For orders, please call: 1-952-953-0653

$0Checkout 0 Item(s)

MENU

    

2006 Biosense Webster Stock...

2006 Biosense Webster Stockert 70 Cardiac Ablation RF Generator ~16029

Item specifics

Condition:
Used: An item that has been used previously. The item may have some signs of cosmetic wear, but is fully ... Read more
Model:

Stockert 70

MPN:

Stockert 70

Country/Region of Manufacture:Germany
Brand:

Biosense Webster

More details


$236.00

16029

Availability: This product is no longer in stock.

Product details

Manufacturer :

 

Biosense Webster

Item:

 

Biosense Webster Stockert 70 RF Generator Console For Cardiac Ablation

Model/Cat #

 

Stockert 70

Serial No.

 

ST-1920

Made In:

 

Germany 

Date of manufacture

 

2006/06

Short description……………….

Pre-owned item

  1. 1.    Sale is for Imaged item only 
  2. 2.       Package includes :

Biosense Webster Stockert 70 RF Generator 

Power Cord 

  1. 3.      What is it? 

      The STOCKERT 70 RF Generator system consists of a high energy generator and other equipment used to destroy areas of heart tissue that cause abnormal heart rhythms. The generator is used with a thin hollow tube called a catheter. The generator controls the temperature at the tip of the catheter, and monitors electrical signals from the heart.

  1. 4.       How does it work? Along with a catheter, the STOCKERT 70 RF Generator allows the physician to locate the sites in the heart that give rise to, or support, abnormal heart rhythms. The abnormal sites are found by mapping the electrical signals of the heart. A type of energy called radiofrequency (RF) is delivered to the heart muscle to destroy tissue that creates abnormal heart rhythms. The generator delivers up to 50 watts of electrical power for 60-90 seconds through the catheter tube to the location in the heart that requires treatment. This energy heats the targeted heart tissue and causes a burn (ablation) that will prevent erroneous heart rhythms.

                When is it used? The STOCKERT 70 RF Generator is used for cardiac ablation procedures. Cardiac ablation is frequently      used as an alternative to chronic drug treatment of abnormal heart rhythms.

                 What will it accomplish? Help stop abnormal heart rhthyms that may be causing palpitations, lightheadedness, or chest pain.

  1. 5.       Voltage : 100-240V, 50/60Hz, 184A
  2. 6.       Output Power : 70/50W, 100 ohm,    Frequency : 500Kh
  3. 7.    No Global port or Catheters 

No case

No foot withch , no cables 

  1. 8.    Signs of average use 
  2. 9.       Manual: NO
  3. 10.   Sterilized: NO
  4. 11.   Cleaned : yes
  5. 12.   Extra Parts: No
  6. Shipping weight : 20 Lbs

 

Stocks ID:  16029 ~ SC18

Comments:

Kindly enlarge the images and see them with zooming. -

Concern or query: Ask a Question

Condition:

  1. 1.  Overall Condition:- As seen in images – Very Good
  2. 2.  Physical Condition:  Please review images before bidding – Very Good
  3. 3.  Working Condition:  Powers on , passed self test ...., Device is ready ...... otherwise untested / no way to test– being offered AS IS
  4. 4.   “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
  5. 5.  Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)
  6. 6.  Caution for Buyers:

DESPITE WHAT MAY BE WRITTEN IN THIS LISTING ALL ITEMS ARE SOLD 'AS IS' & 'WHERE IS' AND UNLESS THE SELLER HAS INDICATED OTHERWISE, THERE WILL BE NO REFUND.

Please make sure you are ready to buy if you decide to place a bid.

 Available Documentation (manual etc.): nil

Accessories: Comes with everything you see in pictures nothing more nothing less.

Added note:  Completely check out item/s prior to use in conjunction with patient care and seller will not take any responsibility for its use on patient.

Maintenance & Certification: - Strongly recommended.

Useful tips: do not scratch or apply sticking plasters.

Seller does not fix or repair any items to make them usable.

If item is listed for parts only, it is specifically mention in the listing as well.

text/x-generic footer.tpl ( UTF-8 Unicode text )