For orders, please call: 1-952-953-0653

$0Checkout 0 Item(s)

MENU

    

IRIS M401-22 Statspin CenSl...

IRIS M401-22 Statspin CenSlide® 2000 Centrifuge (Urine Sediment Analysis) 10079

Item specifics

Condition:Used : 
Seller Notes:Smooth and vibration free spinning
Brand:

Iris

MPN:

M401-22

Model:

Iris Statspin CenSlide® 2000

More details


$436.00

10079

Availability: Item Available

1 item in stock

Warning: Last item in stock!

Add to cart

Place an offer

Product details

Vendor

 

IRIS International Inc.

Item

 

 Statspin CenSlide® 2000 Centrifuge Urine Sediment Analysis System

Model/Cat#

 

 M401-22

Serial #

 

150M40102007

Voltage

 

24VDC, 1.7A

Made In:

 

USA

Specifications

 

  • Speed/Force
    1,350 rpm / 97 xg
    Cycle Time
    Less than 60 seconds
    Capacity
    6-place rotor
    Accell Time
    15 seconds to 95% of speed
    Regulatory
    UL Marked
    Warranty
    1 Year
    Power
    24VDC 1.7A (wall adapter incl.)
    Dimensions
    5.6" H x 11.4" W x 12.9" D

DOM:

 

NA


Sterile: NO

Manual : No

No tubes with the system

AC adapter included (new)

Balance tube included 

Last PM : 3/2014

Start soft button rubber is degenerated 

Shipping weight : 15 pounds

 

Stocks ID: 10079 (R2C1)

Comments:

It’s a used item, expect some wear and tear!!!!!!!!!!!!!!!

Kindly enlarge the images and see them with zooming.

Concern or query: Ask a Question

Condition:

Overall Condition:   As seen in images / Good

Physical Condition:   Kindly see all images before bidding - the touch start pad is  worn out

Working Condition:  Powers up and spins well with out vibrations.  (Not tested with tubes or samples) 

As a whole, the unit has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS!

Biomed check is strongly recommended before use

Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)

 Available Documentation (manual etc.): nil

Accessories: Comes with everything you see in pictures nothing more nothing less.

Added note:  Completely check out item/s prior to use in conjunction with patient care and seller will not take any responsibility for its use on patient.

Maintenance & Certification: - Strongly recommended.

Useful tips: do not scratch or apply sticking plasters.

Added Comments: 

Seller does not fix or repair any items to make them usable.

If item is listed for parts only, it is specifically mention in the listing as well.

text/x-generic footer.tpl ( UTF-8 Unicode text )