GE Corometrics 0128 Fetal M...
GE Corometrics 0128 Fetal Monitor W/ US+TOCO Transducers & NIBP SpO₂ Leads~38284
Item specifics
- Used
- Model
- 0120 Series
MPN- 0128AANO26
Product details
Manufacturer | GE Corometrics |
Item: | GE Corometrics 0128 Maternal/Fetal Monitor W/ US+TOCO Transducers & NIBP SpO₂ Leads |
Model/Cat # | 0120 Series / 0128AANO26 |
Serial No. | 13000327 |
Made In: | USA |
Date of Manufacture: | 2001 |
Voltage: 100–240V AC, 50/60 Hz
Short description:
The GE Corometrics 0128 Maternal/Fetal Monitor is a reliable system for antepartum and intrapartum fetal and maternal assessment. The unit supports Ultrasound, TOCO, NIBP, SpO₂ (Nellcor type), and FECG (no MECG). Device powers ON, passes internal self-test, and all tested parameters are functioning normally. Cosmetics show normal wear, printer is installed and working.
Condition:
- LCD Display: Bright and scratch-free
- Printer: Installed and working (paper not included)
- Trim Knob: Intact and functional
- Softpads / Buttons: Fully responsive
- Housing: No dents or cracks; cosmetic scuffs and paint loss present
- Ports: J101, J102, J103, J109, J110, J111, Remote, ECG, Leg Plate Tester
- Telemetry Transmitter: Not included
- Self-Test: Passed
- Errors: None reported
- Overall Cosmetics: Good, standard clinical wear
- Ultrasound (FHR): Working with both GE-Compatible 5700HAX transducers
- TOCO: Functional with GE-Compatible 2264HAX
- NIBP: Inflation/deflation cycles tested with included hose & cuff
- SpO₂ (Nellcor type): Adapter INCLUDED and TESTED — stable waveform and proper detection
- FECG
- Display stable with no flicker
- Printer feeds and prints correctly
- All menus, keypad, rotary knob responsive
- All ports intact and recognized
Monitor & Accessories:
- (1) GE Corometrics 0128 Maternal/Fetal Monitor
- (1) NIBP Hose (REF SH3931D)
- (1) New Adult NIBP Cuff (REF SC1721-3232)
- (1) Power Cord
Transducers:
(2) GE Compatible 5700HAX Ultrasound Transducers (10 ft cables)
Tear-free insulation
Function-tested
(1) GE Compatible TOCO Transducer (REF 2264HAX, 10 ft cable)
Strain relief intact
SpO₂
- (1) Nellcor-compatible SpO₂ Adapter Cable — Tested
- (1) New Reusable SpO₂ Finger Sensor (Adult)
- FECG wire
- Abdominal belts
- Event clicker
- Telemetry transmitter
- Mobile cart / stand
- Printer paper
- User manual
Ships in a 25 × 25 × 20 inch box, approx. 40 lbs.
Buyer may provide their own shipping label.
Expedited and freight options available.
Advisory Note:
This device is not labeled patient-ready. A full inspection and/or preventive maintenance (PM) is recommended before clinical use.
Unit passes all tested functions and shows normal cosmetic wear.
*Items shown in photos are the items that will ship. If it is not shown in the photos, it is not included*
Stock ID : 38284 (P.O 2014) (WH104 C5)
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition: USED, please refer to images for cosmetic condition.
- 1. Overall Condition: As seen in images - Very Good
- 2. Physical Condition: Please review images before bidding - Very Good
- 3. Working Condition: Has been tested at our end for powers on, following commands therefore seems functional to us.....Will receive item as pictured…………(Offered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)