Philips IntelliVue MP50 M8004A X2 CO2 BIS C.O. Recorder Monitor Tested ~ 40796

Item specifics

Condition
Used
Seller Notes
“Pre-owned Philips IntelliVue MP50 M8004A Patient Monitor with IntelliVue X2 M3002A, M3015A CO₂ extension, M1012A cardiac output module, M1034A BIS module, M1116B recorder, and patient accessories.MP50 is in very good cosmetic condition with a bright display."

More details


$1,099.20

40796

1 item in stock

Warning: Last item in stock!

Add to cart

Place an offer

Product details

Philips IntelliVue MP50 M8004A Patient Monitor w/ X2, CO₂, BIS, C.O. & Recorder

Item Overview

Philips IntelliVue MP50 multiparameter patient monitoring system with IntelliVue X2 M3002A installed in place of the standard MMS, Microstream CO₂ extension, cardiac output module, BIS module, recorder, and patient monitoring accessories.

ECG, NIBP, SpO₂, and temperature tested. Main monitor is in very good cosmetic condition with a bright, clear display and responsive controls.

Device Information

MP50 Main Monitor

Model: M8004A | S/N: DE44026202
DOM: 03/2006 | Made In: Germany
Software: K.21.42 | Config P/N: S-M8003-1601A
Options: H40, A06, C01, C05, C15, C20, C31
Power: AC Operated, Non-Battery Variant

IntelliVue X2 Installed Measurement Monitor

Model: M3002A | S/N: DE46685821
Software: M.04.05-19 | Options: C00, C01, C13, C15, C20
Parameters: ECG, NIBP, SpO₂, Temperature
Battery: Philips M4607A Rechargeable Li-Ion
Rating: 11.1V, 1600mAh / 17.7Wh

Installed Modules

  • M3015A Microstream CO₂ Extension: S/N DE43525842 | Option C06 | DOM 04/2007 | Germany

  • M1012A Cardiac Output Module: S/N 3618A20773 | Option ABA | USA

  • M1034A BIS Module: S/N DE11007634 | DOM 05/2006 | Germany

  • M1116B Recorder: P/N M1116-80000 | S/N 4227A49018 | DOM 07/2006 | USA

Condition & Inspection

  • MP50 is in very good cosmetic condition with normal handling wear; no significant cracks or dents observed.

  • Main LCD is bright and clear; touchscreen, softkeys, and rotary trim knob are responsive.

  • X2 powers on with a clear, responsive display. Localized housing crack near the upper corner and battery-release area, as pictured.

  • X2 rechargeable battery included; battery runtime and health unknown.

  • Adult, pediatric, and neonatal monitoring profiles, multiple screen layouts, and built-in calculation menus accessible.

Functional Testing

Tested

  • ECG: Waveforms and heart-rate readings displayed.

  • NIBP: Blood pressure measurement obtained.

  • SpO₂: Nellcor OxiMax-compatible reading and pleth waveform displayed.

  • Temperature: Measurement displayed using skin temperature probe.

  • X2: Powered on; display and basic controls are responsive.

Recognized / Not Functionally Tested

  • BIS module

  • Cardiac output module

  • Recorder module / printing

Additional Functions Not Tested

  • Microstream CO₂

  • IBP

No calibration, measurement accuracy verification, or electrical safety testing was performed.

Included

Equipment

  • Philips IntelliVue MP50 M8004A Patient Monitor

  • Philips IntelliVue X2 M3002A with M4607A Battery

  • M3015A Microstream CO₂ Extension Module

  • M1012A Cardiac Output Module

  • M1034A BIS Module

  • M1116B Recorder Module

Patient Accessories - NEW 

  • ECG Trunk Cable with 5-Lead ECG Lead Set

  • Single-Tube NIBP Hose with Adult Cuff (25–35 cm)

  • SpO₂ Extension/Adapter Cable with Reusable Adult Sensor

  • IBP Adapter Cable (No Transducer)

  • Skin Temperature Probe

  • Hospital-Grade AC Power Cord

Not Included

M3001A MMS, BIS accessories, cardiac output accessories, CO₂ sampling accessories, IBP transducer, recorder paper, stand/cart, user manual, additional disposables, or consumables.

The actual monitor, modules, cables, and accessories pictured are the items supplied.

Buyer Advisory

ECG, NIBP, SpO₂, and temperature tested. BIS, C.O., CO₂, IBP, and recorder functions remain unverified. X2 has a localized housing crack; battery health is unknown. Professional inspection and testing are required before clinical use.

Stock ID: 40796 (P.O. 4014) (R3 C15) 

Purchase Terms & Buyer Protections

Condition & Use Notice

Condition: Overall, cosmetic, and functional condition are described in the listing above; please review all images carefully.
Functionality: Sold as described in the listing, or untested if stated. Biomed evaluation is recommended where applicable.
Included: Only items shown in photographs or specifically stated in the listing are included.
Buyer Responsibility: Buyer is responsible for verifying compatibility, suitability, and obtaining inspection, calibration, maintenance, or service as appropriate prior to use.