2012 Philips MP70 (M8007A) ...
2012 Philips MP70 (M8007A) Patient Monitor W/ MMS Module & Leads ~ 37563
Item specifics
- Used
- Model
- MP70
MPN- 862451
Product details
Manufacturer | Philips Healthcare |
Item: | 2012 Philips MP70 (M8007A) Patient Monitor W/ MMS Module & Leads |
Model/Cat # | MP70 / M8007A / Ref 862451 |
Serial No. | DE843B4587 |
Made In: | Germany |
Date of Manufacture: | 2012-01 |
Voltage: 100-240V 50-60Hz 1.8-1.0A
Short description...
*Sale is for imaged items only.
*Signs of moderate use.
*Has been tested at our end & is in good functionality as shown in the images.
*Sale comprises of:
-Intellivue MP70 (M8007A) Patient Monitor
-Ref M3001A MMS Module
-Patient Leads
*Modules:
-1X M3001A MMS Module | Ref 862442 | SN# ?| DOM: ?
Optional extension modules can be added as per your requirement.
The secondary slot supports compatible modules such as a printer, BIS, IBP, or others.
*Parameters: Temp, NBP, SpO2 , ECG & IBP
*LCD: In good shape, touchscreen
*Dents/Cracks: None noted
*Scratches/Scuffs: Yes, maybe
*Softpads: Working
*Date & Time: Date is correct, time can be adjusted as per the time zone
*Patient Leads:
-SpO2 Reusable sensor Direct type Nellcor Ref SP9325B (New)
-ECG Cable W/ Leads (New)
-Ref SH0910S NBP Hose W/ Cuff SC1711-11 (Both New)
-IBP Adapter Cable Ref SB0211 (New)
-Temp Probe Ref ST1305 (New)
*No IBP transducer included
*Disposables or consumables: N/A
*Power Cord: Included
*Stand: Not Included
*Manual: Not Included
*Please review images and check for compatibility before bidding for the item
Package includes:-
2012 Philips MP70 (M8007A) Patient Monitor
1X M3001A MMS Module | Ref 862442
SpO2 Reusable sensor Direct type (New)
ECG Cable W/ Leads new
Ref SH0910S NBP Hose W/ Cuff SC1711-11 (Both New)
IBP Adapter Cable Ref SB0211 (New)
Temp Probe Ref ST1305 (New)
Power Cord
*Items shown in photos are the items that will ship. If it is not shown in the photos, it is not included*
Sterilized : Non-sterile device
Manual : Not included
Cleaned : Yes, at our facility
Shipping Weight : 30 lbs
Stock ID : 37563 (P.O 4041) (WH104 SCC9)
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition: USED, please refer to images for cosmetic condition.
- 1. Overall Condition: As seen in images - Good
- 2. Physical Condition: Please review images before bidding - Good
- 3. Working Condition: Has been tested at our end & is in good functionality as shown in the images...Will receive item as pictured…………(Offered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)