Dilon Navigator 2.0 Gamma D...
Dilon Navigator 2.0 Gamma Detection System W/ Angled Probe, Stand, Charger~39515
Item specifics
- Used
- Model
- Navigator 2.0
MPN- N2-9800-00
Product details
Manufacturer | Dilon Technologies |
Item: | 2015 Dilon Navigator 2.0 Gamma Detection System W/ Angled Probe, Stand & Charger Dock |
Model/Cat # | Navigator 2.0 | Ref N2-9800-00 |
Serial No. | N201511278 |
Made In: | USA |
Date of Manufacture: | 2015 |
Short description:
The Dilon Navigator 2.0 is a compact gamma detection system designed for lymphatic mapping and intraoperative localization procedures. This listing includes the Navigator console, angled gamma probe, interface cable, one rechargeable battery, charger dock (non-functional, see notes), AC adapter, mounting clamp, and a PolyMax / GCX rolling stand. The system powers on, passes self-test, and responds properly to user inputs.
Software Version: SW N2-5802-17 R5
Condition:
Console
- Overall Condition: Very Good
- Housing is intact with no cracks or structural damage
- Minor cosmetic wear consistent with normal prior clinical use
- Front display window is clear and legible
- All labels and markings are present and readable
Probe & Cables
- Probe and cable show normal cosmetic wear
- No cuts, tears, or exposed wiring noted
Stand
- PolyMax / GCX rolling stand is structurally sound
- Basket, handle, and casters intact
Console Functionality
- Device powers on successfully and passes internal self-test
- LCD display illuminates properly and shows numeric indicators (e.g., DM111, Technician 99, 511 keV, 1125)
- Display segments appear complete with no missing digits observed
- All front-panel buttons respond correctly
- Rotary volume control knob turns smoothly and volume adjustment functions properly
- Audible feedback responds during operation
- No error messages observed during testing
Probe Functionality
- Angled probe connected and recognized by the console
- Signal response observed during testing
- Probe appears operational based on functional checks performed
⚠ Calibration / PM Disclosure:
- No calibration or preventive maintenance (PM) has been performed by us
- Calibration and PM are recommended prior to clinical use
- Manufacturer: Dilon Technologies
- Probe Type: Angled Gamma Probe
- Serial Number: R3861
Interface Cable:
- Manufacturer: Dilon Technologies
- Reference Number: GP-4001-00
- Connector Configuration: Device-side > Multi-pin male | Probe-side > Multi-pin female
- Cable jacket intact with no visible damage
Battery Information:
- Battery Type: Lithium-Ion Rechargeable
- Reference Number: N2-8500-00
Specifications:
10.8V 8.7Ah 93Wh
Battery Status:
- One (1) battery included
- Battery powers the device during testing, CHARGE OVERNIGHT BEFORE USE
Charger / Power Components:
- Charger Dock Reference: N2-8000-02
- AC Adapter Model: ATS065-P240
- Power Cord: Included
⚠ Important Charger Disclosure:
- The charger dock charging pin at the rear is loose
- Battery charging is intermittent
- Charger dock is being sold as non-functional unless repaired
- The affected pin has been circled in BY marker for identification - SEE IMAGES
Stand / Mounting System:
- Manufacturer: PolyMax / GCX Corporation
- Type: Rolling equipment stand
- Includes: Device mounting clamp
- Stand is stable with smooth-rolling casters
- Dilon Navigator 2.0 Console
- Dilon Angled Gamma Probe (SN: R3861)
- Dilon Interface Cable (REF: GP-4001-00)
- (1) Dilon Lithium-Ion Battery (REF: N2-8500-00)
- Dilon Charger Dock (REF: N2-8000-02) (non-functional, see notes)
- AC Adapter ATS065-P240 with power cord
- Device mounting clamp
- PolyMax / GCX rolling stand
- Additional batteries
- Replacement charger dock
- Consumables or disposables
- Sterile covers
- User manuals
- Original manufacturer packaging
For international shipments, we also offer custom crating for a flat fee of $300 to provide added protection during transit.
Please feel free to reach out if you’d like a shipping quote or have any questions — we’re happy to help coordinate the best option for your needs.
*Items shown in photos are the items that will ship. If it is not shown in the photos, it is not included*
Stock ID : 39515 (P.O 2022) (WH104)
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition: USED, please refer to images for cosmetic condition.
- 1. Overall Condition: As seen in images - Good
- 2. Physical Condition: Please review images before bidding - Good
- 3. Working Condition: Has been tested at our end & is in good functionality...Will receive item as pictured………(offered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)