″ × 16″
Packaging: Foam, bubble, anti-static, double-wall protection
Carrier: UPS / FedEx Ground
Handling: 1–2 business days

Advisory Note:
This is a used medical device. A biomedical inspection or PM is recommended before clinical deployment.
CO₂ hardware is not installed.
Printer is installed and functional.
Rear casing has cosmetic stress cracks.
Both batteries are non-communicative and should be replaced.

 

 

*Items shown in photos are the items that will ship.  If it is not shown in the photos, it is not included*

 

Stock ID : 38721 (P.O 4018) (R2 C7

 

Comments:

Kindly enlarge the images and see them with zooming.

Concern or query: Ask a Question

Condition: USED, please refer to images for cosmetic condition.

  1. 1.    Overall Condition:- As seen in images - Very Good
  2. 2.    Physical Condition:  Please review images before bidding - Good
  3. 3.    Working Condition: Has been tested at our end and the functionality has been shown in the image section......Will receive item as pictured ……………(Offered AS IS)
  4. 4.    As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
  5. 5.    Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)