Chattanooga MP-1 Triton Traction Machine | Rope & Pulley | NEEDS REPAIR ~ 38601

Item specifics

Condition
Used
Seller Notes
“During inspection, the device was found to have a mechanical issue in the release/rest cycle caused by a gearing fault. The traction pull is normal, but the release phase drops abruptly and requires repair before any therapeutic use.”
Model
MP-1
MPN
Does Not Apply

More details


$214.40

38601

1 item in stock

Warning: Last item in stock!

Add to cart

Place an offer

Product details

Device Information

Manufacturer: Chattanooga Corporation
Model: MP-1 (Triton Traction Machine)
Chattanooga Part No.: 65202C
Serial Number: 5167
Power Requirement: 120 V AC ±10%, 50/60 Hz, 1.0 A (Max)
Fuse: 1 A, 250 V, SLO-BLO
Country of Manufacture: USA

Warning Labels:

  • Caution – Risk of fire: replace fuse as marked

  • Push for rope release only with power off

  • Danger – explosion hazard: do not use near flammable anesthetics

  • For hospital or clinical use only


Short Description

The Chattanooga MP-1 Triton Traction Machine is a clinical-grade spinal traction system used for cervical and lumbar decompression therapy. It offers programmable static or intermittent traction with digital LED displays and powered traction-force delivery.

During inspection, the device was found to have a mechanical issue in the release/rest cycle caused by a gearing fault. The traction pull is normal, but the release phase drops abruptly and requires repair before any therapeutic use.


Condition Summary

Overall Condition: Used – Fair, functional but requires mechanical repair.

Cosmetics

  • No cracks or structural damage

  • Moderate scuffs and paint wear from use

  • All labels intact and legible

Operational Findings

  • Power-On: Unit powers up normally and passes self-check

  • Display: LED panels bright and clear

  • Keypad: All buttons and keys responsive

  • Traction Pull: Normal pulling force; rope extends/retracts correctly

  • Release Phase: Fault present – the rest/release cycle skips and drops abruptly, consistent with worn internal gearing

  • Repair Need: Estimated ~$400 to rebuild/replace internal gearing for proper smooth cycle operation

  • Audible Alarm: Tone present due to missing patient safety switch (expected in this condition)

Accessories Included

  • Hospital-grade power cord

  • Integrated rope-and-pulley assembly with hook

Missing

  • Patient safety switch

  • User/service manual

  • Traction table/table mount

  • Calibration or PM records

  • Any other items not shown


Functionality Summary - NEEDS REPAIRS - NO RETURNS 

Working Functions

  • Powers on successfully

  • Control panel fully responsive

  • Timer, force, hold/rest, and cycle parameters adjust correctly

  • Rope pull verified

Not Working Properly

  • Release/rest phase is defective

  • Abrupt drop during release cycle

  • Internal gearing requires repair before any clinical use

Testing Level: Power-on and control-response testing only. No load or patient-weight testing performed.


Included

  • Chattanooga MP-1 Triton Traction Machine (S/N: 5167)

  • Rope & pulley mechanism with hook

  • Hospital-grade power cord

Not Included

 

  • Patient safety switch

  • User/service manual

  • Traction table

  • PM or calibration documentation

  • Any accessories not shown

*Items shown in photos are the items that will ship.  If it is not shown in the photos, it is not included*

 

Stock ID : 38601 (P.O 2019) (SC 6)

 

Comments:

Kindly enlarge the images and see them with zooming.

Concern or query: Ask a Question

Condition: USED, please refer to images for cosmetic condition.

  1. 1.    Overall Condition: As seen in images - AS IS 
  2. 2.    Physical Condition: Please review images before bidding - Good
  3. 3.    Working Condition: READ FUNCTIONALITY NOTES ABOVE .Will receive item as pictured……………(Offered AS IS)
  4. 4.    As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
  5. 5.    Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)