2010 Viasys Infant Flow SiPAP Ventilator P/N 675-CFG-005 W/O Accessories ~ 36431
Item specifics
- For parts or not working
- Model
- 675-CFG-005
MPN- 675-CFG-005
Product details
Manufacturer | Viasys |
Item: | 2010 Viasys Infant Flow SiPAP Ventilator P/N 675-CFG-005 W/O Accessories |
Model/Cat # | 675-CFG-005 |
Serial No. | BAN01625 |
Made In: | USA |
Date of Manufacture: | June-2010 |
Voltage: 110–120V / 220–230V | 50–60 Hz | 50VA
Short description...
*Sale is for imaged items only.
*Signs of average use.
*PARTS ONLY SALE.
*System Type: Infant non-invasive ventilatory support (SIPAP)
*Power Input:
-100-120V/220-240V, 50/60 Hz
-Fuse: 2.5A (T) 250V
-Power Switch: Toggle ON/OFF
*Gas Requirements:
-Air and O. input pressure: 40-90 PSIG/280-600 kPa
-Minimum Flow: 20 LPM at 40 PSIG
*Pressure Controls:
-NCPAP / Pressure Low: 0-8 L/min flow meter
-Pressure High: 0-6 L/min flow meter
-Oxygen Concentration Dial: Adjustable from 21% to 100%
*Ports:
-Front: XDCR (Transducer port), PH/UX port
-Rear: AIR and O, input fittings (one connector is missing)
*Certifications:
-ETL Listed (UL STD 2601-1)
-CAN/CSA STD C22.2 No. 601.1
-CE Marked
*Safety Warnings:
-Water in air can cause malfunction
-Explosion Hazard: Do not use with flammable anesthetics
*Condition Report:
-Unit boots up, goes through the initial screen, raeches NCPAP10 & alarm state
-Displayed Error:
Error Code E50
*Loud alarm beeps with red LED warning
Read Manual” and “Attach Sensor” prompts displayed
Sensor icon shows "attach sensor" (Not Included)
*Physical Condition:
-All knobs & flow meters are intact
-Front LCD screen is cracked, but still partially displays input
*Following are NOT included
-Sensors/Transducers
-Accessories
-Tubings
-Manual
-Rolling Stand
*Please review images and check for compatibility before bidding for the item
NO RETURN, REFUND OR EXCHANGE OPTION FOR PRODUCTS LISTED UNDER "PARTS OR NOT WORKING" CATEGORY
Package includes:-
2010 Viasys Infant Flow SiPAP Ventilator P/N 675-CFG-005
*Items shown in photos are the items that will ship. If it is not shown in the photos, it is not included*
Sterilized : Non-sterile device
Manual : Not included
Cleaned : Yes, at our facility
Shipping Weight : 20 lbs
Stock ID : 36431 (P.O 2017) (SC 5)
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition: Parts Only, please refer to images for cosmetic condition.
- 1. Overall Condition:- As seen in images - Parts Only
- 2. Physical Condition: Please review images before bidding : Poor
- 3. Working Condition: Parts Only...will receive item as pictured ……………(offered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)