For orders, please call: 1-952-953-0653

$0Checkout 0 Item(s)

MENU

    

GE Datex Ohmeda Desflurane ...

GE Datex Ohmeda Desflurane Tec 6 Vaporizer ~ 17894

Item specifics

Condition:Used : 
 Notes:Unit may have a few scratches on it / may be slightly smudged / No dents or cracks observed / Low agent, needs refilling / overall enjoys good cosmetics
Model:

Tec 6

MPN:

X1107-9101-000

Country/Region of Manufacture:United KingdomBrand:

GE Datex Ohmeda

More details


$208.00

17894

Availability: This product is no longer in stock.

Product details

Manufacturer

GE Datex Ohmeda

Item:

GE Datex Ohmeda Desflurane Tec 6 Vaporizer 

Model/Cat #        

Tec 6 /  

Serial No.        

ACTW46090

Made In:             

England, U.K

Date of Manufacture:  

N/A

Voltage: 100-120V 2.0A 50-60Hz

                   

Short description...

  1. 1.      Sale is for imaged items only.
  2. 2.   Signs of average use
  3. 3.   Battery and the agent, both seem to be low

     *No sign of dents or cracks have been observed but is slightly smudged/yellowed

     *Please note that this is Tec 6 Vaporizer, not the Tec 6 Plus.

     *Isn't calibrated, therefore you may need to calibrate it prior to use

     *Is displaying the 'Low Agent Level'. This means that there is less than 60ml of agent remaining in the sump and agent should be added. Once the agent is added, the vaporizer should work perfectly fine.


Know Your Product:


The Tec 6 is an electronic vaporizer which heats Desflurane to maintain constant temperature and vapor pressure for consistent output. It has an LED display which indicates vaporizer status - no output, low agent, warm-up, operational and alarm battery low. The Tec 6 also features several intrinsic vaporizer monitors and alarms that constantly monitor vaporizer status. 

The Tec 6 manages alarm priorities and offers improved tonal quality for alarm audio sounds while conveying alarm importance in sound sequence, visual color and flash rate. In addition, a distinctive audio tone will sound when the vaporizer can no longer deliver agent because AC power is disconnected. The Tec 6 incorporates a self-test system which checks a range of conditions each time the unit is turned on. 

The Tec 6 attaches to Datex-Ohmeda's interlocking Selectatec Manifold allowing clinicians to change vaporizer arrangement from case-to-case or move vaporizers from suite-to suite without the need for tools.

For further details refer to the vendor's issued manual linked below:

[link removed by eBay]


     

      

      

 

             

 

    Package includes:-


GE Datex Ohmeda Ref X1107-9101-000 Desflurane Tec 6 Vaporizer 


 

*Items shown in photos are the items that will ship.  If it is not shown in the photos, it is not included*


  1. 6.        Sterilized No
  2. 7.        Manual : No
  3. 8.        Cleaned : Yes
  4. 9.        Shipping Weight  : 16 lbs

 

Stock ID : 17894 (R2C1)

 

 

 

Comments:

Kindly enlarge the images and see them with zooming.

Concern or query: Ask a Question

Condition: USED, please refer to images for cosmetic condition.

  1. 1.    Overall Condition:- As seen in images  - Good
  2. 2.    Physical Condition:  Please review images before bidding : Good
  3. 3.    Working Condition: Unit powers on, is displaying low battery and low agent alarm, rest remains untested for further details ...will receive item as pictured ……………(offered AS IS)
  4. 4.    As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
  5. 5.    Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)
  6. 6.    Caution for Buyers:

DESPITE WHAT MAY BE WRITTEN IN THIS LISTING ALL ITEMS ARE SOLD 'AS IS' & 'WHERE IS' AND UNLESS THE SELLER HAS INDICATED OTHERWISE, THERE WILL BE NO REFUND.

Please make sure you are ready to buy if you decide to place a bid.

Available Documentation (manual etc.): nil

Accessories: Comes with everything you see in pictures nothing more nothing less.

Added note:  Completely check out item/s prior to use in conjunction with patient care and seller will not take any responsibility for its use on patient.

Maintenance & Certification: - Strongly recommended.

Useful tips: do not scratch or apply sticking plasters.

Seller does not fix or repair any items to make them usable.

If item is listed for parts only, it is specifically mention in the listing as well.