Philips IntelliVue MX700 Sy...
Philips IntelliVue MX700 System W/ FMS & M3001 M3012A BIS REC Vent Modules~38700
Item specifics
- Used
- Model
- MX700
MPN- 865241
Product details
Manufacturer: | Philips Medizin Systeme |
Item: | Philips IntelliVue MX700 Patient Monitoring System w/ FMS Server, M3001A, M3012A, BIS, VueLink & Recorder Modules |
Model/Cat # | MX700 / 865241 |
Serial No. | DE125224944 |
Made In: | Germany |
Date of Manufacture: | 2014-05 |
Voltage: 100–240 V AC, 50–60 Hz
Short Description:
This listing includes a fully integrated Philips IntelliVue MX700 Bedside Patient Monitoring System, complete with a Flexible Module Server (FMS), Multi-Parameter Module (M3001A), Extension Module (M3012A), VueLink Module (M1032A), BIS Module (M1034B), Recorder/Printer Module (M1116B), and a full set of brand-new OEM-compatible accessories.
All equipment is Philips OEM, made in Germany, tested for boot sequence, touchscreen function, module detection, and parameter recognition. Cosmetic condition is excellent with minor surface wear consistent with standard clinical use.
Flexible Module Server (FMS):
- REF 865243 (S/N DE12334176, CE 0366, DOM: 2014-04
Recorder / Printer Module:
- Model M1116B, PN M1116-80000 (S/N 422-784-5959, DOM February 2006)
BIS Module (BIS–II Spectral Index):
- Model M1034B / 866421 (S/N DE49708503, DOM May 2018, CE 0123)
Multi-Parameter Patient Module (ECG/NIBP/SpO₂/TEMP/PRESS):
- Model M3001A, REF 862442, Option A01 C06
- (S/N DE907U1934, DOM November 2009)
Extension Module (2× Press / 2× Temp / Output):
- Model M3012A, REF 862111, Option C05
- (S/N DE83742065, DOM: 2011-06)
VueLink Module (Ventilator device Interface):
- Model M1032A (S/N 4503G28919, DOM October 2005)
Condition:
Power & Display:
- MX700 powers on normally and passes self-test.
- Bright, clear, responsive touchscreen without cracks.
Housing:
- No cracks or dents on modules or monitor.
- Light scuffs consistent with normal use.
- FMS has a small cosmetic chip on the upper-right corner—does not affect performance.
Ports & Connectors:
- All connections are verified functional.
- Module detection through FMS is stable.
Keys & Indicators:
Alarm indicators and soft keys are fully responsive.
Printer Module:
- Powers correctly; no recording paper installed (message: “Add paper”).
- Buttons and mechanism intact.
System Communication:
- All modules—M3001A, M3012A, M1032A VueLink, M1034B BIS, M1116B printer—recognized by MX700.
- Stable module-to-monitor communication throughout.
Functionality Summary:
- MX700 boots normally into Software Revision M.04.01-8.
- Modules recognized: M3001A (ECG/NIBP/SpO₂/TEMP/PRESS), M3012A (Press/Temp/Output), M1032A (VueLink), M1034B (BIS), M1116B (Printer)
- Parameter detection confirmed for: ECG, SpO₂ (Nellcor), NIBP, Temperature, Press/IBP, BIS (detected)
- VueLink module recognized and ready for device interface configuration.
- Touchscreen and trim navigation are fully functional.
- Communication stable across FMS → Modules → MX700.
System is suitable for integration into IntelliVue environments that use LAN / RS-232 / DVI communication.
What Is Included:
- Philips IntelliVue MX700 Monitor (REF 865241, DOM 05/2014)
- Philips Flexible Module Server – FMS (REF 865243)
- Philips M3001A Multi-Parameter Module (REF 862442, DOM 11/2009)
- Philips M3012A Extension Module (REF 862111)
- Philips M1032A VueLink Module (DOM 10/2005)
- Philips M1032B Parameter Module
- Philips M1034B BIS Module (DOM 05/2018)
- Philips M1116B Recorder/Printer Module (DOM 02/2006)
- ECG Cable – REF SG51245 (5-Lead)
- Reusable SpO₂ Finger Sensor (Nellcor Type) – REF SP9119A
- Adult NIBP Cuff (35 × 27 cm) – REF SE1711-11
- NIBP Hose (Single Tube) – REF SH09105
- Temperature Probe (Reusable Skin Type) – REF ST31505
- IBP Adapter Cable (Medex/Abbott Compatible) – REF SB04111
- Philips OEM Module Server→Monitor Interface Cable – REF M3081-61626
- Hospital-Grade Power Cord
What Is Not Included:
- Rolling stand or mounting trolley
- Additional extension racks or modules beyond those listed
- Disposable consumables (electrodes, IBP kits, BIS sensors, cuffs, printer paper)
- User manuals, IFUs, or calibration/PM documentation
*Items shown in photos are the items that will ship. If it is not shown in the photos, it is not included*
Stock ID : 38700 (P.O ?) (WH 77) - SHIPPING READY
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition: USED, please refer to images for cosmetic condition.
- 1. Overall Condition: As seen in images - Very Good
- 2. Physical Condition: Please review images before bidding - Very Good
- 3. Working Condition: Has been tested at our end & is in good functionality as shown in the images.....Will receive item as pictured ……………(offered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)