Thermo Electron Sorvall Model CW2 Cell~ 37457
Item specifics
- For parts or not working
Product details
Manufacturer | Thermo Electron Corporation |
Item: | Thermo Sorvall CW2+ Cell Washing Centrifuge ONLY |
Model/Cat # | CW2+ |
Serial No. | 045310240 |
Made In: | USA |
Date of Manufacture: | 2006 |
Voltage: 100/120V~ 50/60Hz – 5A T | 220/230/240V~ 50/60Hz – 2.5A T
Short description:
Pre-owned Thermo Sorvall CW2+ Cell Washing Centrifuge offered for parts or repair. Device powers on and front panel is responsive. The lid fails to open despite visible "LID OPEN" indicator and troubleshooting efforts. No rotor or buckets included. Internal bowl and calibration pump appear to be in good shape.
Condition Summary:
- Cosmetic: Very good overall; no cracks or dents observed. Some surface scratches and scuffs from prior use. ONE SCREW IS MISSING ON THE LEFT SIDE ABOVE THE TIMER LCD.
- LCD Display: Bright and functional.
- Touchpad: Responsive; soft keys intact, no tears or visible damage.
- Tubing & Pump: Device includes connected calibration pump tubing and hospital-grade power cord.
- Lid: Lid opening mechanism is faulty. Lid was mechanically opened from the rear for inspection.
- Rotor/Buckets: Not included. Unit does not contain Cat. #477 rotor or any associated accessories.
- Accessories: Power cord and fluid tubing are included. No user manual, no buckets, no tubes, and no other accessories are included.
Functionality Summary:
- Powers on
- Control panel lights up
- Lid opening mechanism not functioning (MANUALLY OPENED FROM THE BACK AFTER UNSCREWING )
- No rotor detected
- Calibration pump functional
- Offered strictly as-is for parts or repair
Front Panel Description:
The front control panel features:
- Numeric keypad
- Indicator lights (Power, Check, Lid, etc.)
- Function buttons (Wash, Spin, Agitate, Calibrate, CE, Infinite Loop)
- Timer and status LEDs
Warnings and Cautions Noted on Device:
Rear Panel Warnings:
“WARNING: For continued protection against risk of fire, replace only with fuse of same type & rating.”
“Electric shock hazard in this compartment. Refer servicing to qualified personnel.”
Pump Compartment Warning:
“Electric shock hazard in this compartment. Refer servicing to qualified personnel.”
Top Lid Warning:
“CAUTION: Do not operate with an unbalanced load.
Do not run saline pump without rotor and plunger in place.
Do not get liquid on the top of the motor. Make sure the entire length of drain tubing is lower than the bottom of the unit so that fluid does not build up in coils.
Keep inside of tubing clean and clear.”
Internal Bowl Warning:
“CAUTION: Remove this bowl for cleaning. Excessive liquid can cause corrosion of motor.”
NO RETURN, REFUND OR EXCHANGE OPTION FOR PRODUCTS LISTED UNDER "PARTS OR NOT WORKING" CATEGORY
Package includes:
Thermo Sorvall CW2+ Cell Washing Centrifuge
Calibration pump tubing
Hospital-grade power cord
*Items shown in photos are the items that will ship. If it is not shown in the photos, it is not included*
Sterilized : Non-sterile device
Manual : Not Included
Cleaned : Yes, at our facilty
Shipping Weight : 40 lbs
Stock ID : 37457 (P.O 2017) (WH105 444)
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition: Parts Only, please refer to images for cosmetic condition.
- 1. Overall Condition: As seen in images : AS-IS | For Parts
- 2. Physical Condition: Please review images before bidding : Good
- 3. Working Condition: PARTS ONLY SALE / The lid fails to open despite visible "LID OPEN" indicator and troubleshooting efforts...Will receive item as pictured …………(Offered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)
- 6. Caution for Buyers:
DESPITE WHAT MAY BE WRITTEN IN THIS LISTING ALL ITEMS ARE SOLD 'AS IS' & 'WHERE IS' AND UNLESS THE SELLER HAS INDICATED OTHERWISE, THERE WILL BE NO REFUND.
Please make sure you are ready to buy if you decide to place a bid.
Available Documentation (manual etc.): nil
Accessories: Comes with everything you see in pictures nothing more nothing less.
Added note: Completely check out item/s prior to use in conjunction with patient care and seller will not take any responsibility for its use on patient.
Maintenance & Certification: - Strongly recommended.
Useful tips: do not scratch or apply sticking plasters.
Seller does not fix or repair any items to make them usable.
If item is listed for parts only, it is specifically mention in the listing as well.