Philips IntelliVue MX700 Mo...
Philips IntelliVue MX700 Monitor W/ X2 Transport, M3012A Module & Leads ~ 38636
Item specifics
- Used
- Model
- MX700
MPN- 865241
Product details
Device Information:
| Specification | Detail |
|---|---|
| Manufacturer | Philips Medizin Systeme Böblingen GmbH |
| System Configuration | IntelliVue MX700 Anesthesia / Bedside Monitor with X2 Transport Monitor and Extension Module |
| MX700 Reference (REF) | 865241 |
| MX700 Serial Number (S/N) | DE12511681 |
| MX700 Date of Manufacture (DOM) | March 2013 |
| X2 Transport Monitor Model | M3002A |
| X2 Serial Number (S/N) | DE5332029 |
| X2 Date of Manufacture (DOM) | September 2009 |
| Extension Module Reference (REF) | M3012B |
| Voltage Requirement | 100–240 V~ 50/60 Hz, 1.9–0.9 A |
| Regulatory Mark | CE 0086 |
| Country of Manufacture | Germany |
| Display Type | 15" color TFT LCD touchscreen |
| Installed Parameters (X2) | ECG, NIBP, SpO₂ (Nellcor-type), TEMP ×2 |
| Interfaces / Ports | RS-232, LAN, DVI, Nurse Call, Analog Out |
| Software Version (MX700) | SW J.10.26 |
| Software Version (X2) | SW K.21.42 |
| Charging / Docking Interface | IntelliVue Rack REF 865297 (2017-08) with M4605A & M4607A Li-Ion Batteries |
Short Description:
The Philips IntelliVue MX700 Anesthesia / Bedside Patient Monitor paired with the Philips IntelliVue X2 Transport Monitor (M3002A) offers a fully integrated solution for continuous and transport monitoring.
The MX700 provides a large, high-resolution touchscreen for anesthesia and critical care applications, while the X2 acts as a detachable transport unit, carrying core parameters (ECG, NIBP, SpO₂, TEMP ×2) and seamlessly reconnecting to the MX700 for full functionality.
This unit includes an extension module (M3012A) and a Philips IntelliVue charging rack (865297, 2017-08) with verified batteries.
Condition Summary:
- Both MX700 and X2 power ON and pass all internal self-tests.
- Touchscreens are bright and responsive with clear waveforms and no pixel defects.
- Communication between MX700 and X2 verified; all displayed parameters sync correctly.
- Extension Module (M3012A) recognized and functional; supports dual temperature channels (TEMP ×2, 2XPRESS)
- ECG and NIBP parameters tested and working.
- SpO₂ (Nellcor) and TEMP parameters present but untested.
- Batteries installed, hold charge; overnight charging recommended before use.
- No warranty on used batteries.
- MX700 housing chipped at both upper right and upper left corners.
- X2 Transport Monitor chipped on one corner (see images).
- Extension Module (M3012A) slightly cracked at upper right corner (cosmetic only).
- Rear cable holder cover is missing.
- All menu functions, alarm indicators, and navigation buttons working properly.
- Ports and connectors inspected—no bent pins or loose terminals.
- Overall cosmetic condition: Good, with minor surface wear and cosmetic chips as noted.
Functionality Summary:
- MX700 monitor boots to IntelliVue Anesthesia interface (SW J.10.26).
- X2 Transport Monitor operates normally in Companion Mode (SW K.21.42).
- ECG and NIBP tested functional.
- SpO₂ (Nellcor-type) and TEMP ×2 available but untested.
- Touchscreen and hardware controls fully responsive.
- System ready for LAN / RS-232 / DVI communication.
- Battery charging verified (endurance not warranted).
What’s Included:
- Philips IntelliVue MX700 Monitor (REF 865241, S/N DE12511681, DOM Mar-2013)
- Philips IntelliVue X2 Transport Monitor (Model M3002A, S/N DE5332029, DOM Sep-2009)
- Philips IntelliVue Extension Module (REF M3012A, dual TEMP channels)
- Philips IntelliVue Charging Rack / Dock (REF 865297, 2017-08)
- Two Philips Li-Ion Batteries (M4605A and M4607A – used, hold charge)
- Philips OEM Charger-to-Monitor Interface Cable (M3081-61626 / REF 453563474781)
New compatible accessories (OEM or equivalent):
ECG Cable – REF SG51245 (5-Lead, Philips-compatible)
SpO₂ Finger Sensor – REF SP9235 (Reusable, Nellcor-type)
NIBP Cuff – REF SC7211 (Adult Reusable, 35 × 27 cm)
Temperature Probe – REF ST31505 (Reusable Skin Type)
NIBP Adapter Hose – REF SH09105 (Single Tube, HP/Philips-compatible)
Hospital-grade power cord
What’s Not Included:
- User manual or service documentation
- Rolling stand, cart, or mounting hardware
- Printer, recorder, or expansion bay
- External network/computer accessories
- Disposable consumables or additional software licenses
Additional Note:
No warranties are provided for the included used batteries.
They have been tested to hold charge but endurance is not guaranteed.
Users are advised to fully charge overnight and replace before clinical use.
Items are tested, functional, and accurately described per photographs.
*Items shown in photos are the items that will ship. If it is not shown in the photos, it is not included*
Stock ID : 38636 (P.O 1200 / 4017) (WH 77) - SHIPPING READY
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition: USED, please refer to images for cosmetic condition.
- 1. Overall Condition: As seen in images - Very Good
- 2. Physical Condition: Please review images before bidding - Good
- 3. Working Condition: Has been tested at our end & is in good functionality as shown in the images.....Will receive item as pictured ……………(offered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)