For orders, please call: 952-232-5970

$0Checkout 0 Item(s)

MENU

    

USMI SS-200E Canady Plasma ...

USMI SS-200E Canady Plasma Electrosurgical Unit Argon 2 Cart Footswitch ~ 39376

Item specifics

Condition
Used
Seller Notes
“Pre‑owned USMI Canady Plasma electrosurgical system (SS‑200E ESU + Argon 2 coagulator, DOM 2011, SN 00426) mounted on rolling medical cart. Unit powers on, passes self‑test, reaches standby/active modes."
Model
SS-200E
MPN
SS-200E

More details


$2,019.20

39376

1 item in stock

Warning: Last item in stock!

Add to cart

Place an offer

Product details

Device Profile

Manufacturer: US Medical Innovations (USMI)
Item: Canady Plasma Electrosurgical System w/ Argon 2 Coagulator & Mobile Cart
Electrosurgical Unit Model: SS-200E
Argon Plasma Coagulator: Argon 2
Year: 2011     
Serial Number: 00426
Power Requirements: 100–240 VAC, 50/60 Hz, Auto-Select
Maximum Power: 625 VA


Short Description

USMI Canady Plasma electrosurgical system comprising the SS-200E Microprocessed Electrosurgical Unit paired with the Canady Plasma Argon 2 coagulator module. System is mounted on a mobile medical cart and includes dual footswitch pedal, argon tank hose assembly, patient pad adapter cable, integrated accessory tray, foldable side tray, and hospital-grade bifurcated power cord assembly.

Designed for advanced electrosurgical and plasma coagulation procedures with support for Pure Cut, Blend, Spray Coagulation, Bipolar, and E-Cut operational modes.

Quick Condition Overview

Cosmetics: Very Good
Functional Status: Powers On & Passes Self-Test
Operational State: Reaches Standby / Active Modes
Completeness: Includes cart, footswitch, and patient pad adapter as shown

 


Condition Summary

Console Cosmetics: Both upper and lower console units remain in very good cosmetic condition with normal signs of prior professional use. No major dents or structural damage noted during inspection.

Mobile Cart Condition: Included rolling medical cart remains structurally stable and functional. Front accessory basket and foldable side tray are installed.

Tray / Handle Advisory:Pull handle for the accessory tray shows a slight bend. Buyer should review images carefully.

Rear Cover Advisory: Rear argon cylinder cover is missing one retaining screw. This does not affect system functionality.

Labels & Markings: Manufacturer labels, warning labels, and inspection stickers remain present as shown in images.


Functionality / Testing Summary

Power-On Testing: System powers on successfully, passes self-test sequence, and reaches standby / active operational mode.

Footswitch Response: Included dual foot pedal responded appropriately during testing.

Handpiece Activation: Hand instrument activation commands were recognized and responded to by the electrosurgical unit during testing.

Patient Pad Status: System displays patient pad warning/fault when return electrode is not connected, which is expected behavior during bench testing without pads attached.

Argon Functionality: Device was not tested with argon gas supply connected.

Operational Modes: CUT, COAG, and associated electrosurgical operational modes responded appropriately during testing.

Preventive Maintenance Status: No current PM documentation is available. Unit has not been labeled as patient-ready. Biomedical inspection and preventive maintenance are recommended prior to clinical use.


What Is Included

  • USMI SS-200E Electrosurgical Unit
  • USMI Argon 2 Plasma Coagulator
  • Rolling Medical Cart
  • Dual Footswitch Pedal
  • Argon Tank Hose Assembly
  • Patient Pad Adapter Cable
  • Foldable Side Tray
  • Front Accessory Basket / Tray
  • Hospital-Grade Bifurcated Power Cord Assembly
  • Items shown in images

What Is Not Included

  • Argon Gas Cylinder / Tank
  • Argon Tank Accessories / Regulators
  • Bipolar Instruments
  • Handpieces / Surgical Instruments
  • Patient Pads / Disposables
  • Consumables or Sterile Accessories
  • User Manual
  • Additional Accessories Not Shown

Buyer Advisory Note

This system was tested for basic operational functionality only as described above. Full clinical testing was not performed. Buyer is responsible for confirming compatibility, installation requirements, operational suitability, and biomedical certification prior to patient use.

Shipping Note

 

Due to size and configuration, system may require freight or oversized shipping service depending on destination. Buyer may arrange their own carrier if preferred.

Stock ID: 39376 (P.O. 2025) (WH 333) 

Purchase Terms & Buyer Protections

Condition & Use Notice

Condition: Overall, cosmetic, and functional condition are described in the listing above; please review all images carefully.
Functionality: Sold as described in the listing, or untested if stated. Biomed evaluation is recommended where applicable.
Included: Only items shown in photographs or specifically stated in the listing are included.
Buyer Responsibility: Buyer is responsible for verifying compatibility, suitability, and obtaining inspection, calibration, maintenance, or service as appropriate prior to use.