Philips IntelliVue MP70 M80...
Philips IntelliVue MP70 M8007A SYSTEM w M3001A MMS M1116B Recorder & Leads ~ 40161
Product details
Manufacturer | Philips Healthcare |
Item: | 2008 Philips MP70 Neonatal Monitor – MMS Module, Recorder Module & Leads |
Model/Cat # | MP70 / M8007A / |
Serial No. | DE73166550 |
Made In: | Germany |
Date of Manufacture: | 01-2008 |
Voltage: 100-240V 50-60Hz 1.8-1.0A
Short description:
*Sale is for imaged items only.
*Signs of moderate use.
*Has been tested at our end & is in good functionality as shown in the images.
*Sale comprises of:
-Intellivue MP70 (M8007A) Patient Monitor
-Ref M3001A MMS Module
-Ref M1116B Recorder Module
-Patient Leads
*Modules:
-1X M3001A MMS Module | Ref 862442 | SN# DE717M4844 | DOM: 2008-01 [Opt: A01C06] | Latch is broken
-1X M1116B Recorder Module | SN# 4227A62440 | DOM: 2008-07
*Software: J.10.52
*Options: H20, A06, C01, C02, C04, C05, C09, C15, C20
*Battery: Not Installed
*Parameters: Temp, NBP, SpO2 (Nellcor), ECG & IBP
*Printer: Installed
*LCD: In good shape, touchscreen is responsive; scratch-free
*Dents/Cracks: Yes noted; See images
*Scratches/Scuffs:Yes; see images
*Softpads: Working | Worn out
*Trim knob: Intact | Worn out
*Date & Time: Date is correct, time can be adjusted as per the time zone
*Patient Leads: (New | DOM: 2026)
-SpO2 Reusable sensor Type Nellcor Ref SP9325A
-ECG Cable W/ Leads Ref SG5124S
-Ref SH0910S NBP Hose W/ Cuff SC1711-11
-IBP Adapter Cable Ref SB0411
-Temp Probe Ref ST1305
*No IBP transducer included
*Disposables or consumables: N/A
*Power Cord: Included
*Stand: Not Included
*Manual: Not Included
*Please review images and check for compatibility before buying.
Package includes:
2008 Philips MP70 Neonatal Monitor
M3001A MMS Module | Ref 862442
M1116B Recorder Module
SpO2 Reusable sensor Type Nellcor Ref SP9325A
ECG Cable W/ Leads Ref SG5124S
Ref SH0910S NBP Hose W/ Cuff SC1711-11
IBP Adapter Cable Ref SB0411
Temp Probe Ref ST1305
Power Cord
*Items shown in photos are the items that will ship. If it is not shown in the photos, it is not included*
Stock ID : 40161 (P.O 4014) (WH104)
Comments:
Kindly enlarge the images and see them with zooming.
Concern or query: Ask a Question
Condition: USED, please refer to images for cosmetic condition.
- 1. Overall Condition:- As seen in images - Good
- 2. Physical Condition: Please review images before bidding : Fair to good
- 3. Working Condition: Has been tested at our end & is in good functionality as shown in the images....will receive item as pictured ……………(offered AS IS)
- 4. “As a whole; the item has not been tested technically or professionally at our end- unable to test --- being sold STRICTLY AS IS! Biomed check is strongly recommended before clinical use!”
- 5. Completeness: (with everything seen in the pictures. Please look at all pictures and go through detail description before bidding.)