Lot of 2 Masimo Radical-7 Rainbow SET Monitors MX-1 | TESTED ~ 39836

Condition: Used
Notes: Lot of two Masimo Radical‑7 Rainbow SET tested with compatible docking setup. Both units powered on, acquired SpO₂/pulse readings, and allowed full menu navigation; LCDs bright and responsive, housings in very good condition with minor wear (one unit has a chipped corner).
Brand: Masimo
Model: Radical-7
Made In: USA

More details


$184.00

39836

Availability: This product is no longer in stock.

Product details

Device Profile

Manufacturer: Masimo Corporation
Item: Lot of 2 Masimo SET Radical-7 Signal Extraction Pulse CO-Oximeters
Model: Radical-7 Rainbow SET Configuration: MX-1
Serial Numbers: T029230 / T028899   
Date of Manufacture: 2009 / 2009
CE Mark: CE 0123    
Made In: USA


Short Description

Lot of two Masimo Radical-7 Rainbow SET handheld pulse CO-oximeters configured as MX-1 units. Both devices were tested using compatible Masimo docking setup with compatible SpO₂ adapter cable and sensor. Units power on properly, acquire waveform and SpO₂ readings, and allow navigation through menus and configuration settings.

Quick Condition Overview

Functional Status: Tested & Working
Cosmetic Condition: Very Good Overall
Display Condition: Bright LCDs with good visibility
Battery Status: Installed batteries are weak/dead and require replacement
Completeness: Handheld units only as shown

 


Condition Summary

Housing Condition: Both units remain in very good cosmetic condition overall with expected minor scratches, scuffs, and normal signs of careful prior use. No major dents or heavy structural damage noted.

Corner Damage: Unit S/N T028899 has a chipped corner area on the housing as shown clearly in the uploaded images. Damage appears localized and did not prevent functional testing during inspection.

Display Condition: LCD screens are bright and responsive. Touch/menu navigation areas and side soft keys responded properly during testing.

Latch & Docking Areas: Upper locking latch assemblies remain intact. Rear docking engagement areas and lower mounting sections appear structurally sound and compatible with the docking station interface.

Connector Condition: Front Masimo SET connector ports appear clean and intact without obvious bent pins or connector damage observed during inspection.


Functionality / Testing Summary

Power & Boot Testing: Both units powered on successfully through compatible Masimo RDS-3 docking configuration and completed normal startup sequence.

SpO₂ Testing: Devices successfully obtained pulse and SpO₂ readings using compatible Masimo adapter cable and sensor setup during testing.

Menu Navigation: Menu system, alarm settings, display rotation, trend screens, and configuration menus were accessed successfully.

Software Information Observed:
• Masimo SET Software: V7.8.0.1
• Handheld Software: R7.7.4.8
• D-Station (RadNet): R5.2.0.9

Additional Functions Verified:
• Alarm adjustment accessible
• Display orientation / rotate screen function operational
• Date and time adjustment accessible
• Trend display screens functional
• Button controls responsive

Battery Advisory: Both units contain installed batteries that no longer properly hold charge and should be replaced. Units may not operate independently away from docking station until replacement batteries are installed.


What Is Included

  • Qty 2 — Masimo Radical-7 Rainbow SET Pulse CO-Oximeters
  • Installed internal batteries (non-functional / weak)
  • Items shown in images only

What Is Not Included

  • Masimo RDS-3 Docking Station
  • SpO₂ adapter cable
  • Reusable or disposable sensors
  • User manual
  • Consumables or disposables
  • Additional accessories not shown

Buyer Advisory Note

These units were tested using external compatible Masimo accessories and docking configuration which are not included in this sale. Buyer is responsible for obtaining compatible sensors, cables, docking accessories, and replacement batteries as required for intended application.

Shipping Note

Units will be professionally packed and shipped from Medicka Medical, Minnesota. Batteries are installed for testing/reference purposes only and are not guaranteed due to age and normal battery wear.


Stock ID: 39836 (P.O. 5008) (WH104 SCC15) 

Purchase Terms & Buyer Protections

Condition & Use Notice

Condition: Overall, cosmetic, and functional condition are described in the listing above; please review all images carefully.
Functionality: Sold as described in the listing, or untested if stated. Biomed evaluation is recommended where applicable.
Included: Only items shown in photographs or specifically stated in the listing are included.
Buyer Responsibility: Buyer is responsible for verifying compatibility, suitability, and obtaining inspection, calibration, maintenance, or service as appropriate prior to use.