GE Solar BIS Module (200418...
GE Solar BIS Module (2004182-001) + DSC-XP Module (185-0124) W/ PIC ~ 38001
Item specifics
- Used
- 2004182-2004182-001
- 2004182-001
Product details
Manufacturer | GE Healthcare |
Item: | GE Solar BIS Module (2004182-001) + Aspect DSC-XP BIS Module (REF 185-0124) W/ Patient Interface Cable |
Model/Cat # | 2004182-001 | 185-0124 |
Serial No. | See Below |
Made In: | USA |
Date of Manufacture: | 2007 |
Short description:
This listing is for one individual set comprising of:
- 1× GE Solar BIS (EEG) Module (P/N 2004182-001)
- 1× Aspect Medical DSC-XP BIS Module (REF 185-0124) with integrated cable
- 1× Patient Interface Cable (approx. 4 ft)
These modules are used with GE Solar monitoring systems for BIS (Bispectral Index) depth of anesthesia monitoring. Each set is in good cosmetic condition, with no dents or cracks, though light scratches/scuffs may be present.
DOM (Date of Manufacture): Solar BIS Modules – 03/2007 or 08/2007; DSC-XP BIS Modules – 2001–2007
Available Sets (EEG Module + DSC-XP BIS Module):
| No. | EEG Module Serial # | EEG DOM | DSC-XP Module Serial # | DSC-XP DOM |
|---|---|---|---|---|
| 1 | RBM07131635GA | 03-2007 | D40306 | 2001 |
| 2 | RBM07131636GA | 03-2007 | DX1655 | 2001 |
| 3 | RBM07331788GA | 08-2007 | DX7284 | 2002 |
| 4 | RBM07131630GA | 08-2007 | DX6238 | 2002 |
| 5 | RBM07131629GA | 03-2007 | DX14486 | 2003 |
| 6 | RBM07131639GA | 03-2007 | DX31044 | 2006 |
| 7 | RBM07131628GA | 03-2007 | DX30790 | 2006 |
| 8 | RBM07331787GA | 08-2007 | DX37876 | 2007 |
| 9 | RBM07131638GA | 03-2007 | DX37825 | 2007 |
| 10 | RBM07131637GA | 03-2007 | DX37623 | 2007 |
| 11 | RBM07136416GA | 03-2007 | DX38064 | 2007 |
| 12 | RBM07131627GA | 03-2007 | DX37601 | 2007 |
Note for Clients: The devices will be shipped randomly unless a specific serial number is requested. If the selected set has already been sold, another available set can be provided upon request.
- Good cosmetic condition.
- No dents or cracks, may have light scratches or scuffs.
- Back connector pins intact, BIS port clean.
- Module extraction latches intact and functional.
- Good cosmetic condition.
- Integrated BIS cable approx. 12 ft, no cuts or tears, connectors intact.
- Patient interface cable approx. 4 ft, intact and without damage.
- These devices have not been tested with a Solar monitor.
- Functionality of DSC-XP BIS modules has not been confirmed.
- Offered as-is, based on cosmetic condition only.
- Sensors/electrodes
- GE Solar monitor
- User manuals
- Additional consumables or accessories
Package includes:
1× GE Solar BIS Module (P/N 2004182-001)
1× Aspect DSC-XP BIS Module (REF 185-0124) with integrated cable (~12 ft)
1× Patient Interface Cable (~4 ft)
*Items shown in photos are the items that will ship. If it is not shown in the photos, it is not included*
Sterilized : Non-sterile
Manual : Not Included
Cleaned : Yes, at our facility
Shipping Weight : 10 lbs
Stock ID : 38001 (P.O 2016) (SC 3)
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition: USED, please refer to images for cosmetic condition.
- 1. Overall Condition: As seen in images - Very Good
- 2. Physical Condition: Please review images before bidding - Very Good
- 3. Working Condition: Remain untested at our end....Will receive item as pictured………(Offered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)