Hologic Sahara Bone Sonometer w Power Supply & Case QC Failed Parts Repair~40116

Item specifics

Condition
For parts or not working
Seller Notes
“Pre‑owned Hologic Sahara Clinical Bone Sonometer (Model SAHARA, S/N 02281, DOM 1999, Software v2.14, USA) with Jerome Industries WSZ301MS V3 power supply, power cord, user guide, and maroon rolling case."
Model
SAHARA
MPN
See Below

More details


$455.20

40116

1 item in stock

Warning: Last item in stock!

Add to cart

Place an offer

Product details

Hologic Sahara Clinical Bone Sonometer w/ Power Supply, Manual & Rolling Case 

Item Overview

Pre-owned Hologic Sahara Clinical Bone Sonometer with power supply, power cord, user guide, and maroon rolling case. Unit powers on, initializes, and the internal self-test PASSED. An attempted QC phantom test FAILED; QC/calibration verification is recommended before clinical use. No patient/clinical testing was performed.

Device Information

  • Manufacturer: Hologic
  • Model: SAHARA        Serial: 02281
  • DOM: 10/04/99           Software: v2.14
  • Product: Bone Sonometer
  • Electrical Rating: +12V <1.5A / +5V <4A / –12V <0.5A
  • Made In: USA             Type: BF • IPX0

Power Supply

  • Manufacturer: Jerome Industries
  • Model: WSZ301MS V3
  • Input: 100–250V AC
  • Outputs: +5V / +12V / –12V DC

Condition Summary

  • Housing: Great used condition; normal scratches/scuffs
  • LCD: Bright, clear, and responsive
  • Controls: Soft-pad buttons intact and responsive
  • Transducer/Pad Assemblies: Present
  • Printer Compartment: Present; paper not included
  • Rolling Case: Normal wear; zippers, pull handle, and wheels functional

Functional Testing

  • Powers on and initializes
  • Software v2.14
  • Internal self-test PASSED
  • Menus, prompts, date/time, and language settings responsive
  • Reaches “Ready – Press ON” stage
  • One QC phantom test attempted — FAILED
  • System calibration NOT performed
  • No clinical/patient measurements performed
  • No recent PM/calibration documentation

QC / Calibration Advisory

The attempted QC phantom test did not pass. The cause was not determined. QC verification and calibration/service as necessary are recommended before clinical use.

Included

  • Hologic Sahara Bone Sonometer
  • Jerome Industries Power Supply
  • Power Cord
  • Maroon Rolling Case
  • User’s Guide
  • Sahara exam papers shown
  • Installed transducer/pad assemblies

Not Included

QC Phantom • Positioning Aid • Coupling Gel • Printer Paper • Consumables • Calibration/PM Certification • Any Accessories Not Pictured

Buyer Advisory

Pre-owned medical equipment tested only as described. Internal self-test PASSED; attempted QC phantom test FAILED. No patient testing or system calibration was performed. Buyer is responsible for inspection, QC/calibration verification, and determining suitability before use. Sale includes only the pictured items.

Stock ID: 40116 (P.O. 2026) (WH104)

Purchase Terms & Buyer Protections

Condition & Use Notice

Condition: Overall, cosmetic, and functional condition are described in the listing above; please review all images carefully.
Functionality: Sold as described in the listing, or untested if stated. Biomed evaluation is recommended where applicable.
Included: Only items shown in photographs or specifically stated in the listing are included.
Buyer Responsibility: Buyer is responsible for verifying compatibility, suitability, and obtaining inspection, calibration, maintenance, or service as appropriate prior to use.