GE C551 Curved Array Transducer Probe For GE Logiq 400 & 500 Systems~ 16662

Item specifics

Condition:For parts or not working : 
Notes:Review images for cosmetics, ....Air scan : Shadows , Phantom Scan : Dead elements , Organ scans : Bad image
Brand:

GE

Country of Manufacture:United States
Model:

C551

Intended Use/Discipline:Obstetrics & Gynecology

More details


$36.00

16662

Availability: This product is no longer in stock.

Product details

Manufacturer :

 

GE Medical corp

Item:

 

GE C551 P/N 9607AD Convex Array Transducer  for GE Logiq 400 & 500 Systems 

Model/Cat #

 

P9607AD / C551

Serial No.

 

357816YM8

Made In:

 Japan

Date of manufacture

 

8/1996

 

Voltage             : NA     

 

Short description……………….

  1. 1.     Sale is for imaged item only
  2. 2.     Applications :  for abdominal and OB-GYN applications
  3. 3.     Frequency :                                           5.0 / D4.0  MHz 
  4. 4.     Systems :   compatible with GE Logiq 400 and Logiq 500 , Vivid 3 and 4 ultrasound systems. 
  •            
  •  4.0-7.0Mhz
  • Convex

Note: Please note that provided info are for guidance purpose only and does not constitute a professional advice. Please verify the compatibility of the system yourself before committing to buy

  1. 5.     Probe analysis

Connector : no dents cracks or bent pins, some scratches

Lock : looks good

Cable : No cuts or tears 

HEAD AND handle : No dents and cracks, membrane appears to be nice ,  may have few scratches on the handle 


SCAN ANALYSIS :

 Air scan : Shadows 

Phantom Scan : Dead elements 

Organ scans : Bad image 

  1. Manual : No
  2. Case : No
  3. Cleaned : Yes
  4. Sterilized : No
  5. Shipping Weight: 7 lbs.
  6. Stocks ID:  16662~WH555
 

 

Comments:

Kindly enlarge the images and see them with zooming.

Concern or query: Ask a Question

Condition:

  1. 1.  Overall Condition:- As seen in images  : As Is ~ No Returns 
  2. 2.   Physical Condition:  Please review images before bidding - Good 

 

  1. 3.   Working Condition:   

Air scan : Shadows 

Phantom Scan : Dead elements 

Organ scans : Bad image   ……We do not comment on the functionality of  used probes, please review the images and take your own decision ............For Parts ..........................(offered AS IS)

  1. 4.  “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
  2. 5.  Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)
  3. 6.  Caution for Buyers:

DESPITE WHAT MAY BE WRITTEN IN THIS LISTING ALL ITEMS ARE SOLD 'AS IS' & 'WHERE IS' AND UNLESS THE SELLER HAS INDICATED OTHERWISE, THERE WILL BE NO REFUND.

Please make sure you are ready to buy if you decide to place a bid.

 Available Documentation (manual etc.): nil

Accessories: Comes with everything you see in pictures nothing more nothing less.

Liability Disclaimer Before administering any treatment or procedure to a patient you should become acquainted with the operating procedures for each mode of treatment available, as well as the indications, contraindications, warnings and precautions. Consult other resources for additional information regarding the application of this device.

Added note:  Completely check out item/s prior to use in conjunction with patient care and seller will not take any responsibility for its use on patient.

Maintenance & Certification: - Strongly recommended.

Useful tips: do not scratch or apply sticking plasters.

Seller does not fix or repair any items to make them usable.