2016 Philips IntelliVue MX700 Monitor W/ MP2+M3012A Modules, Rack & Leads ~38259

Item specifics

Condition
Used
Seller Notes
“Philips IntelliVue MX700 Anesthesia/Bedside Monitor System (S/N: DE58544071), manufactured 2016-09-26. Fully functional and tested, includes MP2 Transport Monitor (M3002A), M3012A rack module, and 865297 charging/interface rack."
Model
MX700
MPN
865241

More details


$1,295.20

38259

1 item in stock

Warning: Last item in stock!

Add to cart

Place an offer

Product details

 

Manufacturer:

Philips Medizin Systeme

Item:

2016 Philips IntelliVue MX700 Anesthesia / Bedside Monitor W/ MP2 Module, M3012A Module, 865297 Rack & NEW Leads

Model/Cat #

MX700 / 865241

Serial No.

DE58544071

Made In: 

Germany / Romania 

Date of Manufacture:

2016-09-26

 

Voltage:                   100–240 V AC, 50–60 Hz, 1.9–0.9 A

Short Description:

This listing features a Philips IntelliVue MX700 Anesthesia / Bedside Patient Monitoring System, paired with a Philips IntelliVue MP2 Transport Monitor (M3002A) and M3012A rack module.

The unit is fully functional and tested, offering responsive touchscreen controls, verified communication between all connected components, and a mix of OEM and compatible accessories for ECG, Nellcor SpO₂, NIBP, IBP, and temperature measurement.

Philips IntelliVue MP2 Transport Monitor:

 

  • Model M3002A
  • REF 8652040
  • S/N DE03713410
  • DOM: June 2012

 

Philips IntelliVue M3012A Module:

  • REF 862111
  • S/N DE83736532
  • DOM: August 2010

 

Charging / Interface Rack:

 

  • REF 865297 
  • S/N DE43610061
  • DOM: December 2017

 

Software Versions:
  • MX700 Anesthesia Software: SW Rev L.01.08
  • MP2 Transport Software: SW Rev K.21.61

Condition:

  • Power & Display: Both MX700 and MP2 power ON and pass all internal self-tests.
  • Screens: Bright, clear, and responsive touchscreens with no cracks or significant scratches.
  • Housing: No dents, cracks, or discoloration; light cosmetic wear consistent with clinical use.
  • Ports & Connectors: All inspected and responsive; communication between MX700 and MP2 confirmed.
  • Indicators & Keys: All alarms, lights, and control buttons verified functional.
  • Battery & Power: Charging verified; battery endurance not warranted.
  • Communication: Stable via LAN, RS-232, and DVI connections.

Functionality Summary:

  • MX700 boots normally into IntelliVue Anesthesia software (SW L.01.08).
  • MP2 operates correctly in Companion Mode (SW K.21.61).
  • All primary parameters — ECG, SpO₂ (Nellcor), NIBP, IBP, and TEMP — measured accurately during testing.
  • Front keys and touchscreen responsive and calibrated.
  • Seamless data communication between modules confirmed.
  • System ready for integration in IntelliVue network environments (LAN/RS-232/DVI).

What Is Included:

  • Philips IntelliVue MX700 Anesthesia Monitor (REF 865241, DOM: 09/2016)
  • Philips IntelliVue MP2 Transport Monitor (M3002A, REF 8652040, DOM: 06/2012)
  • Philips IntelliVue M3012A Rack Module (REF 862111, DOM: 08/2010)
  • Philips IntelliVue Charging / Interface Rack (REF 865297, DOM: 12/2017)
  • ECG Cable – REF SG51245, 5-lead (Philips-compatible)
  • SpO₂ Sensor – REF SP9119A, Nellcor-compatible reusable finger sensor
  • SpO₂ Extension Cable – REF M1493A
  • NIBP Cuff – REF SE1711-11 (Adult Reusable, 35 × 27 cm, Philips-compatible)
  • NIBP Hose – REF SH09105 (Single Tube Adapter, HP/Philips-compatible)
  • Temperature Probe – REF ST31505 (Reusable Skin Type, Philips-compatible)
  • IBP Adapter Cable – REF SB04111 (Medex Abbott Transducer-compatible)
  • Philips OEM Charger-to-Monitor Interface Cable – REF M3081-61626
  • Hospital-Grade Power Cord

What Is Not Included:

  • Stand or mounting trolley
  • Additional extension modules or racks
  • Printers
  • Consumables / disposables (e.g., cuffs, electrodes, paper, or sensors beyond those listed)
  • User manuals or calibration documentation
  • *Items shown in photos are the items that will ship.  If it is not shown in the photos, it is not included*

     

    Stock ID : 38259 (P.O 4018) (WH 77) - SHIPPING READY

     

    Comments:

    Kindly enlarge the images and see them with zooming.

    Concern or query: Ask a Question

    Condition: USED, please refer to images for cosmetic condition.

    1. 1.    Overall Condition: As seen in images - Very Good
    2. 2.    Physical Condition: Please review images before bidding - Very Good
    3. 3.    Working Condition: Has been tested at our end & is in good functionality as shown in the images.....Will receive item as pictured ……………(offered AS IS)
    4. 4.    As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
    5. 5.    Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)