For orders, please call: 952-232-5970

$0Checkout 0 Item(s)

MENU

    

2x 3M Bair Hugger 700 Serie...

2x 3M Bair Hugger 700 Series 750 775 WARMER Hose W/ Blanket Clamp AS-IS ~ 40780

Item specifics

Condition
For parts or not working
Seller Notes
“Lot of 2 3M Bair Hugger 700 Series warming hose assemblies, configuration consistent with REF 90046, including sensor cables, connectors, retaining collars, swivel adapters, and blanket holding clamps.Hose Lot 154764: Two visible tears/splits near the warmer-side end."

More details


$92.00

40780

1 item in stock

Warning: Last item in stock!

Add to cart

Place an offer

Product details

3M Bair Hugger 700 Series Warming Hoses w/ Sensor & Clamp – Lot of 2 – AS-IS

Item Overview
Lot of 2 pre-owned 3M Bair Hugger 700 Series patient warming hose assemblies, configuration consistent with replacement hose REF 90046, for compatible Models 750/775.
Each hose includes a sensor cable with electrical connector, warmer-side retaining collar, blanket-side swivel adapter, and blanket holding clamp.
Both hoses have visible tears/splits in the outer covering. One hose additionally exhibits localized internal support-wire deformation. Sold AS-IS / untested.

Device Information
Manufacturer: 3M / Bair Hugger | Series: 700 Series
Item: Patient Warming Hose Assembly | Quantity: 2
Reference: 90046 (Configuration-Based / Unverified) | Models: 750 / 775
Sensor Cable REF: 78-8083-5031-4 | Hose Lots: 154764 / 750077
Hose Type: White Corrugated Air Hose | Condition: Pre-Owned / AS-IS
Sensor Connection: 7-Pin Connector | Sensor Cables: 2 Included
Warmer End: Retaining Collar | Blanket End: Swivel Adapter
Blanket Holding Clamps: 2 Included | Testing: Visual Inspection Only

Condition & Inspection
Hose 1 – Lot 154764

  • Two visible tears/splits in the outer hose covering near the warmer-side end.
  • One smaller tear and one comparatively larger tear.
  • Both damaged areas marked with red marker and photographed.
  • Internal coiled support structure appears generally intact on visual inspection.
  • Some surface spots, discoloration, and signs of previous use.

Hose 2 – Lot 750077

  • One pronounced tear/split near the warmer-side end.
  • Additional tear/split near the blanket-side swivel adapter.
  • Both damaged areas marked with red marker and photographed.
  • Localized deformation involving approximately 2–3 internal support-wire turns in the middle portion of the hose.
  • Normal surface wear and discoloration.

Both hoses retain their sensor cables, connectors, retaining collars, swivel adapters, and blanket holding clamps.

Functional Testing
Visual inspection only. No electrical, sensor, airflow, leakage, or temperature testing performed.
Functional condition, hose integrity, airtightness, and sensor operation remain unknown.

Included

  • 2 Bair Hugger warming hose assemblies
  • 2 Sensor cables with 7-pin connectors
  • 2 Warmer-side retaining collars
  • 2 Blanket-side swivel adapters
  • 2 Blanket holding clamps

Not Included
Warming units, warming blankets, manuals, or additional accessories.

Buyer Advisory
SOLD AS-IS / FOR PARTS OR REPAIR.
Both hoses have visible tears/splits in the outer covering. Lot 750077 additionally exhibits localized internal support-wire deformation. All identified defects are marked in red and shown in the photographs.

Hose integrity and airtightness are compromised or potentially compromised and have not been tested. Functional performance, sensor operation, and operational safety remain unverified.

Buyers are requested to carefully review all photographs, particularly the red-marked areas showing the tears/splits and support-wire deformation.

REF 90046 identification and Model 750/775 compatibility are configuration-based and have not been independently verified.

Sale includes the exact two hose assemblies pictured.

Stock ID: 40780 (P.O. 4017) (WH22) 

Purchase Terms & Buyer Protections

Condition & Use Notice

Condition: Overall, cosmetic, and functional condition are described in the listing above; please review all images carefully.
Functionality: Sold as described in the listing, or untested if stated. Biomed evaluation is recommended where applicable.
Included: Only items shown in photographs or specifically stated in the listing are included.
Buyer Responsibility: Buyer is responsible for verifying compatibility, suitability, and obtaining inspection, calibration, maintenance, or service as appropriate prior to use.