2011 Grason-Stadler AM 282 ...
2011 Grason-Stadler AM 282 Clinical Audiometer W/ Headphones (TESTED) ~ 38441
Item specifics
- Used
- Model
- AM 282
MPN- 28200
Product details
Manufacturer | Grason-Stadler |
Item: | 2011 Grason-Stadler AM 282 Clinical Audiometer W/ Headphones |
Model/Cat # | AM 282 | Ref 28200 |
Serial No. | GS18988 |
Made In: | USA |
Date of Manufacture: | 2011 |
Voltage: See below
Short Description:
Grason-Stadler AM 282 Clinical Audiometer, battery-operated and tested working. Unit was tested across multiple frequencies and decibel levels with proper response on both right and left channels. Includes MAICO headphones and interface cables. External power input port is damaged; battery operation only.
Standards Compliance:
- UL 60601-1
- CAN/CSA C22.2 No. 601.1-M90
- IEC 60601-1
Certifications: CE 0344, ETL Listed (3145885)
Power Requirements:
- AA x5 batteries (Alkaline 1.5V or Rechargeable 1.2V NiCd/NiMH)
- External AC adapter supported by design but not functional on this unit
- Device housing is structurally intact
- No cracks or dents noted
- May show minor cosmetic scratches/scuffs consistent with normal clinical use
- Display screen is clear and bright
- Battery compartment is clean and intact; battery door included
- Right-side frequency (Hz) control knob is black, while the left dB HL knob is gray
- This appears to be a cosmetic variation/replacement only and does not affect functionality
Functionality / Testing Summary:
- Device was powered using AA alkaline batteries
- Unit powers on and functions normally
- Audiometer was tested at multiple frequencies (Hz) and multiple intensity levels (dB HL)
- Right and left channels both respond accurately
- Output was verified using connected headphones
- Frequency selection and decibel adjustment respond smoothly
- All tested controls function as expected
External DC power/charging port is broken and non-functional
Unit cannot be powered via AC adapter
Battery operation only
- Last Calibration Date: 05/2018
- Next Calibration Due: 05/2019
What Is Included:
Grason-Stadler AM 282 Audiometer (main unit)
MAICO headphones with:
Red and blue ear cups
Integrated interface cable (approx. 8 ft; no cuts or tears observed)
Additional black interface/audio cable
Battery compartment cover
What Is Not Included:
- External AC power adapter (not included and not usable due to damaged port)
- Patient response/clicker button
- User manual
- Storage or carrying case
- Any consumables or disposables
- Any accessories not shown in the images
Buyer Advisory Note:
- External DC power/charging port is damaged and non-functional
- Unit is battery-powered only
- Calibration is out of date
- Buyer is responsible for calibration, verification, and regulatory compliance prior to patient use
- Intended for professional, clinical, educational, or research environments
Shipping Note:
- Unit will be securely packaged to protect the display, controls, and connectors
- Batteries will not be included for shipping safety
*Items shown in photos are the items that will ship. If it is not shown in the photos, it is not included*
Stock ID : 38441 (P.O ?) (R3 C20) - SHIPPING READY
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition: USED, please refer to images for cosmetic condition.
- 1. Overall Condition:- As seen in images - Very Good
- 2. Physical Condition: Please review images before bidding : Good
- 3. Working Condition: Has been tested at our end & is in good functionality...will receive item as pictured ……………(offered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)
