Philips MP50 Patient Monito...
Philips MP50 Patient Monitor W/ CO2+MMS, Print, Press, Temp Module & Leads~38235
Item specifics
- Used
- Model
- MP50
MPN- M8004A
Product details
Manufacturer | Philips Healthcare |
Item: | Philips MP50 Intellivue Patient Monitor W/ MMS+CO2, Print, Pressure, Temp Module & Leads |
Model/Cat # | MP50 / M8004A |
Serial No. | DE44022835 |
Made In: | Germany |
Date of Manufacture: | 2005-12 |
Voltage: 100-240V 50-60Hz 1.8-1.0A
Short description:
This is a reliable Philips MP50 Intellivue Patient Monitor with MMS, Print, Pressure, and Temperature modules. Includes ECG leads, new SpO2 sensor, NBP accessories, Temp probe, and power cord. LCD responsive, all key functions tested and working. CE# 0366.
Specifications & Condition:
Software Version: L.01.21
Battery: Not Installed
Parameters: ECG, SpO2 (Masimo), NBP, Temp, IBP & CO2
Options: H30, A06, C01, C02, C15, C20
Printer: Installed & Working | Paper is included | Cover is damaged
LCD: Responsive but dull | Has some minor scratches
Handle: Intact
Trim Knob: Working but worn out
Softpads: Working
Dents or cracks: Some noted on top & side of the unit; see images
Scratches or scuffs: Minor cosmetic wear present
Logo Emblem: Intact
Connectivity & ports: LAN port available
Philips M3001A MMS Module:
- SN# DE9070BEA4
- DOM: 2012-10
- Options: A03C12
- Module has been tested and is functioning properly
Philips M3015A Microstream C02 Extension Module:
- SN# DE02003845
- Refurbished: 2010-05
- Options: C06
- Module has been tested and is functioning properly
Philips HP M1029A Temperature Module:
- SN# 3731A31397
- Options: ABA
- DOM: 09-1997
Philips M1006B Press Module:
- P/N: M1006B-69601
- SN# 3805G51929
- DOM: 07-2006
Philips M1116B Print Module:
- SN# 4227A35912
- DOM: 2004-10
- Module is missing its top cover
Included:
- 2005 Philips MP50 Intellivue Patient Monitor
- Philips M3001A MMS Module
- Philips M3015A Microstream C02 Extension Module
- Philips HP M1029A Temperature Module
- Philips M1006B Press Module
- Philips M1116B Print Module
- ECG Cable W/ Leads (Used)
- SpO2 Sensor Ref SP9325B - Type Masimo (New)
- NBP Hose Ref SH0910S (New)
- NBP Adult Cuff Ref SC2711-11 (New)
- Temperature Probe Ref ST1305 (New)
- Power Cord
- Stand
- User Manual
- IBP Leads/Transducers
- CO₂ Cable/Transducers
*Items shown in photos are the items that will ship. If it is not shown in the photos, it is not included*
Stock ID : 38235 (P.O 4014) (WH104 SCC12)
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition: USED, please refer to images for cosmetic condition.
- 1. Overall Condition: As seen in images - Good
- 2. Physical Condition: Please review images before bidding - Good
- 3. Working Condition: Has been tested at our end & is in good functionality as shown in the images.....Will receive item as pictured ……………(offered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)