10x Drager Infinity M300 Te...
10x Drager Infinity M300 Telemetry MS26076 w/ 10 Bay Central Charger ECG ~ 40724
Item specifics
Product details
Dräger Infinity M300 Telemetry System w 10-Bay Central Charger – Lot of 10
Item Overview
Complete lot consisting of 1 Dräger/Microsun Infinity M300 10-bay Central Charger populated with 10 Dräger Infinity M300 telemetry devices. Nine M300 units include 5-lead ECG patient cable/lead sets.
The telemetry devices have been separated into three condition groups based on our basic testing. Six units tested well with batteries holding charge after overnight charging, three operate while docked but have weak/depleted batteries, and one does not power on.
Central Charger
Manufacturer: Microsun / Dräger Medical
REF / Model: MS17696-03
Type: Infinity M300 Central Charger
S/N: 10189D
DOM: 2007
Microsun P/N: 980039
Capacity: 10 charging bays
Input: 100–240 VAC • 3.5 A • 50–60 Hz
Output: 5 VDC • 1.3 A per bay
Made in: USA
Central charger powers on with green indicator illuminated. All 10 bays are populated. No major dents or cracks observed. Includes power cord.
Infinity M300 Telemetry Devices
Manufacturer: Dräger Medical Systems, Inc.
Model: Infinity M300
REF: MS26076 series
Protection: IPX7
Display: Color LCD
Monitoring: ECG / Heart Rate; SpO₂ capability
Connectivity: Wireless telemetry / Wi-Fi
Battery: Rechargeable internal lithium-ion
ECG Configuration Included: 5-lead patient cable/lead set on 9 units
Dräger documentation identifies the M300 as a wireless telemetry monitor with ECG and optional SpO₂ capability, a color LCD and rechargeable battery. Dräger
Group 1 – 6 Units / Good Basic Function
| REF | Serial Number | DOM |
|---|---|---|
| MS26076 | 5753241166 | 2019-11-24 |
| MS26076 | 5753131960 | 2018-06-27 |
| MS26076-04 | 5751741958 | 2013-02 |
| MS26076-04 | 5751937388 | 2013-11 |
| MS26076 | 5753165569 | 2018-08-27 |
| MS26076 | 5752072466 | 2014-06 |
These six units were charged overnight on the central charger. Batteries accepted/held charge during our testing. Each was connected to its ECG lead set and patient simulator, and ECG waveform/signal was observed.
Group 2 – 3 Units / Weak or Depleted Batteries
| REF | Serial Number | DOM |
|---|---|---|
| MS26076-04 | 5751937257 | 2012-11 |
| MS26076-04 | 5753346953 | 2019-05-06 |
| MS26076-04 | 5751958065 | 2013-12 |
These units have weak/depleted batteries. They were tested while seated on the central charger with ECG leads connected to a patient simulator, and ECG waveform/signal was observed. Battery replacement/service should be anticipated.
Group 3 – 1 Unit / Non-Working
REF: MS26076-06
S/N: 5752072270
DOM: 2014-06
Unit does not power on and does not include an ECG patient cable/lead set. No further functional testing performed.
Condition & Testing
- Central Charger: Powers on; green indicator illuminated
- Group 1: 6 units charged overnight and produced ECG signal during simulator testing
- Group 2: 3 units produced ECG signal while docked; batteries weak/depleted
- Group 3: 1 unit does not power on
- Displays: LCDs generally bright and clear with no significant scratches observed
- Controls: Front soft-key/button pads responsive during basic testing
- ECG: Basic simulator testing performed on 9 functioning units
- SpO₂: Capability present; SpO₂ functionality was not tested and no SpO₂ sensors are included
- Testing Level: Basic functional testing only; no comprehensive biomedical or clinical performance testing performed
Included
1× Dräger/Microsun MS17696-03 10-Bay Central Charger
10× Dräger Infinity M300 Telemetry Devices
9× 5-Lead ECG Patient Cable/Lead Sets
1× Central Charger Power Cord
Not Included
SpO₂ sensors/cables • ECG cable/lead set for the non-working M300 • Infinity CentralStation • Additional accessories • User manuals
Buyer Advisory
Pre-owned medical equipment. Units have varying functional and battery conditions as individually disclosed above. Testing was limited to basic power, charging and ECG simulator checks. SpO₂ was not tested. Battery runtime/capacity was not formally measured. Buyer should review the serial-number-specific condition and perform appropriate inspection, servicing and validation before clinical use.